Generac Power Systems CW15 Owner'S Manual Download Page 21

Operation

Water Pump

17

Starter cord kickback (rapid retraction) can 
result in bodily injury. Broken bones, frac-
tures, bruises, or sprains could result.

6.

When starting engine, grasp starter grip handle and 
pull slowly until you feel some resistance. Then pull 
rapidly to start engine.

7.

Return starter grip handle slowly. DO NOT let rope 
“snap back” against starter.

8.

When engine starts, slowly move choke lever to RUN 
position as engine warms. If engine falters, move 
choke lever to CHOKE position, then back to RUN 
position.

9.

If engine fails to start after 5 pulls, move choke lever 
to RUN position, and repeat steps 6 through 9.

Figure 5-5. Start the ST20 Water Pump

NOTE: It is normal for the Water Pump to fluctuate 
speed while the system is self priming due to air 
pockets in the suction hose.

Contact with muffler area can result in 
serious burns. Exhaust heat/gases can 
ignite combustibles, structures or 
damage fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust 

gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (152 cm) of clearance on all sides 

of water pump including overhead.

• It is a violation of California Public Resource Code, 

Section 4442, to use or operate the engine on any for-
est-covered, brush-covered, or grass-covered land 
unless the exhaust system is equipped with a spark 
arrester, as defined in Section 4442, maintained in 
effective working order. Other states or federal jurisdic-
tions may have similar laws.

• Replacement parts must be the same and installed in 

the same position as the original parts.

5.5 — H

OW

 

TO

 S

TOP

 Y

OUR

 

WATER

 

PUMP

1.

Move throttle control lever on engine to “Low” (Turtle) 
position (Figure 5-6) (if applicable).

2.

Turn the engine ON/OFF switch to the OFF (0) posi-
tion.

3.

Turn the fuel valve to the OFF (0) position (if applica-
ble).

4.

Allow the engine to cool thoroughly.

5.

After cooling, remove the priming plug and drain plug 
from the pump casing and allow it to drain com-
pletely.

Never operate a damaged or defective pump. 
To prevent accidental starting, remove and 
ground the spark plug wire before performing 
any service.

NOTE: The owner/operator is responsible for all peri-
odic maintenance. Complete all scheduled mainte-
nance in a timely manner. Correct any issues before 
operating the pump. Improper maintenance will void 
the pump's warranty.

Figure 5-6. Throttle Position

E

D

Summary of Contents for CW15

Page 1: ...www generac com or 1 888 436 3722 Owner s Manual Water Pump Model ST20 Model Number Serial Number Model CW15...

Page 2: ...stituents are known to the state of California to cause cancer birth defects and other reproductive harm WARNING California Proposition 65 This product contains or emits chemicals known to the state o...

Page 3: ...on 15 5 2 Water Pump Location 15 5 3 Checklist Before Starting Engine 16 5 4 How to Start Your Water Pump 16 5 5 How to Stop Your Water Pump 17 Section 6 Maintenance 6 1 Maintenance Recommendations 19...

Page 4: ...iv...

Page 5: ...fore use Refer to the Assembly section of the manual for instructions on final assembly procedures Follow the instructions completely The manufacturer cannot anticipate every possible cir cumstance th...

Page 6: ...2 Water Pump This page intentionally left blank Introduction...

Page 7: ...n which if not avoided could result in minor or moderate injury NOTE Notes contain additional information import ant to a procedure and will be found within the regu lar text body of this manual These...

Page 8: ...s burns Exhaust heat gases can ignite combustibles structures or damage fuel tank causing a fire DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at leas...

Page 9: ...is filled with water before start ing the engine NEVER run pump without priming Use a non collapsible hose on the suction side of the pump Use the pump only for its intended uses 2 1 5 Hearing Protect...

Page 10: ...missing parts or without protective housing or covers DO NOT by pass any safety device on this machine DO NOT operate water pump above rated head DO NOT modify water pump in any way Before starting w...

Page 11: ...Choke Prepares a cold engine for starting J Air Filter Protects engine by filtering dust and debris out of the intake air K Recoil Starter Used for starting the engine L Engine ON OFF Switch Turn swi...

Page 12: ...General Information 8 Water Pump Figure 3 2 CW15 Features and Controls Figure 3 3 Features and Controls H I J M K L B C D A G E F Q V U T S R W X Y...

Page 13: ...ng backfiring Black exhaust smoke or high fuel consumption 3 4 HIGH ALTITUDE OPERATION The fuel system on this engine may be influenced by operation at higher altitudes 3 5 UNPACKING 1 Remove the loos...

Page 14: ...10 Water Pump This page intentionally left blank General Information...

Page 15: ...n Mounts feet Figure 4 1 A Attach the vibration mount to the frame using 2 Flange Bolts M8x40 and 2 Nuts M8 B Slide the bolts through the vibration mount and through the frame C Secure with nuts Tight...

Page 16: ...ne to run on alternate fuels To protect the fuel system from gelling mix in a fuel stabi lizer when adding fuel See Storage All fuel is not the same If you experience starting or performance prob lems...

Page 17: ...ing with a hose clamp 3 Attach the green suction hose to the green colored flange by sliding the hose over the barb and securing with a hose clamp Figure 4 7 Figure 4 7 Attach Hoses 4 Attach the filte...

Page 18: ...14 Water Pump This page intentionally left blank Set up...

Page 19: ...Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings NEVER start or run engine indoors in a vehicle or in an enclosed area EVEN if windows and do...

Page 20: ...this instruction will void warranty 5 4 1 Starting the CW15 Water Pump 1 Flip engine switch A to the ON position Figure 5 3 2 Move choke lever B to CHOKE position A For a warm engine be sure the choke...

Page 21: ...on all sides of water pump including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any for est covered brush covered or grass covered land...

Page 22: ...18 Water Pump This page intentionally left blank Operation...

Page 23: ...ar A new spark plug and clean air fil ter assure proper fuel air mixture and help your engine run better and last longer 6 2 MAINTENANCE SCHEDULE Follow the hourly or calendar intervals whichever occu...

Page 24: ...KING REPAIRS TO YOUR WATER PUMP Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO...

Page 25: ...re water pump is on a flat level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug A Figure 6 3 and...

Page 26: ...ag to wipe off the hose 3 Empty pump of all liquids Remove drain cap let drain completely replace drain cap 4 Store unit in a clean dry area 5 If storing for more than 30 days see the Long Term Storag...

Page 27: ...nkcase Refill with recommended grade See Chang ing Engine Oil Hot oil may cause burns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thor oughly wash...

Page 28: ...24 Water Pump This page intentionally left blank Maintenance...

Page 29: ...well as it should 1 Flow is restricted due to debris build up 2 Insufficient submergence of the end of suction hose 3 Excessively worn impeller 2 4 Seal is damaged 3 Liquid will be leaking through th...

Page 30: ...32 Water Pump This page intentionally left blank Troubleshooting...

Page 31: ......

Page 32: ...ts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290 Hw...