Generac Power Systems 3500XL Owner'S Manual Download Page 2

Generac Portable Products 3,500 Watt Generator

2

EQUIPMENT

DESCRIPTION

This generator is an engine-driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads. This manual
contains information for a generator that operates 120
and/or 240 Volt, single phase, 60 Hz devices that require up
to 3,500 watts (3.5 kW) of power that pull up to
29.2 Amps at 120 Volts or 14.6 Amps at 240 Volts.

CAUTION!

Do Not exceed the generator’s

wattage/amperage capacity. Add up the rated watts
of all devices you are connecting to generator
receptacles at one time. This total should not be
greater than 3,500 watts. In most cases rated watts
of the electrical device can be found on the device
nameplate. If the device nameplate gives only volts
and amps, multiply volts times amps to obtain watts
(volts X amps = watts).

The 3,500 watt generator has the following features:

• 120/240 Volt, 20 Amp locking type receptacle and a

120 Volt, 30 Amp locking type receptacle.

• 120 Volt, 15 Amp receptacles.

• Low Oil Shutdown: Automatically shuts down the engine

if oil drops below safe operation level.

• Four gallon overhead fuel tank with fuel gauge.

• The generator’s revolving field is driven at about

3,600 rpm by a Generac Power Systems 6.5 h.p. engine.

WARNING!

Do Not tamper with engine

governed speed. High operating speeds are
dangerous and increase risk of personal injury or
damage to equipment. The generator supplies
correct rated frequency and voltage only when
running at proper governed speed. Incorrect
frequency and/or voltage can damage some
connected electrical loads. Operating at excessively
low speeds imposes a heavy load. When adequate
engine power is not available engine life may be
shortened.

SAFETY RULES

This generator set was designed and manufactured for
specific applications. Do Not attempt to modify the unit
or use it for any application it was not designed for. If you
have any questions about your generator’s application, ask
your dealer/distributor or consult the factory.

The manufacturer could not possibly anticipate every
circumstance that might involve a hazard. For that reason
warnings in the manual and warnings on tags or decals
affixed to the unit are not all–inclusive. If you intend to
handle, operate or service the unit by a procedure or
method not specifically recommended by the manufacturer,
first make sure that such a procedure or method will not
render this equipment unsafe or pose a threat to you and
others.

Read this manual carefully and become familiar
with your generator set. Know its applications, its
limitations and any hazards involved.

DANGER!

You must isolate the generator from

the electric utility by opening the electrical system’s
main circuit breaker or main switch if this unit is
used for backup power. Failure to isolate the
generator from the power utility may result
in injury or death to electric utility workers
and damage to the generator 
due to a backfeed
of electrical energy. Whenever unit is providing
backup power, the electric utility must be notified.

DANGER

! Generator exhaust gases contain

DEADLY carbon monoxide gas. Carbon
monoxide, if breathed in sufficient
concentrations, can cause unconsciousness or
death. 
Operate this equipment outdoors where
adequate ventilation is available.

The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency. For warranty information refer to the
engine owner’s manual.

The engine exhaust from this product contains

chemicals known to the State of California to

cause cancer, birth defects, or other

reproductive harm.

WARNING:

Summary of Contents for 3500XL

Page 1: ...blems Questions Before taking your unit back to the store call the generator helpline at 1 800 270 1408 M F 8 5 CT 3500XL This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Portable Generator Owner s Manual ...

Page 2: ...e power is not available engine life may be shortened SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have any questions about your generator s application ask your dealer distributor or consult the factory The manufacturer could not possibly anticipate every circu...

Page 3: ...arance on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loads before shutting down the generator Do Not insert any object through cooling slots...

Page 4: ...e push to reset type Fuel Shut Off Valve Controls fuel supply to engine Fuel Tank Capacity of 4 U S gallons Grounding Wing Nut Provides a tie point for connecting the generator frame to earth ground Idle Control Switch The idle control runs the engine at normal high speeds when there is a load present and runs the engine at idle low speeds when a load is not present This feature greatly improves f...

Page 5: ... overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the Generator engine Do Not use premium gasoline Do Not mix oil with gasoline Clean area around fuel fill cap remove cap Add unleaded regular gasoline slowly to fuel tank Be careful not to overfill Allow about 1 2 of tank space for fuel expansion Figure 2 Install fuel cap and wipe up any spilled gasolin...

Page 6: ...Shutdown System See engine manual Refer to the engine owner s manual for complete starting instructions Grasp starter grip and pull slowly until you feel slight resistance then pull quickly Ease the starter rope back into the engine When engine starts move choke lever to Run position by sliding it all the way to the right away from the valve cover and under the arrow NOTE If engine fails to start ...

Page 7: ...tery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns If spill occurs flush area with clear water immediately Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery Do Not use the unit to charge any 6 Volt...

Page 8: ...40 F 4 C For a more permanent shelter build a structure that will enclose three sides and the top of the generator Make sure entire muffler side of generator is exposed A typical shelter is shown in Figure 6 Ensure a minimum of two feet clearance between open side of box and nearest object Face exposed end away from wind and elements Enclosure should hold enough heat created by the generator to pr...

Page 9: ...ocking Receptacle Use a NEMA L5 30 plug with this receptacle Connect a 3 wire cord set rated for 125 Volts AC at 30 Amps to the plug Figure 9 Use this receptacle to operate 120 Volt AC 60 Hz single phase loads requiring up to 3 500 watts 3 5 kW of power at 29 2 Amps The outlet is protected by a push to reset circuit breaker CAUTION Although this outlet states it has a 120 Volt 30 Amp rating up to ...

Page 10: ...ttage when selecting electrical devices to connect to your generator First figure the watts needed to start the largest motor Add to that figure the running watts of all other connected loads Items in the wattage reference guide Figure 10 are provided to help you to determine how many items the generator can operate at one time Recreational Home Uses Tool Appliance Watts AM FM clock radio 50 Light...

Page 11: ... the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp cloth to wipe exterior surfaces clean Soft bristle brush may be used to loosen caked on dirt or oil A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 ps...

Page 12: ...er in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to Run 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain gas tank and fill with fresh fuel 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank fill with fresh fuel 8 Put choke lever to no choke position 9 Fill crankcase ...

Page 13: ...Generac Portable Products 3 500 Watt Generator 13 NOTES ...

Page 14: ...Generac Portable Products 3 500 Watt Generator 14 SCHEMATIC DIAGRAM ...

Page 15: ...Generac Portable Products 3 500 Watt Generator 15 WIRING DIAGRAM ...

Page 16: ...Generac Portable Products 3 500 Watt Generator 16 EXPLODED VIEW MAIN UNIT ...

Page 17: ... 33 65795 1 RECTIFIER Battery Charge 34 66849A 1 M5 0 8 x 20 Taptite 35 67022 1 GROMMET Rubber 36 84132 1 MODULE Drive 37 66386 1 ASSEMBLY Brush Holder Item Part Qty Description 38 66849 2 TAPTITE M5 0 8 x 16 39 B4871 1 COVER Bearing Carrier 41 86494 1 SCREW M6 1 0 x 16mm Wing 42 86292 1 SCREW 10 16 x 3 4 Self Drill 43 77395 4 NUT M6 Flange Lock 44 83465 4 GROMMET Tank 46 78831B 4 SCREW M6 1 0 x 6...

Page 18: ... 2 CIRCUIT BREAKER 18 Amp 9 82538 1 SWITCH On Off Rocker 10 84134 1 GROMMET Rubber 11 83514 1 CIRCUIT BREAKER 10 Amp 12 83970 1 CONTROL BOARD System Item Part Qty Description 13 84028 1 TRANSFORMER Idle Control 14 67022 1 GROMMET Rubber 15 85584 1 BAR Bus 16 84543A 2 SCREW 3 0 x 12mm 17 84543C 9 SCREW 3 5 x 18mm 18 84198 3 SHIELD Circuit Breaker 19 84197 1 BAR Circuit Breaker Retaining 21 75476 2 ...

Page 19: ...Generac Portable Products 3 500 Watt Generator 19 NOTES ...

Page 20: ...ch have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices the generator need periodic parts service and replacement to perform well This warranty will not cover ...