Prestart Checklist
Before starting the unit, all items in the prestart checklist
must be completed. This checklist applies to both manual
and remote starting of the unit.
Verify all maintenance procedures are up to date. For
more information, refer to
General Maintenance
and
Basic Maintenance Schedule
.
Perform a walk-around inspection. Refer to
Daily
Walk-Around Inspection
.
The unit must be level.
The unit must be dry. Inspect for water inside or near
the unit; dry if needed.
For grounding requirements, follow the National
Electrical Code (NEC), state, and local regulations.
Verify the control power switch is OFF (O).
Verify all circuit breakers are OFF (O).
Inspect all electrical cords; repair or replace any that
are cut, worn, or bare.
Verify all winch cables are in good condition and
centered on each pulley. Do not use if cables are
kinked or beginning to unravel.
Check oil, coolant, and fuel levels. For more
information, refer to
General Maintenance
.
Verify battery connections are secure.
Turn the battery disconnect switch on, if equipped.
Inspect the engine fan belt tension and condition.
Inspect the engine fan belt guard.
Inspect the engine exhaust system for loose or
rusted components.
Verify all covers are in place and secure.
Starting the Unit (Key Switch
Models)
NOTE:
If the engine was run out of fuel or the fuel tank
was drained, it may be necessary to purge the fuel lines.
Refer to the engine operator’s manual supplied with the
unit.
1.
See
Figure 3-6
. Verify the main circuit breaker and
individual circuit breakers for each of the lights are
OFF (O).
Figure 3-6. Circuit Breakers in OFF (O) Position
2.
See
Figure 3-7
. Turn the key on the Engine Start
switch to the right GLOW PLUG position and hold
the key in place for five seconds.
Figure 3-7. Activate Glow Plug
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
CAUTION
(000230)
Equipment Damage. Do not continuously crank
engine for more than ten seconds. Doing so will lead
to overdischarge of batteries and starter seizure.
I
O
I
O
I
O
I
O
MAIN
BREAKER
240V
I
O
004386a
Summary of Contents for 3002908801
Page 42: ...Operation 38 Owner s Manual for MLT6SM 6SK Light Tower This page intentionally left blank ...
Page 48: ...Maintenance 44 Owner s Manual for MLT6SM 6SK Light Tower This page intentionally left blank ...
Page 65: ...Service Log Owner s Manual for MLT6SM 6SK Light Tower 61 This page intentionally left blank ...
Page 66: ...Service Log 62 Owner s Manual for MLT6SM 6SK Light Tower This page intentionally left blank ...
Page 67: ......