Remove all packaging material.

• 

Remove separate accessory box.

• 

Remove the generator from carton.

• 

Check all contents. If any parts are missing or damaged, locate an 
authorized dealer at 1-888-436-3722.

1 - Owner’s manual

• 

1 - Oil SAE 30

• 

3 - Product Registration Cards (English, Spanish, French)

• 

2 - 8” WHEELS

• 

1 - Axle

• 

1 - Frame Foot

• 

1 - Handle with grip

• 

1 - Hardware Bag

• 

1 - Plastic Spacer 

2 - M8-1.25 x 40 Bolts

1 - Handle Bracket 

1 - M6-1.0 x 40 Bolt

2 - Rubber Bumpers 

2 - M8-1.25 x 16 Bolts

2 - Cotter Pins 

1 - M6-1.0 Hex Flange Nut

2 - M8-1.25 Hex Flange Nuts

The generator requires some assembly prior to using it. If problems 
arise when assembling the generator, please call the Generator 
Helpline at 1-888-436-3722.

The wheels are designed to the unit to greatly improve the 
portability of the generator.

NOTICE:

The wheels are not intended for over-the-road-use.

1.  Refer to Figure 1 to install the wheels as shown.

• Slide the axle through the frame brackets.
• Slide on the wheels then install the cotter pins.

2.  Refer to Figure 1 to install the wheel bumpers as shown.

• Secure the two rubber bumpers to the frame foot 

using two M8-1.25 Hex Flange Nuts (if not already 
assembled).

• Place the frame foot under the frame and secure with two 

M8-1.25 x 16 bolts.

3.  Refer to Figure 2 to install the handle assembly as shown.

• Install the handle bracket to the frame using two M8-1.25 

x 40 bolts (if not already assembled).

• Slide the plastic spacer onto the handle assembly then 

align with the holes in the handle bracket (if not already 
assembled).

• Secure the handle assembly to the handle bracket using 

the M6-1.0 x 40 bolt and one M6-1.0 hex flange nut.

Figure 1 

–

 Wheel Assembly

Figure 2 

–

 Handle Kit

M8-1.25 x 40
BOLTS

1 X M6-10 HEX FLANGE NUT

1x HANDLE W/GRIP

1x PLASTIC SPACER

1x M6-1.0X40 BOLT

1x HANDLE BRACKET

Read the Owner’s Manual and Safety Rules before operating 
this generator.

Compare the generator to Figures 3 through 6 to become 
familiarized with the locations of various controls and adjustments. 
Save this manual for future reference.

1.  120 Volt AC, 20 Amp, Duplex Receptacle

 – Supplies electrical 

power for the operation of 120 Volt AC, 20 Amp, single-phase, 

60 Hz electrical lighting, appliance, tool and motor loads.

2.  120/240V AC, 20 Amp Locking Receptacle 

– Supplies 

electrical power for the operation of 120 and/or 240 volt AC, 

20 amp, single-phase, 60 Hz, electrical lighting, appliance, 

tool and motor loads.

3.  Circuit Breakers (AC)

 – Each receptacle is provided with a 

2-pole, 14 amp circuit breaker to protect the generator against 

electrical overload.

4. Air Filter

 – Filters intake air as it is drawn into the engine.

5. Choke Knob

 – Used when starting a cold engine.

6. Fuel Tank

 – Tank holds 4 U.S. gallons of fuel.

7. Grounding Lug

 – Ground the generator to an approved earth 

ground here. See "Grounding the Generator" for details.

8. On/OFF Switch

 – Controls the operation of the generator.

General Information

Summary of Contents for 005982-0

Page 1: ...Owner s Manual GP 3250 Portable Generator MODEL 005982 0...

Page 2: ...referencia de potencias 27 2 6 Antes de poner en marcha el generador 28 2 7 Arranque del motor 29 2 8 Detener del motor 29 2 9 Sistema de apagado nivel de aceite 29 Mantenimiento 29 3 1 Programa de ma...

Page 3: ...arefully Their definitions are as follows INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not a...

Page 4: ...hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connected to an ap...

Page 5: ...ING HANDBOOK available from the Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS available from the Americ...

Page 6: ...wo M8 1 25 x 40 bolts if not already assembled Slide the plastic spacer onto the handle assembly then align with the holes in the handle bracket if not already assembled Secure the handle assembly to...

Page 7: ...l level in tank 13 Oil Check Fill Check and fill oil here 14 Recoil Starter Use to start engine manually 15 Fuel Shut Off Valve between fuel tank and carburetor 16 Oil Drain Plug Used to drain engine...

Page 8: ...e exhaust fumes contain carbon monoxide which can you cannot see or smell This poisonous gas if breathed in sufficient concentrations can cause unconsciousness or even death Adequate unobstructed flow...

Page 9: ...ctrical devices to connect to the generator 1 Figure the watts needed to start the largest motor 2 Add to that figure the running watts of all other connected loads The Wattage Reference Guide is prov...

Page 10: ...ng the fuel tank Do not overfill the fuel tank Always leave room for fuel expansion If the fuel tank is overfilled fuel can overflow onto a HOT engine and cause FIRE or EXPLOSION Use regular UNLEADED...

Page 11: ...ce is required when operating in adverse conditions noted below Check Oil Level At Each Use Change Oil Every 50 Hours Check Valve Clearance Every Season Service Air Filter Every 25 Hours Replace Spark...

Page 12: ...ter and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Use a damp cloth to wipe exterior surfaces clean A soft bristle brush may b...

Page 13: ...park Arrestor The engine will not run properly and may be damaged if using a dirty air filter Clean the air filter every 25 hours Figure 15 Clean or replace more often if operating under dusty conditi...

Page 14: ...the cylinder Cover spark plug hole with rag Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore Avoid spray from spark plug hole when cranking engine Install and ti...

Page 15: ...Low oil level 9 Excessive rich fuel mixture 10 Intake valve stuck open or closed 11 Engine has lost compression 1 Clean or replace air filter 2 Fill fuel tank 3 Drain fuel tank and fill with fresh fue...

Page 16: ...14 Notes...

Page 17: ...15 Notes...

Page 18: ...ntacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged...

Page 19: ...hat part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired or replac...

Page 20: ...le generators built prior to June 2010 Generac portable generators that utilize non Generac replacement parts Costs of normal maintenance and adjustments Failures caused by any contaminated fuels oils...

Reviews: