Generac Portable Products 9719-3 Owner'S Manual Download Page 11

Generac Portable Products SVP5000 Generator

11

TROUBLESHOOTING

Problem

Cause

Solution

Engine is running, but

no AC output is

available.

1.  Circuit breaker is open.

2.  Poor connection or defective cord

set.

3.  Connected device is bad.

4.  Fault in generator.

1.  Reset circuit breaker.

2.  Check and repair.

3.  Connect another device that is in good

condition.

4.  Contact Generac service facility.

Engine runs good but

bogs down when loads

are connected.

1.  Short circuit in a connected load.

2.  Generator is overloaded.

3.  Engine speed is too slow.

4.  Shorted generator circuit.

1.  Disconnect shorted electrical load.

2.  See “Don’t Overload the Generator” on

page 9.

3.  Contact Briggs & Stratton service

facility.

4.  Contact Generac service facility.

Engine will not start; or

starts and runs rough.

1.  On/Off switch set to 

Off

 (o).

2.  Dirty air cleaner.

3.  Out of gasoline.

4.  Stale gasoline.

5.  Spark plug wire not connected to

spark plug.

6.  Bad spark plug.

7.  Water in gasoline.

8.  Overchoking.

9.  Low oil level.

10.  Excessively rich fuel mixture.

11.  Intake valve stuck open or closed.

12.  Engine has lost compression.

1.  Set switch to 

On

 (–).

2.  Clean or replace air cleaner.

3.  Fill fuel tank.

4.  Drain gas tank and fill with fresh fuel.

5.  Connect wire to spark plug.

6.  Replace spark plug.

7.  Drain gas tank; fill with fresh fuel.

8.  Put choke lever to 

“Run”

 position.

9.  Fill crankcase to proper level.

10.  Contact Briggs & Stratton service

facility.

11.  Contact Briggs & Stratton service

facility.

12.  Contact Briggs & Stratton service

facility.

Engine shuts down

during operation.

1.  Out of gasoline.

2.  Low oil level.

3.  Fault in engine.

1.  Fill fuel tank.

2.  Fill crankcase to proper level.

3.  Contact Briggs & Stratton service

facility.

Engine lacks power.

1.  Load is too high.

2.  Dirty air filter.

3.  Engine needs to be serviced.

1.  See “Don’t Overload the Generator” on

page 9.

2.  Replace air filter.

3.  Contact Briggs & Stratton service

facility.

Engine “hunts” or

falters.

1.  Choke is opened too soon.

2.  Carburetor is running too rich or

too lean.

1.  Move choke to halfway position until

engine runs smoothly.

2.  Contact Briggs & Stratton service

facility.

Summary of Contents for 9719-3

Page 1: ...the danger Always have at least two feet of clearance on all sides of the generator even while operating the unit outdoors DANGER You must isolate the generator from the electric utility by opening t...

Page 2: ...eds when adequate engine power is not available and may shorten engine life SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or...

Page 3: ...eather Operation on page 7 Never start or stop the engine generator with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before con...

Page 4: ...C Each receptacle is provided with a circuit breaker to protect the generator against electrical overload Breakers are push to reset type Fuel Shut Off Controls fuel supply to engine Fuel Tank Capacit...

Page 5: ...erfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the Generator engine Do Not use premium gasoline Do Not mix oil with gasoline Clean area around fuel fill c...

Page 6: ...n engine starts move choke lever to Run position NOTE If engine fails to start after 3 pulls move the choke lever to Run and pull starter rope again NOTE If the engine still fails to start check for p...

Page 7: ...e box to expose exhaust side of unit Ensure a minimum of two feet clearance between open side of box and nearest object Cut appropriate slots to access receptacles of unit You may also need to cut a c...

Page 8: ...igure 8 You can use the same 4 wire cord if you plan only to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads and is protected by a 20 Amp push to reset circuit brea...

Page 9: ...when selecting electrical devices to connect to your generator First figure the watts needed to start the largest motor Add to that figure the running watts of all other connected loads Devices in the...

Page 10: ...e rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp c...

Page 11: ...n gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Clean or replace air cleaner 3 Fill f...

Page 12: ...Generac Portable Products SVP5000 Generator 12 ELECTRICAL SCHEMATIC...

Page 13: ...Generac Portable Products SVP5000 Generator 13 WIRING DIAGRAM...

Page 14: ...Generac Portable Products SVP5000 Generator 14 EXPLODED VIEW GENERATOR...

Page 15: ...831B 4 CAPSC M6 x 60 mm Hx Hd 31 90878 1 CAP Fuel 32 77395 4 NUT M6 Flange Lock 33 78299 1 BUSHING Plastic Tank 34 80270 1 VALVE Plastic Tank 35 81898 1 PANEL Control Item Part Qty Description 36 8191...

Page 16: ...ng overspeeding improper maintenance repair or storage so as in the COMPANY s judgment to adversely affect its performance and reliability THERE IS NO OTHER EXPRESS WARRANTY THE COMPANY HEREBY DISCLAI...

Reviews: