5500 Watt Heavy  Duty Generator

NOTES

Summary of Contents for 1654-0

Page 1: ...amiento 7 9 25 27 Product Specifications Especificaciones Del Producto 10 28 Maintenance Mantenimiento 10 28 Storage Almacenamiento 11 29 Troubleshooting Diagnosticos De Averías 12 30 Schematic Esquemático 14 Wiring Diagram Digrama Eléctrico 15 Replacement Parts Piezas De Recambio 16 19 Notes Notas 13 Garantia 31 Warranty Last Page Generator Generador Wheel Kit Juego de Llantas Locking 30 Amp Plug...

Page 2: ...ion refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have any questions about your generator s application ask your dealer or consult the factory The manufacturer could not possibly anticipate every circumstance that might involve ...

Page 3: ...n all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loads before shutting down the generator Do Not insert any object through cooling slots of the ...

Page 4: ...TENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30 Amp plug Engine oil Wheel kit INSTALL WHEEL KIT The wheel kit is designed to greatly improve the portability of your generator NOTE Wheel kit is not intended for over the road use You will need a socket wrench with 1 2 or 13mm sock...

Page 5: ...tor on a level surface Follow the oil grade recommendations and oil fill instructions given in the engine owner s manual NOTE The generator s revolving field rides on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Allow unit to cool for t...

Page 6: ...ical overload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 3 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch off engine Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester screen KNOW...

Page 7: ... a low oil shutdown device which prevents the engine from being started and shuts the engine down when the oil drops below a safe level in the crankcase See engine manual Refer to the engine owner s manual for more detailed starting instructions Connecting Electrical Loads Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 and or 240 Volt AC singl...

Page 8: ... that exceed the wattage amperage capacity of the generator can damage it or cause serious injuries 120 Volt AC 20 Amp Duplex Receptacles Each duplex receptacle Figure 8 is protected against overload by a push to reset circuit breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated ...

Page 9: ...erator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or appli...

Page 10: ...in cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any ...

Page 11: ...n the Generator Check that cooling air slots and openings on generator are open and unobstructed CAUTION Storage covers can be flammable Do Not place a storage cover over a hot generator Let the unit cool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips Do Not store gasoline from one season to another Replace fu...

Page 12: ...asoline 6 Stale gasoline 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in gasoline 10 Overchoking 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression 1 Set switch to On 2 Turn fuel valve to the Open position 3 Fill crankcase to proper level 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain gas tank and fill with fresh ...

Page 13: ...13 5500 Watt Heavy Duty Generator NOTES ...

Page 14: ...5500 Watt Heavy Duty Generator 14 SCHEMATIC ...

Page 15: ...15 5500 Watt Heavy Duty Generator WIRING DIAGRAM ...

Page 16: ...5500 Watt Heavy Duty Generator 16 EXPLODED VIEW MAIN UNIT ...

Page 17: ...S 1 DECAL Hot Muffler 32 91825GS 1 ASSEMBLY Brush Holder 33 66849GS 2 TAPTITE M5 0 8 x 16 34 B4871GS 1 COVER Bearing Carrier 35 23762GS 2 WASHER 10 Ext Shakeproof Item Part Qty Description 36 86494GS 1 SCREW M6 1 0 x 16 Wing 37 B2153GS 2 SCREW 10 Self Drilling 38 56893GS 5 SCREW 10 24 x 1 2 Crimptite 39 189948GS 2 DECAL Heat Shield 40 77395GS 4 NUT M6 Flange Lock 41 80270GS 1 VALVE Tank 42 78299GS...

Page 18: ...andle 2 B187101GS 1 LEG Mounting 3 52858GS 5 NUT Locking Hex M8 1 25 4 39287GS 2 HHCS M8 1 25 x 45 5 93693GGS 1 AXLE 6 B4966GS 2 WHEEL 10 Diameter 7 87005AGS 2 PIN Retaining 8 22247GS 2 WASHER Flat 5 8 9 39253GS 1 HHCS M8 1 25 x 20 10 42909GS 2 HHCS M8 1 25 x 30 11 22145GS 2 WASHER Flat 5 16 M8 12 27007GS 2 MOUNT Vibration ...

Page 19: ...nge Pin 5 189166GS 2 PIN Hinge Cover Compact 6 68759GS 2 OUTLET 120V 20Amp Duplex 7 189165GS 4 NUT Palnut Pushnut 5 32 8 84198GS 2 CAP Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 OUTLET 120 240 Locking 30A 11 189164GS 2 NUT Palnut Pushnut 3 16 12 84543CGS 2 SCREW Phillips Head 3 5 x 18 13 93857GS 1 BAR Retaining 14 188890GS 1 COVER Back Control Panel 15 82308GS 6 SCREW Self Tapping ST...

Page 20: ... mayor información acerca de la garantía consulte con el manual del propietario del motor INSTRUCCIONES DE SEGURIDAD Este generador fue diseñado y fabricado para usos específicos No intente modificar la unidad o usarla para otro uso para el cual no fue diseñado Si usted tiene alguna pregunta acerca del uso del generador pregúntele a su vendedor o consulte con el fabricante No es posible que el fab...

Page 21: ...ador incluso cuando la unidad esté funcionando en exteriores de otra forma podría dañar la unidad Nunca arranque o detenga el motor generador cuando tenga cargas eléctricas conectadas a los tomacorrientes y los dispositivos conectados estén ENCENDIDOS Arranque el motor y permita que se estabilice antes de conectar las cargas eléctricas Desconecte todas las cargas eléctricas antes de apagar el gene...

Page 22: ...no etc Saque el generador de la caja de envío CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no está presente o está dañada por favor llame a la linea de ayuda para generadores al 1 800 270 1408 La unidad principal Manual del propietario Aceite para motor Tapones de fijación Juego de llantas INSTALE EL JUEGO DE RUEDAS El juego de ruedas está diseñado para mejorar el transpor...

Page 23: ...otor Coloque la generador sobre una superficie nivelada Consulte el manual del propietario del motor para añadir al motor el aceite recomendado NOTA El campo giratorio del generador se encuentra en un cojinete pre lubricado y sellado que no requiere lubricación adicional por la vida útil del cojinete Agregue Gasolina ADVERTENCIA Nunca llene el tanque del combustible en recintos cerrados Nunca llen...

Page 24: ...pagachispas Tanque del Combustible El tanque tiene una capacidad de 7 galones americanos de gasolina sin contenido de plomo Terraplén del aceite Agregue el aceite de motor aquí Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentación eléctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminación eléctrica de 120 Voltios ...

Page 25: ...aceite en el cigüeñal Esta unidad está equipada con un Sistema que se apaga cuando el aceite esté bajo Consulte con el manual del motor Consulte con el manual del propietario del motor para las instrucciones completas de encendido Conexion De Cargas Electricas Deje que el motor se estabilice y se caliente por unos minutos después del arranque Conecte y encienda las cargas eléctricas de 120 y o 240...

Page 26: ... que pasen la capacidad de amperaje y vataje del generador pueden dañarlo o causar accidentes muy serios 120 Volt AC 20 Amp Receptáculos Dobles Cada receptáculo Figura 17 está protegido en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Use cada receptáculo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corr...

Page 27: ...el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la próxima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga Nunca añada más cargas sobre la capacidad del generador Tome una atención especial en considerar las cargas de corriente según la capacidad del generador como se describe arriba El vataje que a...

Page 28: ...otor y causar problemas Además si el agua se introduce al generador a través de las ranuras para aire de enfriamiento algo del agua quedará retenida en los espacios vacíos y grietas del aislamiento del devanado del estator y rotor La acumulación de agua y suciedad en los devanados internos del generador disminuirá eventualmente la resistencia del aislamiento de estos devanados Para Limpiar el Gene...

Page 29: ...29 5500 Watt Pesado Generador NOTAS ...

Page 30: ... gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La válvula de corte de combustible 12 La válvula de entrada está atascada está cerrada 13 El motor ha perdido compresión 1 Coloque del interruptor en On 2 Gire la válvula del combustible a la posición On 3 Limpie o reemplace el depurador de aire 4 Llénelo con combustible fresco 5 Drene el tanque de gasolina llénelo con combusti...

Page 31: ...locidad mantenimiento inadecuado reparación o almacenamiento que según el punto de vista de la COMPAÑÍA afecte de una manera negativa su rendimiento y fiabilidad NO EXISTE OTRA GARANTÍA EXPRESA LA COMPAÑÍA POR LO TANTO NIEGA CUALQUIER O TODAS LAS GARANTÍAS IMPLICADAS INCLUYENDO PERO NO LIMITADAS A AQUELLAS DE MERCADEO Y ESTADO FÍSICO PARA UN PROPÓSITO EN PARTICULAR A LA EXTENSIÓN DE LA LEY LA DURA...

Page 32: ...ormal maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices the generato...