![Generac Portable Products 1417-1 Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/generac-portable-products/1417-1/1417-1_owners-manual_2208869012.webp)
Generac Portable Products 2,500 PSI High Pressure Washer
12
12
2.
If the screen is damaged, the o-ring kit contains a
replacement in-line filter screen and an o-ring. If
undamaged, reuse screen.
3.
Place the in-line filter screen into the threaded end of
the nozzle extension. Direction does not matter. Push
the screen in with the eraser end of a pencil until it
rests flat at the bottom of the opening. Take care to
not bend the screen.
4.
Place the o-ring into the recess. Push the o-ring snugly
against the in-line filter screen.
5.
Assemble the nozzle extension to the spray gun, as
described earlier in this manual.
Check Chemical Injection Tube
Examine the filter on the detergent hose and clean if
clogged. The tube should fit tightly on the barbed fitting.
Examine the tube for leaks or tears. Replace the filter or
tube if either is damaged.
Purge Pump of Air and
Contaminants
To remove the air from the pump, follow these
steps:
• Set up the pressure washer as described in “How To Use
Your Pressure Washer” on page 8.
• Connect the water supply and turn water on.
• Remove the nozzle extension from the gun.
• Pull the trigger on the gun and hold.
To remove the contaminants from the pump, follow
these steps:
• Set up the pressure washer as described in “How To Use
Your Pressure Washer” on page 8.
• Connect the water supply and turn water on.
• Remove the nozzle extension from the gun.
• Start the engine according to instructions in “How To
Use Your Pressure Washer” on page 8.
• Squeeze the trigger on the gun and hold.
• When the water supply is steady and constant, engage
the safety latch and refasten the nozzle extension.
Cleaning Chemical Injection Tube
If you have used the chemical injection tube you must flush
it with clean water before stopping the engine.
• Place the chemical injection tube in a bucket full of clean
water.
• Flush for 1–2 minutes.
• Shut off the engine.
IMPORTANT: Simply shutting OFF engine will not
release pressure in the system. When the engine has
stopped, squeeze the trigger on the gun to relieve the
pressure in the hose.
Nozzle Maintenance
If a nozzle becomes restricted or clogged with dirt or
foreign materials, a pulsing sensation caused by excessive
pump pressure may occur during use.
Immediately clean a clogged or partially restricted nozzle
with the kit included with your pressure washer by
following these instructions:
• Shut off the engine and turn off the water supply.
• Disengage the safety latch and pull the trigger on the
spray gun. Hold until all water is purged from the unit.
Engage the safety latch on the spray gun.
• Separate the nozzle extension from the spray gun.
• Twist nozzle to stream setting.
• Remove nozzle from the end of the nozzle extension
using a 2 mm or 5/64 allen wrench (included in Nozzle
Cleaning Kit).
• Use the wire included in the kit or a small paper clip to
free the foreign materials clogging or restricting the
nozzle (Figure 14).
Use wire here
to remove
debris.
Figure 14 — Nozzle Maintenance
Summary of Contents for 1417-1
Page 14: ...Generac Portable Products 2 500 PSI High Pressure Washer 14 14 NOTES ...
Page 15: ...Generac Portable Products 2 500 PSI High Pressure Washer 15 15 NOTES ...
Page 17: ...Generac Portable Products 2 500 PSI High Pressure Washer 17 17 NOTES ...
Page 18: ...Generac Portable Products 2 500 PSI High Pressure Washer 18 18 EXPLODED VIEW UNIT ...
Page 20: ...Generac Portable Products 2 500 PSI High Pressure Washer 20 20 EXPLODED VIEW PUMP 49 ...
Page 22: ...Generac Portable Products 2 500 PSI High Pressure Washer 22 22 EXPLODED VIEW UNLOADER 43 42 ...