![Generac Portable Products 1042-3 Owner'S Manual Download Page 14](http://html1.mh-extra.com/html/generac-portable-products/1042-3/1042-3_owners-manual_2208863014.webp)
Generac 2250PSI High Pressure Washer
GENER
A
C
The Reliable Ones
14
Cleaning Chemical Injection Tube
If you have used the chemical injection tube you must
flush it with clean water before stopping the engine.
Place the small filter end of the chemical injection
tube in a bucket of clean water.
Slide the adjustable nozzle forward.
Squeeze the spray gun trigger for two minutes to
flush the chemical injection tube.
Shut off the engine.
Important:
Simply shutting OFF engine will not release
pressure in the system. When engine has shut down,
squeeze the trigger on the gun to relieve the
pressure in the hose.
Nozzle Maintenance
If the adjustable nozzle becomes restricted or
clogged with foreign materials, such as dirt, excessive
pump pressure may develop. If this nozzle becomes
partially clogged, it can cause a pulsing sensation
during use. This generally is not a pump related
problem, but rather a clogged or partially restricted
adjustable nozzle.
If the adjustable nozzle becomes clogged or partially
restricted, immediately clean the nozzle with the kit
included with your pressure washer by following
these instructions:
Shut off the engine and turn off the water supply.
Separate the nozzle extension from the gun.
Adjust the nozzle extension to the stream position.
Remove nozzle from the end of the wand extension
(Figure 17) using a 2mm or 5/64 allen wrench (like
the one included in the kit).
Use the wire included in the kit (Figure 17) or a
small paper clip to free the foreign materials
clogging or restricting the nozzle.
Figure 17 — Removing and cleaning nozzle.
Remove additional debris by back flushing water
through wand extension (Figure 18). Back flush
between 30 to 60 seconds. Turn nozzle extension
to stream spray and move nozzle forward and
backward while flushing.
Figure 18 — Backflushing the nozzle.
Reinstall nozzle into the wand extension. DO NOT
overtighten.
Reconnect the nozzle extension to the spray gun.
Reconnect the water supply, turn on the water, and
start the engine.
Test the pressure washer by operating with nozzle
in the high and in the low position.
ENGINE MAINTENANCE
See the Engine Owners Manual for instructions on
how to properly maintain the engine.
SERVICE AND
ADJUSTMENTS
See the Engine Owners Manual for instructions on
how to properly service and adjust the engine.