![Generac Mobile MFH900 Owner'S Manual Download Page 18](http://html.mh-extra.com/html/generac-mobile/mfh900/mfh900_owners-manual_2208805018.webp)
14
Owner’s Manual for Flameless Air Heater
General Information
Emissions Information
For emissions information, see the OEM engine manual.
Engine Oil Recommendations
Genuine Generac parts are recommended for all
maintenance items.
All Generac oil kits meet minimum American Petroleum
Institute (API) Service Class CJ-4/SM. Select the
appropriate viscosity oil grade according to the expected
operating temperature. Synthetic oil also can be used in
the appropriate weight as standard, once the engine has
been broken in. Once synthetic oil is used, it should be
used for the life of the unit. It is not recommended to go
back to a mineral oil. Do not use special additives.
See
for engine oil capacity.
Figure 2-11. MFH900 Engine Oil Viscosity
NOTE:
For temperatures below -4 °F (-20 °C), use SAE
5W-30.
For more information, see the engine manual.
Coolant Recommendation
Where the atmospheric temperature falls below freezing,
the cooling system should be drained after engine
operation. To eliminate the need for repeated draining
and refilling, the use of a 50/50 Ethylene glycol base
antifreeze/water mix is recommended. Never exceed a
60/40 antifreeze/water mix.
NOTE:
Recommended coolant is ZEREX™ Nitrate Free
Extended Life Antifreeze/Coolant.
See
for coolant capacity.
For more information, see the engine manual.
Fuel System
The heater is designed to operate with diesel fuel.
See
for fuel tank capacity.
IMPORTANT NOTE: Comply with all laws regulating
the storage and handling of fuels.
Follow these guidelines:
•
Use only ultra-low-sulfur diesel fuel.
•
When temperatures are at or below freezing, use
No. 1D diesel fuel.
•
When temperatures are above freezing, use No.
2D diesel fuel.
•
In some areas of the country, climatized fuel—a
mixture of 1D and 2D, may also be used.
000000
(000149)
DANGER
Risk of poisoning. Do not use mouth to siphon
coolant. Doing so will result in death or serious
injury.
Freezing Point °F (°C)
3
(-16)
-13
(-25)
-31
(-35)
-58
(-50)
Coolant (% Volume)
30
40
50
60
Water (% Volume)
70
60
50
40
(000168)
DANGER
Explosion and Fire. Fuel and vapors are
extremely flammable and explosive. Keep fire
and spark away. Failure to do so will result
in death or serious injury.
(000204)
DANGER
Explosion and Fire. Do not overfill fuel tank.
Overfilling may cause fuel to leak and ignite
or explode, resulting in death or serious injury.
Summary of Contents for MFH900
Page 4: ...iv Owner s Manual for Flameless Air Heater This page intentionally left blank ...
Page 28: ...24 Owner s Manual for Flameless Air Heater Operation This page intentionally left blank ...
Page 40: ...36 Owner s Manual for Flameless Air Heater Troubleshooting This page intentionally left blank ...
Page 41: ...Owner s Manual for Flameless Air Heater 37 Section 6 Wiring Diagrams Main Control System ...
Page 46: ...42 Owner s Manual for Flameless Air Heater Wiring Diagrams ...
Page 48: ...44 Owner s Manual for Flameless Air Heater Wiring Diagrams This page intentionally left blank ...
Page 49: ...Owner s Manual for Flameless Air Heater 45 Wiring Diagrams This page intentionally left blank ...
Page 50: ...46 Owner s Manual for Flameless Air Heater Wiring Diagrams This page intentionally left blank ...
Page 51: ......