21
/
26
4.
Panel Settings
4.1.
Power on or off
Short press the power button to start the machine, long press the power button to shut it
down. After receiver is started, the default setting will be the working mode setting of the last
shutdown, and the setting interface in relevant mode
4.2.
Working Status Interface
【
Working Mode
】
Here you can set “Base station”, “Rover Station”, “Static”. After entering
the main interface, you can right-click to enter the main setting interface
4.2.1.
Base Station Mode Interface
Click "Work Mode" → click "Base" to enter the base station set
ting interface, including whether to start
automatically, limit PDOP, base station ID→ Click "Ok" after setting. If automatic recording is selected,
click "Ok" to start recording automatically; If you do not select automatic recording, you need to manually
click "Start Recording" to start recording.
4.2.2.
Rover Station Mode Interface
Click "Working Mode" → click "
Rover" to finish "Rover Station settings"
4.2.3.
Static Mode Interface
Click "Working mode" → click "Static" to enter the static setting
interface, including sampling interval, cut-
off Angle and whether to automatically record Settings → click "Confirm" after setting. If automatic
recording is selected, click "Confirm" to start recording automatically; If you do not select automatic
recording, you need to manually click "Start Recording" to start recording.