background image

Genelec Document D0158R001c. Copyright Genelec Oy 10.2021. All data subject to change without prior notice.

www.genelec.com

International enquiries: 
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]

In the U.S. please contact: 
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]

In China please contact:
Beijing Genelec Audio Co.Ltd
B33 - 101 
Universal Business Park
No. 10 Jiuxianqiao Road
Chaoyang District 
100015 Beijing, China 
Phone +86 (10) 5823 2014, 400 700 1978
Email [email protected]

In Sweden please contact:
Genelec Sverige
Ellipsvägen 10B
P.O. Box 2306
S-127 02 Skärholmen
Phone +46 8 449 5220
Fax +46 8 708 7071
Email [email protected]

* The notch and shelving filters adjustments, AutoCal

TM

 and GLM

TM 

manual system calibration features are part of the Genelec Loudspeaker Manager (GLM

TM

) software

8361A

Analog signal input connector XLR female, balanced 10 kOhm

Maximum analog input signal 

Analog input sensitivity (100 dB SPL at 1 m) 

Analog input sensitivity control

pin 1 gnd 

pin 2 non-inverting  

pin 3 inverting

 

+25.0 dBu 

-6 dBu 

Adjustable from +36 to -6 dBu

Digital signal input connector XLR female 110 Ohm

Digital signal output / Thru connector XLR male 110 Ohm 

 

Digital audio input

Word length 

Sample rate

Digital input sensitivity (100 dB SPL at 1 m) 

Digital input maximum attenuation using DIP switches

Digital input maximum attenuation using GLM software

AES/EBU Single Wire

AES/EBU Single Wire 

 

16 - 24 bits

32 - 192 kHz 

-30 dBFS 

42 dB 

120 dB

Input to output delay at high frequencies, linear phase, analog input 

Input to output delay, analog input with ultra wide linear range

(When using the AES/EBU digital audio input, the system latency may differ slightly from 

the published value due to effects of the active sampling rate)

4.2 ms 

8.6 ms

Control network

Type

Connection

Proprietary GLM™ network

2 RJ45, CAT5 cables

Crossover frequencies

Bass/Mid

Mid/Treble

 

320 Hz

2800 Hz

GLM

TM

 software frequency response adjustment*

Parametric notch filters

Shelving filters

16

2 LF and 2 HF

System room response calibration

Genelec GLM AutoCal™, GLM

TM

 manual, Stand-alone*

SIGNAL PROCESSING

Bass amplifier short term output power

Midrange amplifier short term output power

Treble amplifier short term output power

(Long term output power is limited by driver protection circuitry)

700 W 

150 W 

150 W

Amplifier system THD at nominal output

<0.05%

Mains voltage

100-240 VAC 50/60 Hz

Power consumption

ISS active

Idle

Full output (short term)

< 1.5 W 

20 W 

600 W

AMPLIFIER SECTION

Summary of Contents for SAM 8361A

Page 1: ...8361A Smart Active Monitor Operating Manual ...

Page 2: ...re edges and sum acoustically placing bass on the same acoustical axis with the coaxial transducer This unique design enables directivity control of all audio down to low bass frequencies Smart Active Monitoring SAM Smart Active Monitors automatically tune several parametric filters in themselves to precisely compensate for room colorations using Genelec Loudspeaker Manager GLM software This enabl...

Page 3: ...he monitor These stand alone settings are limited and provide some fundamental compensations for room acoustic effects input selections and input sensitivity To use disconnect the GLM management network and set the DIP switch Stored to OFF position ANALOG IN DIGITAL THRU AES EBU DIGITAL IN AES EBU MADE IN FINLAND 8361A SERIAL NUMBER www genelec com GLM NETWORK MAINS INPUT 50 60 Hz 600 W 100 240 V ...

Page 4: ...nsates high frequency loss when a monitor is placed behind a screen LED Disable This switch turns off the front panel LED light ISS This switch activates and deactivates the ISS power saving function when the 8361 is used in a Stand Alone mode The default time for going to power save mode is 60 minutes but this can be adjusted in the GLM software Digital The Digital switch selects the digital audi...

Page 5: ...elec certified service Safety Considerations The 8361A follows international safety standards To ensure safe operation the following warnings and precautions must be observed Servicing and adjustment must only be performed by certified Genelec service personnel The monitor enclosure must not be opened Use the product only with a mains cable having a protective ground terminal and with a mains conn...

Page 6: ...0 45 70 75 80 85 90 95 dB SPL 80 85 90 95 dB SWL 20 20k 50 100 200 500 1k 2k 5k 10k Frequency Hz Genelec Oy 8361A dB vs freq Hz 30 Sept 2019 80 85 90 BASS ROLL OFF TREBLE TILT 80 85 90 80 85 90 DESKTOP LF BASS TILT dB SPL Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to whi...

Page 7: ...t in the same conditions with IEC weighted noise limited by driver protection circuit at 1 m 109 dB SPL Maximum peak acoustic output per pair in a listening room with music material at 1 m 128 dB SPL Self generated noise level in free space at 1 m on axis A weighted 5 dB Harmonic distortion at 95 dB SPL at 1 m on axis Freq 50 100 Hz 100 Hz 3 0 5 Drivers Bass Midrange Treble Dual 263 x 137 mm 103 8...

Page 8: ...al signal input connector XLR female 110 Ohm Digital signal output Thru connector XLR male 110 Ohm Digital audio input Word length Sample rate Digital input sensitivity 100 dB SPL at 1 m Digital input maximum attenuation using DIP switches Digital input maximum attenuation using GLM software AES EBU Single Wire AES EBU Single Wire 16 24 bits 32 192 kHz 30 dBFS 42 dB 120 dB Input to output delay at...

Reviews: