background image

Genelec 1234AC Operating Manual

Introduction

Congratulations and thank you for 
choosing Genelec!

Since 1978, Genelec has been guided 

by a single idea – to make perfect 
active monitors that deliver neutral and 
accurate sound in every kind of acoustical 
environment. In Genelec’s quest for this 
ultimate goal, our unrivalled commitment 
to research and development has led us 
to continuously develop innovative driver 
technology, electronic circuitry, enclosure 
designs and more. Our design philosophy is 
based on sustainability and environmental 
values, where industrial design serves our 
products' acoustical performance.

Your Genelec product has been designed 

and manufactured with care in our factory, 
in Finland, using environmentally efficient 
solutions to give you reliable operation 
over many years.

Please take the time to read this manual. 

Happy monitoring!

General Description

The Genelec 1234AC Smart Active Monitor 
is designed for neutral sound reproduction 
at high SPLs in large control rooms. The 
system comprises of a 160 litre enclosure 
and a RAM-XL 19 in 3U rack mount 
amplifier unit.

The monitor enclosure contains two 

305 mm (12 in) bass drivers, a 130 mm 
(5 in) midrange, and a 25 mm (1 in) treble 
driver. The midrange and treble drivers are 
mounted in a Genelec Directivity Control 
Waveguide™ (DCW™) which can be 
rotated through ±90° for either horizontal 
or vertical mounting. The system low 
frequency response extends down to 29 
Hz (-6 dB). The high frequency response 
extends up to 21 kHz (-6 dB). 

Digital signal processing in the RAM-XL 

amplifier unit is done with high precision 
algorithms, and includes driver and 
amplifier overload protection. The room 
response compensations include highly 
flexible parametric filters, level alignment, 
and acoustic delay compensation. These 
allow accurate matching to all console 
output sections and room acoustics. 

The power amplifiers of the RAM-XL 

produce 2 x 750 W, 400 W and 250 W of 
short term power in the bass, midrange, 
and treble channels respectively. 

Delivery Content

The Genelec 1234AC Smart Active Monitor 
is shipped in a box containing an enclosure, 
an individually calibrated RAM-XL amplifier 
unit, a mains connecting cable, an RJ45 
cable and one Allen key. 

Before installing the system, check 

all items for damage and omissions. If 
damage is found, contact directly the 
distributor and insurance agent. If there 
are any missing components, contact your 
local dealer.

Cables 

Each 1234AC is delivered with the following 
cable kit:

•  One mains cable
•  Two 10 m (32 ft 9 in) 4-pole Speakon 

cables

•  One 10 m (32 ft 9 in) RJ45 cable
•  One 5 m (16 ft 4 in) RJ 45 cable

The 10 m cables are designed to go 
between the amplifier and the monitor 
enclosure. If you need to make custom 
length cables for this, please connect the 
Speakon cables pin to pin and see Table 1 
for recommended wire gauges.

Amplifier Positioning

The RAM-XL amplifier is encased in a 
standard 19" 3U rack case. The cooling 
system circulates air into the amplifier 
from behind, so that it exits through the 
openings on the right side. Free flow of 
fresh air must be ensured and the space 
around the amplifier must be sufficiently 
ventilated to dissipate accumulating heat 
so that the temperature does not rise 
above 15-35 degrees Celsius (50-95°F). If 
the system overheats it will stop operating 
until a safe temperature is reached.

Make sure that the amplifier is positioned 

so that the monitor connecting cables will 
reach. A space 100 mm (4 in) deep should 
be left behind the rear panel of the amplifier 
unit to allow for the cable connectors and 
air circulation. 

The RAM-XL amplifier is compatible with 

mains voltage supply of 100 - 120 VAC and 
220 - 240 VAC 50/60 Hz.

Operating Environment 

These monitors and their RAM-XL 
amplifiers are designed for indoor use 
only. The permissible ambient temperature 
is 15-35 degrees Celsius (50-95°F) and 
permissible relative humidity between 
20% and 80%. Humidity condensation on 
the product is not allowed during use. For 
instance, if the product has been stored or 
transported in a cool environment and then 
taken into a warm room, it must be allowed 
to warm up to the ambient temperature 
before connecting to mains power. 

Aligning the DCW

The 1234AC monitor is designed to be flush 
mounted in either the vertical or horizontal 
configuration. The DCW should be rotated 
so that the treble and midrange drivers 
align vertically (see Figure 1). This ensures 
that optimum stereo symmetry is obtained.

IMPORTANT-The DCW plate is heavy, 

care must therefore be taken when 
removing and replacing the DCW. To rotate 
the DCW plate, proceed as follows:

•  Place the monitor in its intended 

listening orientation. 

•  Unscrew the eight M5 fixing screws on 

the edges of the plate using a 4 mm 
Allen key. 

•  Carefully pull the plate a small distance 

away from the enclosure. Rotate the 
DCW so that the midrange and treble 
drivers are aligned vertically (treble 
driver on top) and remount the DCW 
plate reversing the procedure above.

Flush Mounting of the 

Enclosure

Although the 1234AC may be used 
successfully as a free standing monitor, 
flush mounting is strongly recommended 
for acoustical reasons. Flush mounting 
improves the bass response and efficiency 
and also enhances the midrange transient 
and frequency response. 

Summary of Contents for SAM 1234AC

Page 1: ...Genelec 1234AC Smart Active Monitor Operating Manual 1234AC ...

Page 2: ... 4 pole Speakon cables One 10 m 32 ft 9 in RJ45 cable One 5 m 16 ft 4 in RJ 45 cable The 10 m cables are designed to go between the amplifier and the monitor enclosure If you need to make custom length cables for this please connect the Speakon cables pin to pin and see Table 1 for recommended wire gauges Amplifier Positioning The RAM XL amplifier is encased in a standard 19 3U rack case The cooli...

Page 3: ...acoustically hard and therefore reflective The monitor mounting wall should be angled so that the monitors are correctly aimed Great care should be taken over how the monitor is mounted into the solid and sturdy wall structure Note the following A space 50 100 mm 2 4 in wide can be left around the monitor enclosure Cover the space around the enclosure with a facing panel this should be fixed to th...

Page 4: ...rom the Network Adaptor to the CONTROL NETWORK connectors of the RAM XL modules and then on to the remaining monitors in the controls room The actual order of the daisy chain is not important such that if the computer is in the control room and the RAM XL modules are in a machine room they can be networked last in the chain Run the final network cable to control network input of the GLM Adapter de...

Page 5: ...ing LED Woofer Connector A standard four pole Speakon cable connects to the woofers LOUDSPEAKER CONNECTORS WOOFER MIDRANGE TWEETER WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE RACCORDÉ À LA TERRE AVERTISSEMENT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ CET APPAREIL DOIT ÊTRE RISQUE DE CH...

Page 6: ...accordance with international safety standards to ensure safe operation and to maintain the monitor under safe operating conditions the following warnings and precautions must be observed Servicing and adjustment must only be performed by a certified Genelec service The monitor enclosure or the RAM XL amplifier unit must not be opened Do not use this product with an unearthed mains cable or a main...

Page 7: ...s guaranteed for a period of two years against faults in materials or workmanship The guarantee can be extended by three years by registering the product at www genelec com Refer to supplier for full sales and guarantee terms Figure 11 Horizontal directivity characteristics of the 1234AC enclosure in horizontal configuration The lower curve is the monitor s power response Figure 9 Vertical directi...

Page 8: ... enclosure dimensions Height Width Depth 489 mm 191 4 in 1210 mm 475 8 in 412 mm 161 4 in Amplifier dimensions Height Width front plate Width casing Depth 3U 132 mm 53 16 in 483 mm 19 in 425 mm 163 4 in 286 mm 111 4 in 1234AC Bass amplifier short term output power Midrange amplifier short term output power Treble amplifier short term output power 2 x 750 W 400 W 250 W Long term output power is lim...

Reviews: