11
SYSTEM SPECIFICATIONS
S360A
Lower cut-off frequency, –6 dB
≤ 36 Hz
Upper cut-off frequency, –6 dB
≥ 22 kHz
Accuracy of frequency response, ± 2.0 dB
39 Hz – 19 kHz
Maximum short term sine wave acoustic output on axis in half space, averaged from
100 Hz to 3 kHz at 1 m
≥ 118 dB SPL
Maximum long term RMS acoustic output in the same conditions with IEC weighted
noise (limited by driver protection circuit) at 1 m
≥ 112 dB SPL
Maximum peak acoustic output per pair in a listening room with music material at 1 m
≥ 128 dB SPL
Self generated noise level in free space at 1 m on axis (A-weighted)
≤ 10 dB
Harmonic distortion at 95 dB SPL at 1 m on axis
Freq: 50…100 Hz
100 Hz...5 kHz
> 5 kHz
< 1 %
< 0.5 %
< 1.5 %
Drivers
Bass
Treble
250 mm (10 in) cone
Compression driver 44 mm (1.7 in) into a 25 mm (1 in) throat
Weight
30 kg (66 lb)
Dimensions
Height
Width
Depth
530 mm (20
7
/
8
in)
360 mm (14
3
/
16
in)
360 mm (14
3
/
16
in)
* The notch and shelving filters adjustments, AutoCal
TM
and GLM
TM
manual system calibration features are part of the Genelec Loudspeaker Manager (GLM
TM
) software
AMPLIFIER SECTION
SIGNAL PROCESSING SECTION
S360A
Bass amplifier short term output power
Treble amplifier short term output power
(Long term output power is limited by driver protection circuitry)
250 W
100 W
Amplifier system THD at nominal output
<0.01%
Mains voltage
100-240 VAC 50/60 Hz
Power consumption
ISS active
Idle
Full output (short term)
< 1 W
11 W
230 W
S360A
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m)
Analog input gain selection
pin 1 gnd
pin 2 non-inverting,
pin 3 inverting
+25.0 dBu
-6 dBu
0, +6, +12, +18 dB
Digital signal input connector XLR female 110 Ohm
Digital signal output / Thru connector XLR male 110 Ohm
Digital audio input
Word length
Sample rate
Digital input sensitivity (100 dB SPL at 1 m)
Digital input gain selection
AES/EBU Single Wire
AES/EBU Single Wire
16 - 24 bits
32 - 192 kHz
-30 dBFS
0, +6, +12, +18 dB
Control network
Type
Connection
Proprietary GLM™ network
2 RJ45, CAT5 cables
Crossover frequency
1.4 kHz
GLM
TM
software frequency response adjustment*
Parametric notch filters
Shelving filters
16
2 LF and 2 HF
System room response calibration
Genelec GLM AutoCal™, GLM manual, Stand-alone*