background image

  variable or fi xed, consult the operating 

  manual of your processor.

•  Connect an audio frequency signal 

  generator to one of the input channels 

  used in the system.

•   Set the frequency generator to the same 

  frequency as the subwoofer crossover 

  frequency on your decoder. If a signal 

  generator is not available, you can use an

   audio test recording with a suitable range

  of test frequencies.

•  Toggle the -180° phase switch 

  ‘ON’ and ‘OFF’ and set it to the 

  position which gives the lowest 

  sound level at the listening 

  position.

•   Next toggle the -90°phase 

  switch ‘ON’ and ‘OFF’, and 

  again set it to the position 

  which gives the lowest sound 

  level.

•   Finally, set the -180°phase 

  switch to the opposite setting.

After the phase setting has been completed, 

return the speaker confi guration on the proc-

essor to its’ original settings.

Using multiple subwoofers

The HTS3B and HTS4B are equipped with 

a “LINK OUT” connector to provide an easy 

way of coupling two or more subwoofers 

together in high SPL applications. Connect 

an XLR cable from the “LINK OUT” connec-

tor of the “master” subwoofer to which the 

decoder is connected, to the XLR input con-

nector of the other, “slave” subwoofer.

When two subwoofers connected in this 

way are positioned close to one another, 

bass level increases by 6 dB. Three subwoof-

ers give an bass SPL increase of 9,5 dB and 

four subwoofers 12 dB compared to a single 

subwoofer. Adjust the sensitivity control of all 

subwoofers in the group to match the SPL 

level of the main monitor system. Note that 

the sensitivity setting must be the same on 

all subwoofers.

Autostart and remote control

HTS3B and HTS4B are equipped with an 

“AUTOSTART” function, which automatically 

turns the amplifi er to “STANDBY” mode if 

an input signal has not been detected for 

approximately 30 minutes, and back to 

“ON” mode when the signal returns. The 

function can be deactivated by turning the 

“AUTOSTART” dip switch to “OFF”. A two-

colour LED on the amplifi er panel indicates 

the amplifi er status: green for “ON” and 

yellow for “STANDBY”. 

The amplifi er mode can also be switched 

by  a remote control unit connected to the 

respective inputs on the amplifi er. Two pairs 

of connectors are provided, 1 and 2 for a 

12 V DC trigger type remote control, and 3 

and 4 for an external switch or relay type 

control. Switch the “REMOTE CONTROL” 

dip switch to “ON” to activate this function. 

Do not connect two remote controls to the 

subwoofer at the same time. Remote control 

overrides the “AUTOSTART” function.

Automatic protection circuits

Both HTS3B and HTS4B subwoofers have 

protection circuits against speaker driver 

thermal overload and amplifi er overheating. 

The protection system resets automatically 

so that the user only has to turn the input 

level down to ensure that it does not reac-

tivate.

Safety considerations

Genelec HTS3B and HTS4B comply with inter-

national safety standards. However, to ensure 

safe operation and maintain the equipment in 

safe operating condition the following warn-

ings and cautions must be observed.

•  Servicing and adjustment must only be 

 

performed by qualifi ed service personnel. 

•  Opening the amplifi er panel is strictly 

 

prohibited except by qualifi ed service 

 

personnel. 

•  Do not expose the subwoofer to water or 

 

moisture. Do not place any objects fi lled 

 

with liquid, such as vases on the 

 

subwoofer or near it. 

•  Always use a mains power connection 

 

with protective earth. Failing to do this 

 

may lead to personal injury.

•  Note that the amplifi er is not completely 

 

disconnected from the AC mains service 

 

unless the mains cable is removed from 

 

the amplifi er or the mains outlet.

Warning!

This equipment is capable of delivering sound 

pressure levels in excess of 85 dB, which may 

cause permanent hearing damage.

Maintenance

There are no user serviceable parts inside 

the subwoofer. Any maintenance of the unit 

must only be performed by qualifi ed service 

personnel. 

Guarantee

This product is supplied with two year guaran-

tee against manufacturing faults or defects that 

might alter the performance of the unit. Refer to 

supplier for full sales and guarantee terms. 

Figure 1. Connectors and controls of the HTS3B.

Remote

control type

Pole or
contact

Connect to

remote control

input pin no.

+

1

12 V DC
remote
control

-

2

Contact 1

3

External
switch or
relay

Contact 2

4

Connect only one remote control unit at a time

Table 1. Remote control connectors of the 

HTS3B and HTS4B 

CAL POSITION
ALL CONTROLS : OFF
INPUT SENSITIVITY : -6dBu

FOR A FLAT FREE FIELD RESPONSE
SET ALL TONE CONTROLS TO OFF.

ROOM CONTROL SETTINGS

REFER TO THE OPERATING MANUAL FOR SUGGESTED
CONTROL SETTINGS.

1

SENSITIVITY FOR

100dB SPL@1m

ENSURE THAT THE CORRECT
VOLTAGE IS SELECTED BEFORE
CONNECTING TO THE MAINS
SUPPLY.

THIS EQUIPMENT IS CAPABLE OF
PRODUCING SOUND PRESSURE
LEVELS IN EXCESS OF 85dB WHICH
MAY CAUSE PERMANENT HEARING
DAMAGE.

DO NOT EXPOSE TO WATER OR
MOISTURE.

MAINS
VOLTAGE
SELECTOR

DO NOT USE BOTH INPUTS
AT THE SAME TIME

IT IS FORBIDDEN TO UNDO ANY
SCREWS ON THIS EQUIPMENT.
SERVICING AND ADJUSTMENT
MUST ONLY BE CARRIED OUT BY
QUALIFIED SERVICE PERSONNEL

.

NEVER OPERATE THIS EQUIPMENT
WITHOUT A PROPER EARTHED
MAINS CONNECTION.

ELECTRIC SHOCK HAZARD!

WARNING

OUT

PIN

1

2

3

SIGNAL GND +

-

IN

1

2 3

2

3

1

2

XLR INPUT

LINK OUT

-3

+6

RCA INPUT

dBu

+9

+12

-6

+3

0

SWITCH THE REMOTE CONTROL DIP
SWITCH ON WHEN USING REMOTE
CONTROL.

GREEN =
NORMAL
OPERATION

YELLOW =
STANDBY

SERIAL
NUMBER

ON

MAINS INPUT
50 / 60 Hz
200 Watts
115 / 230 V~

18Hz

120Hz

GENELECR

HTS3B ACTIVE HOME THEATER SUBWOOFER

SW2
OFF

ON

OFF

ON

PHASE AT CROSSOVER

SW1
OFF
OFF

ON
ON

PHASE

-90°

-180°
-270°

-10

SW5
OFF
OFF
OFF

ON
ON
ON

SW3
OFF

ON

OFF
OFF
OFF

ON

ROLL-OFF

0dB

-2dB
-4dB
-6dB
-8dB

-10dB

SW4
OFF
OFF

ON

OFF

ON
ON

BASS ROLL-OFF

0

-4

-2

-6

-8

dB

MAGNETICALLY SHIELDED

www.genelec.com

MADE IN FINLAND

REMOTE CONTROL OVERRIDES
AUTOSTART FUNCTION.

AUTOSTART SETS THE AMPLIFIER TO
STANDBY MODE WHEN THERE IS NO
SIGNAL.

ALL OFF

CONNECTOR
PIN NO.

-4 dB
-6 dB

-2 dB

ROLL-OFF

REMOTE CONTROL

POWER

AUTOSTART

PHASE

0/-180 DEG

0/-90 DEG

ON

1

2

3

4

+ GND

OFF

REMOTE
CONTROL
INPUTS

AMPLIFIER MODE

PIN 1 HIGH: ON
PIN 1 LOW: STANDBY

CONTACT CLOSED: ON
CONTACT OPEN: STANDBY

DO NOT USE BOTH REMOTE CONTROL
TYPES AT THE SAME TIME.

3

EXTERNAL SWITCH

4

OR RELAY

REMOTE CONTROL TYPE

12 V DC REMOTE

1

+

2

GND

XLR INPUT,
LINK OUT AND
RCA INPUT
CONNECTORS

SENSITIVITY
ADJUSTMENT

PHASE, BASS ROLL-OFF,
AUTOSTART AND REMOTE
CONTROL SWITCHES

MAINS VOLTAGE
SELECTOR,
CONNECTOR
AND SWITCH

Reviews: