background image

English 5

Safety Considerations

The 8320A and 8330A have been designed in ac-
cordance with international safety standards. The 
following warnings and cautions must be observed 
to ensure safe operation and to maintain the moni-
tor under safe operating conditions:

• 

Servicing must only be performed by qualified 
service personnel. The monitor must not be 
opened.

• 

Do not use the monitor with an unearthed 
mains cable or an unearthed mains connection.

• 

Do not expose the monitor to water or moisture. 
Do not place any objects filled with liquid, such 
as vases, on the monitor or near it. 

• 

This monitor is capable of producing sound 
pressure levels in excess of 85 dB, which may 
cause permanent hearing damage.

• 

Free flow of air behind the monitor is necessary 
to maintain sufficient cooling. Do not obstruct 
airflow around the monitor.

• 

The device is not completely disconnected from 
the AC mains service unless the mains power 
cord is detached from the device or the mains 
outlet.

Guarantee

This product is guaranteed for a period of two years 
against faults in materials or workmanship. Refer to 
supplier for full sales and guarantee terms.

Compliance to FCC Rules

This device complies with part 15 of the FCC Rules. 

Operation is subject to the following two conditions: 

This device may not cause harmful interference, and this 

device must accept any interference received, including 

interference that may cause undesired operation. 

Note: This equipment has been tested and found to 

comply with the limits for a Class B digital device, pur-

suant to part 15 of the FCC Rules. These limits are de-

signed to provide reasonable protection against harmful 

interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency ener-

gy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that 

interference will not occur in a particular installation. If 

this equipment does cause harmful interference to ra-

dio or television reception, which can be determined by 

turning the equipment off and on, the user is encour-

aged to try to correct the interference by one or more of 

the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and 

receiver. 

Connect the equipment into an outlet on a circuit differ-

ent from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV techni-

cian for help

Modifications not expressly approved by the manu-

facturer could void the user’s authority to operate the 
equipment under FCC rules.

Summary of Contents for 8320A

Page 1: ...8320A 8330A Operating Manual ...

Page 2: ...tor is supplied with a mains cable 5 me ter RJ45 cable and an operating manual Connections Before connecting switch off the monitors and the signal source Once all the connections have been made the monitors can be switched on Mains Power The power switch is located on the back panel see Figure 2 Connect the monitor to a mains socket having a protective earthed connection Do not connect to an unea...

Page 3: ...HOC ÉLECTRIQUE NE PAS DIGITAL IN 292 8330T 6 ANALOG IN DIGITAL OUT GND 2 3 1 1 2 3 GND IN OUT GLM NETWORK CONNECTORS MAINS INPUT POWER SWITCH SIGNAL CONNECTORS DIGITAL IN DIGITAL OUT ANALOG IN Figure 3 GLM Network Adapter cabling Audio cabling is not shown LISTENING POSITION MICROPHONE GLM NETWORK GLM NETWORK GLM NETWORK USB Digital Audio Input The 8330A digital audio input DIGITAL IN accepts a ma...

Page 4: ... the monitors at an equal distance from the listening position and symmetrically relative to the room walls Place the listening position on the room front back centreline and the monitors at an equal distance from this centreline Minimise Reflections Acoustic reflections are created by objects close to the monitors Such objects can be desks cabi nets computer monitors etc Acoustic reflections can ...

Page 5: ...ation is subject to the following two conditions This device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pur suant to part 15 of the FCC Rules These limits are de signed to provide reasonable prot...

Page 6: ...6 English Figure 4 Horizontal and vertical directivity plots of the 8320A and 8330A ...

Page 7: ...cone 19 mm 3 4 in metal dome Weight 3 2 kg 7 0 lb 5 5 kg 12 1 lb Dimensions Height including Iso Pod table stand Height without Iso Pod table stand Width Depth 242 mm 91 2 in 230 mm 91 16 in 151 mm 6 in 142 mm 55 8 in 299 mm 1113 16 in 285 mm 111 4 in 189 mm 77 16 in 178 mm 7 in Bass amplifier short term output power Treble amplifier short term output power 50 W 50 W Total harmonic distortion at n...

Page 8: ...genelec com In China Beijing Genelec Audio Co Ltd Room 101 1st floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com Figure 5 Frequency response plots in horizontal plane of the 8320A and 8330A The lower curve is the monitor s power response 20 20k 50 100 200 500 1k 2k 5k 10k Hz Ge...