AMPLIFIER SECTION

CONNECTORS

SYSTEM SPECIFICATIONS

5050A

Free field frequency response (± 3 dB)

Main 26 Hz...85 Hz 
LFE 26 Hz...120 Hz

Maximum short term sine wave SPL output 
averaged from 30 to 85 Hz, measured in half 
space at 1 meter

99 dB

Maximum peak SPL output with random pink 
noise, measured in half space at 1 meter

104 dB

Self generated noise level in half space at 1 m 
on axis (A-weighted)

≤ 15 dB

Driver, magnetically shielded

205 mm (8")

Passive radiators

2 x 205 mm (8”)

Weight

15 kg (33 lb)

Dimensions   

Height
Width
Depth

332 mm (13

1

/

16

”)

325 mm (12

3

/

4

”)

330 mm (13”)

If the subwoofer is flush mounted into a wall or a cabinet, the recess must 
be 10 cm (4”) wider, higher and deeper than the subwoofer itself to allow 
sufficient clearance for the passive radiators and air circulation for cooling.

5050A

Amplifier short term output power
(Long term output power is limited by driver 
unit protection circuitry)

70 W

Amplifier system THD at nominal output

≤ 0.08 %

Mains voltage

100, 120 or 230 V

Power consumption (average)

Idle
Full output

11 VA
120 VA

Selectable Autostart function for signal sensing Standby/On switching

5050A

Main channels IN/OUT, LFE channel IN and 
LINK OUT unbalanced female RCA 
connectors

pin
ring 

+
gnd

LFE IN Balanced female XLR Input connector

pin 1 
pin 2
pin 3

gnd
+
-

Input impedance

10 kOhm

Input level for 100 dB SPL output @ 1 m

Variable from +12 to -6 
dBu

LINK OUT gain

0 dB

Main channel OUT gain

0 dB

CROSSOVER SECTION

5050A

Subsonic filter (18 dB/octave) below

26 Hz

Crossover frequency, (sub/main channels)

85 Hz

LFE channel cutoff frequency

120 Hz

Midband rejection > 400 Hz

> 50 dB

Bass Roll-Off control operating range 
in 2 dB steps

From 0 to -6 dB @ 27 Hz

Phase matching control in 90° steps 

From 0 to -270° @ 85 Hz