5050A Operating Manual
Genelec Document D0065R001. Copyright Genelec Oy 11.2005. All data subject to change without prior notice
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, U.S.A.
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]
In China please contact:
Genelec China Representative Office
Soho New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, CHINA
Phone +86 10 8580 2180
Fax +86 10 8580 2181
AMPLIFIER SECTION
CONNECTORS
SYSTEM SPECIFICATIONS
5050A
Free field frequency response (± 3 dB)
Main 26 Hz...85 Hz
LFE 26 Hz...120 Hz
Maximum short term sine wave SPL output
averaged from 30 to 85 Hz, measured in half
space at 1 meter
99 dB
Maximum peak SPL output with random pink
noise, measured in half space at 1 meter
104 dB
Self generated noise level in half space at 1 m
on axis (A-weighted)
≤ 15 dB
Driver, magnetically shielded
205 mm (8")
Passive radiators
2 x 205 mm (8”)
Weight
15 kg (33 lb)
Dimensions
Height
Width
Depth
332 mm (13
1
/
16
”)
325 mm (12
3
/
4
”)
330 mm (13”)
If the subwoofer is flush mounted into a wall or a cabinet, the recess must
be 10 cm (4”) wider, higher and deeper than the subwoofer itself to allow
sufficient clearance for the passive radiators and air circulation for cooling.
5050A
Amplifier short term output power
(Long term output power is limited by driver
unit protection circuitry)
70 W
Amplifier system THD at nominal output
≤ 0.08 %
Mains voltage
100, 120 or 230 V
Power consumption (average)
Idle
Full output
11 VA
120 VA
Selectable Autostart function for signal sensing Standby/On switching
5050A
Main channels IN/OUT, LFE channel IN and
LINK OUT unbalanced female RCA
connectors
pin
ring
+
gnd
LFE IN Balanced female XLR Input connector
pin 1
pin 2
pin 3
gnd
+
-
Input impedance
10 kOhm
Input level for 100 dB SPL output @ 1 m
Variable from +12 to -6
dBu
LINK OUT gain
0 dB
Main channel OUT gain
0 dB
CROSSOVER SECTION
5050A
Subsonic filter (18 dB/octave) below
26 Hz
Crossover frequency, (sub/main channels)
85 Hz
LFE channel cutoff frequency
120 Hz
Midband rejection > 400 Hz
> 50 dB
Bass Roll-Off control operating range
in 2 dB steps
From 0 to -6 dB @ 27 Hz
Phase matching control in 90° steps
From 0 to -270° @ 85 Hz