![background image](http://html.mh-extra.com/html/genelec/5041a/5041a_datasheet_2208760002.webp)
5041A Data Sheet
Genelec Document BBA0079001. Copyright Genelec Oy 10.2008. All data subject to change without prior notice
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, U.S.A.
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]
In China please contact:
Genelec China Representative Office
SOHO New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, China
Phone +86 10 8580 2180
Fax +86 10 8580 2181
www.genelec.com
In Sweden please contact
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email [email protected]
Amplifier Section
connectorS
SyStem SpecificAtionS
5041A
Free field frequency response (± 3 dB)
35 Hz...95 Hz
Maximum short term sine wave SPL output
averaged from 40 to 85 Hz, measured in half
space at 1 meter
105 dB
Maximum peak SPL output with random pink
noise, measured in half space at 1 meter
110 dB
Self generated noise level in half space at 1 m
on axis (A-weighted)
≤
15 dB
Drivers
2 x 165 mm (6.5")
Weight
Subwoofer enclosure
Amplifier
15 kg (33 lb)
1.4 kg (3.1 lb)
Dimensions (see Figure 1)
Subwoofer enclosure
Height
Width
Depth
Amplifier
Height
Width
Depth*
*Note that the cable connectors require at
least 100 mm (4”) of space behind the
amplifier
1170 mm (46
1
/
16
”)
346 mm (13
5
/
8
”)
82 mm (3
1
/
4
”)
177 mm (6
31
/
32
”) (4U)
54 mm (2
1
/
8
”)
260 mm (10
1
/
4
”)
5041A
Amplifier short term output power
(Long term output power is limited by driver
unit protection circuitry)
125 W
Amplifier system THD at nominal output
≤
0.05 %
Mains voltage
85-132 V or 170-265 V
according to region
Power consumption (average)
Stand by
Idle
Full output
8.5 VA
11 VA
150 VA
5041A
Input connector XLR female
pin 1
pin 2
pin 3
1, balanced
gnd
+
-
Input connector RCA female
pin 1
pin 2
1, unbalanced
gnd
+
LINK OUT connector XLR male
pin 1
pin 2
pin 3
1, balanced
gnd
+
-
Input impedance
10 kOhm
LINK OUT gain
0 dB
controlS
5041A
Input sensitivity
+12 to –6 dBu
Phase matching control in 90° steps
From 0 to -270°
Bass Roll-Off control operating range
in 2 dB steps
From 0 to -6 dB @ 35 Hz
Remote control
Remote controlled
Standby/On switching by
12 V trigger