Genelec 4020BMM Operating Manual Download Page 7

 7

AMPLIFIER SECTION 

Bass amplifier output power with an 8 Ohm load:   20 W
Treble amplifier output power with an 8 Ohm load:  20 W
Long term output power is limited by driver unit protection 
circuitry.
_____________________________________________ 
Amplifier system distortion at nominal output: 
THD 

< 0.08 % 

SMPTE-IM 

< 0.08 % 

CCIF-IM 

< 0.08 % 

DIM 100 

< 0.08 %

_____________________________________________ 
Signal to Noise ratio, referred to full output: 

 

Bass 

> 95 dB   

Treble 

> 95 dB

_____________________________________________ 
Mains voltage: 

 

 

100, 120, 220 or 230 V  

 

according to region

Voltage operating range: 

±10 %

Power consumption: 

 

Idle  

5 W

Standby 

<0,5 W   

Full output 

50 W

SYSTEM SPECIFICATIONS 

Lower cut-off frequency, –3 dB: 

< 65 Hz

_____________________________________________
Upper cut-off frequency, –3 dB: 

> 21 kHz

_____________________________________________
Free field frequency response of system: 
 

66 Hz – 20 kHz (± 2.5 dB)

_____________________________________________
Maximum short term sine wave acoustic output on axis in 
half space, averaged from 100 Hz to 3 kHz:
 

@ 1 m > 96 dB SPL

 

@ 0.5 m > 102 dB SPL

_____________________________________________
Maximum long term RMS acoustic output in same 
conditions with IEC weighted noise (limited by driver unit 
protection circuit): 

@ 1 m >  95 dB SPL

_____________________________________________
Maximum peak acoustic output per pair on top of 
console, @ 1 m distance with music material:  > 105 dB
_____________________________________________
Self generated noise level in free field @ 1m on axis:
 

< 10 dB (A-weighted)

_____________________________________________
Harmonic distortion at 85 dB SPL @ 1m on axis:
Freq: 

50…100 Hz <   3 % 

 

>100 Hz < 0.5 %

_____________________________________________
Drivers: Bass   

105 mm (4") cone 

 

Treble  

19 mm (

3

/

4

") metal dome 

Both drivers are magnetically shielded
_____________________________________________
Weight: 

3.6 kg (7.9 lb)

_____________________________________________
Dimensions:  
Height 

226 mm (8

7

/

8

”)

Width 

151 mm (6")

Depth 

142 mm (5

5

/

8

”) 

CROSSOVER SECTION 

Input connector: 
 

Balanced 10 kOhm

 _____________________________________________
 
Input level for 100 dB SPL output at 1 m: 
 

-6 dBu at volume control max 

_____________________________________________
 
Volume control range:  
 

-40 dB relative to max output 

_____________________________________________
 
Crossover frequency, Bass/Treble: 

3.0 kHz 

_____________________________________________

Treble Tilt control operating range:  

 

 

0 to –2 dB @ 15 kHz

_____________________________________________

Bass Roll-Off control operating in a –6 dB step @ 85 Hz  
_____________________________________________

Bass Tilt control operating range in –2 dB steps:  

 

 

0 to –6 dB @ 100 Hz 

_____________________________________________

The ‘CAL’ position is with all tone controls set to ‘off’ and  
the input sensitivity control to maximum (fully clockwise).

Summary of Contents for 4020BMM

Page 1: ...4020B Operating Manual ...

Page 2: ...e loudspeakers and the signal source have been switched off The power switch of the 4020B is located on the back panel see Figure 3 Connect the loudspeaker to an earthed mains connection with the supplied mains cable Never connect the loudspeaker to an un earthed mains supply or using an unearthed mains cable Audio input is via a 10 kOhm balanced con nector The connector also has two pins for 12 V...

Page 3: ... Off An acoustic measuring system such as WinMLS or comparable is recom mended for analyzing the effects of the adjust ments however careful listening with suitable test recordings can also lead to good results if a test system is not available Table 1 shows some examples of typical settings in various situations Figure 4 shows the effect of the controls on the anechoic response Treble Tilt The Tr...

Page 4: ... walls cabinets etc can cause unwanted colouration blurring of the sound im age These can be minimised by placing the loud speaker clear of reflective surfaces Minimum clearances Sufficient clearance for cooling of the amplifier and functioning of the reflex port must be ensured if the loudspeaker is installed in a restricted space such as a cabinet or integrated into a wall struc ture The surroun...

Page 5: ...tee This product is guaranteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC rules This device complies with part 15 of the FCC Rules Operation is subject to the following conditions This device may not cause harmful interference and This device must accept any interference received including interference...

Page 6: ... 100 200 500 1k 2k 5k 10k Hz Genelec Oy 4020 dBr vs freq Hz 7 Nov 12 70 65 0 60 15 30 45 Figure 4 The curves show the effect of the Bass Tilt Treble Tilt and Bass Roll Off controls on the free field response of the 4020B Figure 5 The upper curve group shows the horizontal directiv ity characteristics of the 4020B measured at 1 m The lower curve shows the system s power response ...

Page 7: ...____________ Maximum peak acoustic output per pair on top of console 1 m distance with music material 105 dB _____________________________________________ Self generated noise level in free field 1m on axis 10 dB A weighted _____________________________________________ Harmonic distortion at 85 dB SPL 1m on axis Freq 50 100 Hz 3 100 Hz 0 5 _____________________________________________ Drivers Bass...

Page 8: ......

Reviews: