1034B Data Sheet
AmpliFier Section
croSSover Section
SyStem SpeciFicAtionS
1034B
Lower cut-off frequency, -3 dB
< 32 Hz
Upper cut-off frequency, -3 dB
> 20 kHz
Free field frequency response
33 Hz - 20 kHz (±2.5 dB)
Maximum short term sine wave acoustic
output on axis in half space, averaged
from 100 Hz to 3 kHz:
@ 1m >123 dB SPL
Maximum long term RMS acoustic
output in same conditions with
IEC-weighted noise (limited by driver
unit protection circuit)
@ 1m >118 dB SPL
Maximum peak acoustic output per pair
@ 2 m from the engineer with music
material
> 125 dB
Self generated noise level in free field
@ 2 m on axis
< 15 dBA
Harmonic distortion at 100 dB SPL
Freq:
50...200 Hz
<1%
200...10 kHz <0.5
Drivers
Bass
2 x 305 mm (12”)
Mid
1 x 130 mm (5”)
Treble
1 x 25 mm (1”) metal dome
Weight
Speaker 73 kg (161 lb)
Amplifier 30 kg (66 lb)
Speaker dimensions
Height
700 mm (27
9
/
16
”)
(Horizontal mounting)
Width
890 mm (35”)
Depth
383 mm (15
1
/
16
”)
Amplifier dimensions
Height
310 mm (12
3
/
16
”)
Width
483 mm (19”)
Depth
250 mm (9
13
/
16
”) *
* Note that the cable connectors require additional
100 mm (4”) of space behind both the amplifier
and the speaker cabinet.
1034B
Bass amplifier output power with
an 8 Ohm load
Short term 2 x 400 W
Mid amplifier output power with
an 8 Ohm load
Short term 350 W
Treble amplifier output power with
an 8 Ohm load
Short term 120 W
Long term output power is limited by driver unit
protection circuitry.
Slew rate
80 V/µs
Amplifier system distortion at
THD
<0.05%
nominal output
SMPTE-IM <0.05%
CCIF-IM
<0.05%
DIM 100
<0.05%
Signal to Noise ratio,
Bass
>100 dB
referred to full output
Mid
>100 dB
Treble
>100 dB
Mains voltage:
100/200 or 115/230 V
Voltage operating range at
230 V setting
207 - 244 V (-10/+6 %)
115 V setting
104 - 122 V (-10/+6 %)
Power consumption
Idle
70 W
Full output 1000 W
1034B
Input connector: XLR female
pin 1 gnd
pin 2 +
pin 3 -
Input impedance
10 kOhm balanced
Input level for 100 dB SPL output @ 1m
variable from +6 to -6 dBu
Input level for maximum short term output
of 126 dB SPL @ 1m
variable from +32 to +20 dBu
Subsonic filter below 27 Hz
18 dB/octave
Ultrasonic filter above 22 kHz
12 dB/octave
Crossover frequencies
Bass/Mid
400 Hz
Mid/Treble 3.2 kHz
Crossover acoustical slopes
>24 dB/octave
Level control operating range
Bass
from 0 to -6 dB & MUTE
in 1 dB steps
Mid
from 0 to -6 dB & MUTE
Treble
from 0 to -6 dB & MUTE
Bass roll-off control in 2 dB steps
from 0 to -8 dB @ 32 Hz
Bass tilt control in 2 dB steps
from 0 to -8 dB @ 50 Hz
The ‘CAL’ position is with all tone controls set to ‘off’
and input sensitivity control to maximum and
corresponds to a maximally flat free field response.
Genelec Document BBA34001c. Copyright Genelec Oy 5.2006. All data subject to change without prior notice
www.genelec.com
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83 881
Fax +358 17 812 267
Email [email protected]
In the U.S. please contact
Genelec, Inc., 7 Tech Circle
Natick, MA 01760
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]
In China please contact:
Beijing Genelec Audio Co. Ltd.
Jianwai SOHO, Tower 12, Room 2306
39 East 3rd Ring Road
Chaoyang District
Beijing 100022, China
Phone +86 0 5869 7915, Fax +86 10 5869 7914
In Sweden please contact
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email [email protected]