AMPLIFIER SECTION
CROSSOVER SECTION
SYSTEM SPECIFICATIONS
Lower cut-off frequency, -3 dB:
<40 Hz
Upper cut-off frequency, -3 dB:
>22 kHz
Free field frequency response of system:
42 Hz - 21 kHz (±2.5 dB)
Maximum short term sine wave acoustic output on
axis in half space, averaged from 100 Hz to 3 kHz:
@ 1m > 113 dB SPL
@ 0.5m > 119 dB SPL
Maximum long term RMS acoustic output in same
conditions with IEC weighted noise (limited by
driver unit protection circuit):
@ 1m
>103 dB SPL
@ 0.5m >109 dB SPL
Maximum peak acoustic output per pair above
console bridge, @ 1 m from the listening position
with music material:
> 124 dB
Self generated noise level in free field @ 1m
on axis:
< 10 dB (A-weighted)
Harmonic distortion at 90 dB SPL @ 1m on axis:
Freq:
50...100 Hz
< 1%
> 100 Hz
< 0.5%
Drivers:
Bass 10" (250 mm) cone
Treble 1" (25 mm) metal dome
Both drivers are magnetically shielded.
Weight:
21,7 kg (48 Ib.)
Dimensions:
Height 495 mm (19
1
/
2
")
Width 320 mm (12
5
/
8
")
Depth 290 mm (11
7
/
16
")
Bass amplifier short term output power with a
4 Ohm load:
180 W
Treble amplifier short term output power with an
8 Ohm load:
120 W
Long term output power is limited by driver unit
protection circuitry.
Slew rate
80V/µs
Amplifier system distortion at
nominal output:
THD < 0.05%
SMPTE-IM
< 0.05%
CCIF-IM
< 0.05%
DIM 100
< 0.05%
Signal to Noise ratio, referred to full output:
Bass
> 100 dB
Treble
> 100 dB
Mains voltage:
230, 100/200 or 115/230V
according to region
Voltage operating range:
±10%
Power consumption:
Idle
20 W
Standby
<0.5 W
Full output
200 W
Input connector XLR female:
pin 1 gnd
pin 2 +
pin 3 -
Input impedance:
10 kOhm balanced
Input level for 100 dB SPL output @ 1m:
variable from +6 to -6 dBu
Input level for maximum short term sine wave output
113 dB SPL @1m:
variable from +19 to +7 dBu
Subsonic filter below 40 Hz :
18 dB/octave
Ultrasonic filter above 25 kHz:
12 dB/octave
Crossover frequency, Bass/Treble:
1.8 kHz
Crossover acoustical slopes:
24 - 32 dB/octave
Treble tilt control operating range in 2 dB steps:
from +2 to -4 dB & MUTE
Bass roll-off control operating range in 2 dB steps:
from 0 to -8 dB @ 40 Hz
Bass tilt control operating range in 2 dB steps:
from 0 to -8 dB @ 80 Hz
& MUTE
The 'CAL' position is with all tone controls set to 'off'
and the input sensitivity control to maximum (fully
clockwise).
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]
AUDIO PRECISION 1032anec
vs
02 FEB 93 18:51:59
60
65
70
75
80
85
90
80
85
90
95
LEVEL(dBr)
20
100
1k
10k
20k
FREQ(Hz)
BASS TILT
TREBLE TILT
BASS ROLL-OFF
AUDIO PRECISION 1032anec
vs
02 FEB 93 18:56:42
80
85
90
95
100
LEVEL(dBr)
20
100
1k
10k
20k
FREQ(Hz)
0°
15°
30°
45°
65
70
75
80
85
90
95
Figure 4. The upper curve group shows the horizontal directivity
characteristics of the 1032B in vertical configuration measured at 1 m.
The lower curve is a 1/3 octave band power response, measured in an
IEC approved reverberation chamber.
Figure 5. The upper curve group shows the effect of the bass tilt
control on the free field response. The lower curves show the effect
of the treble tilt and bass roll-off controls.
In China please contact:
Beijing Genelec Audio Co. Ltd.
Jianwai SOHO, Tower 12, Room 2605
39 East 3rd Ring Road
Chaoyang District
Beijing 100022, China
Phone +86 10 5869 7915, Fax +86 10 5869 7914
In Sweden please contact
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 708 7070
Fax +46 8 708 7071
Email [email protected]