![Genasun GV-10 Manual Download Page 3](http://html.mh-extra.com/html/genasun/gv-10/gv-10_manual_2208224003.webp)
the following:
WARNING: THIS UNIT IS NOT PROVIDED WITH A GFDI DEVICE.
Consult Article 690 of the National Electrical Code (or the standards in force at the
installation location) to determine whether a GFDI is necessary for your installation.
WARNING: THIS UNIT IS NOT PROVIDED WITH DISCONNECT DEVICES.
Consult
Article 690 of the National Electrical Code (or the standards in force at the installation location) to determine whether disconnect devices are necessary for your
installation.
LITHIUM WARNING:
Use caution when working with lithium systems. Genasun Li controllers use the CC/CV charging profile indicated on the controller.
CHECK the specifications of the battery pack to ensure that the CV voltage is correct. Further check that the power supplied by the solar array and Genasun controller
is within the battery specified design limits.
LITHIUM BMS WARNING:
Genasun recommends using a lithium battery with a Battery Management System (BMS) capable of disconnecting the solar charge controller
in the event that any cell in the pack is outside of its rated temperature, current, or voltage range. Failure to do so may result in property damage, injury or death.
Genasun highly recommends the use of a BMS with cell balancing. Cell balancing is mandatory for lithium iron phosphate. Use only 10-30 AWG (5.0 mm
2
max) copper
conductors suitable for a minimum of 60 degrees C. If operation at high power or at high ambient temperatures is expected, wire with a higher temperature rating
may be necessary. Recommended terminal block tightening torque: 7 in-lbs, 0.79 Nm.
Inspection & Maintenance
•
Check for animal or insect damage.
•
Inspect for corrosion / water damage.
•
Inspect the security of all connections.
• Inspect the controller at least once per year to ensure proper performance.
•
Ensure the solar array does not exceed the maximum input voltage.
•
Repair and clean as necessary.
Product Certifications
1
Safety
Conforms to:
UL STD 1741
Certified to:
CSA STD C22.2#107.1
HazLoc (C1D2)
Conforms to:
UL STD 121201
Certified to:
CSA STD C22.2#213
EMC
Conforms to:
EN 61000-6-3:2007+A1:2011
EN 61000-6-2:2005
AS/NZS 61000-6-3:2012
EMC
Conforms to:
FCC (CFR Title 47) Part 15 Radio frequency
Devices, Subpart B - Unintentional Radiators.
Tested for compliance.
Restriction Hazardous of Substances
Conforms to:
EN 50581:2012
(1) The GV-10-PCB models are ETL Recognized Components for safety (UL1741).