CALIBRATION PROCEDURE

IMPORTANT: 

 Do not attempt to recalibrate this scale 

without first having a 500g calibration weight in your 
possession. This weight is available as an optional 
accessory from your scale supplier (Item #9745). Note 
that (20) US nickels equal 100g, and if you do not have 
the necessary calibration weight you may in its place 
substitute the appropriate number of nickels.  Also, 
always check to confirm the batteries have sufficient 
power or the calibration procedure may not work 
properly.

1. If the factory’s preset calibration requires adjusting 

as indicated by the accuracy of the scale being 
off by more than +/- 0.1g, place the scale on a 
stable, flat surface which is free from vibrations and 
excessive air currents. 

  
2. With the scale off, press both the <  /T > and the 

“M” button down. A random number will appear on 
the display.  

Summary of Contents for PLATINUM V600M

Page 1: ...V SERIES mini scale PLATINUM V600M...

Page 2: ...t sized scale at a real value of a price The Platinum V600M weighs in g dwt oz ozt and features a bright blue backlit LCD display stainless steel weighing platform mini rectangular design with unique...

Page 3: ...V Series Mini Scale 3 weighing platform This will come in handy for holding gold jewelry findings silver beads and more while it is on the weighing platform Please read all instructions prior to oper...

Page 4: ...bottom of the scale slide off the battery compartment door and carefully insert the 2 supplied AAA batteries into the battery compartment Replace the battery compartment door 1 T ON OFF Push the T but...

Page 5: ...play will show a negative weight equal to the weight of the tray or whatever was on the platform After placing the tray back on the weighing platform you may then place the item that you wish to weigh...

Page 6: ...weight you may in its place substitute the appropriate number of nickels Also always check to confirm the batteries have sufficient power or the calibration procedure may not work properly 1 If the fa...

Page 7: ...calibration was not successful please repeat this procedure again until the calibration procedure has been successfully completed SPECIFICATIONS 1 Capacity 600g 2 Readability 0 1g 3 Units of Measure g...

Page 8: ...e was the cause of the defect the scale may be repaired or replaced at the factory s sole discretion No other written or implied warranty shall apply In the unlikely event of a scale defect and provid...

Page 9: ...pay any related shipping charges and any related taxes duties for the respective destination country No contaminated scale will be accepted and if received in this condition it will automatically be...

Page 10: ...GemOro GemOro Platinum Scales 10455 Olympic Drive Dallas Texas 75220 USA Tel 800 527 0719 or 214 351 0380 Fax 800 832 9871 or 214 351 1903 www gemoroproducts com sales sykessler com...

Reviews: