Gemo DT961 Quick Manual Download Page 4

GEMO

ERROR MESSAGE

“FAiL”: Displays “FAiL” message in case of sensor failure, measurement out of range or 
hardware fails to measure input signal.

OUT CONTROL FORM; ON-OFF

OUT relay is OFF when process value (PV) is greater then or equal to SET value. OUT relay is 
ON when PV is less then or equal to (SET-Hys) value (Hys has a fixed value of 3

o

C).

CLAEANING

Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean 
the device. Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power 
supply and mains connections.

Gürbüzo

ğ

lu Elektronik San. ve Tic. Ltd. 

Ş

ti.

http://www.gemo.com.tr

Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye

e-posta: [email protected]

Tel: +90-312-3503900, Fax: +90-312-3511117