WI850A GEM-P800 Installation Instructions

8. How do I remove Keypad Sounder on

Alarm?

The keypad sounder follows the Burg Out-

put. If you need to remove the Keypad

Sounder, then you must remove the Burg

Output from that zone.

9.  Transmitters not responding?

Open Transmitter case - Keypad should go

into X-Mitter Tamper Trouble. If not:

Check Receiver Red LED should be

flashing once approx. once a  second.

Check Receiver wiring.

Check Programming of Transmitter ID.

If Keypad does go into X-Mitter Tamper

Trouble, check:

Transmitter point is programmed cor-

rectly.

Transmitter is wired correctly:

If using external switch, make sure it is

wired to point 1, and point 2 is jumped

out.

If using internal reed, make sure J1 is

cut and both Point 1 and Point 2 termi-

nals are jumped out.

10. Keypad LEDs Flicker.

The Keypad is not receiving a POLL from

the Panel.

Check Keypad wiring.

1.  The Panel is in the process of being

Uploaded/Downloaded.

2. The panel is powering up.  LED’s

will flicker until panel has reset and

is polling the keypad.

3. The connection from the control

panel to the keypad is open.

11. No Keypad Entry Sounder during En-

try Time?

The keypad sounder is turned off with the

command.  This command will

silence all Keypad sounds except keypad

sounder on alarm.  Enter 

to

turn keypad sounds back on.

12. No Keypad Chime?

The keypad sounder is turned off with the

 command.  This command will

silence all Keypad sounds except keypad

sounder on alarm.  Enter 

to turn

keypad sounds back on.

Wi850a 
page 26

Tuesday, September 16, 1997 08:01 

Summary of Contents for GEM-P800

Page 1: ...GEM P800 Installation Instructions Control Panel Communicator WI850A 8 97 NAPCO 1997 Wi850a page 1 Tuesday September 16 1997 08 01 ...

Page 2: ...sion Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 8 Users Opening after Alarm Report Cancel Code For Technical Assistance Contact the NAPCO Toll Free Helpline 800 645 9440 NAPCO Security Systems Inc 333 Bayview Avenue z Amityville New York 11701 For Sales and Repairs call To...

Page 3: ... TRF12 OR BASLER 16 5 VAC 20VA Required Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A RRS KDUDFWHULVWLFV Loop Voltage 5 Volts Loop Current Zones 1 2 3 0 9 mA Zones 4 5 6 0 5 mA Loop Resistance 100Ω per zone max HYLFH 6SHFLILFDWLRQV Max keypads 4 GEM RP8 current 65 mA Max of receivers 2 GEM RECV XP8 current 65 ...

Page 4: ...eless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles Software with Interface for IBM PC Compatibles Local Download cable GEM RECV XP8 GEM TRANS2 GEM KEYF GEM SMK GEM PIR GEM DT GEM GB RB1000 Veriphone PCD3000 PCI2000 3000 PCL2000A LVWLQJV DQG SSURYDOV UL HOUSEHOLD ...

Page 5: ...te Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or method of establishing a connection The power up method is recommended if the panel is attempting to report Remote Downloading Wire as shown in Figure 2 The panel can be remotely download uploaded using any one of the following methods 1 The method 2 Call in method 3 Answering Mac...

Page 6: ...tectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fire Pro tection Association Batterymarch Park Quincy MA 02269 for additional information including proper mounting methods LULQJ Grounding the Panel Connect the control panel EARTH GROUND screw to a metal col...

Page 7: ... 2SHUDWLRQ Keypad zone LEDs indicate zone status ARMED STATUS and SYSTEM LEDs pro vide system status The keypad sounder pro vides feedback beeps for correct and incorrect entries Keypad Sounder 3 QUICK BEEPS Panel Armed System ON Chime ON Fault Find Mode ON Keypad Sounder ON Zone Bypassed 6 QUICK BEEPS Panel Disarmed System OFF Chime OFF Fault Find Mode OFF Keypad Sounder OFF Zone Un Bypassed 1 SE...

Page 8: ...wer Zones can be bypassed when the or keys on the Keyfob have been pro grammed for Interior 81 84 Zones pro grammed as Home Away with Delay Zones can be armed regardless of the state of the Exit Entry Zones when the or keys on the Keyfob have been programmed for Full Set 81 84 To arm the system with all zones pro tected press the key Press and hold the or key for 1 5s to fully set the system The L...

Page 9: ...nes From the Keypad Press to return protection to Home Away with Delay Zones that have been automatically bypassed Three min utes are allowed to walk through Exit Entry and Exit Entry Follower Zones Using A Keyfob GEM KF All zones in the system can be armed regardless of the state of the Exit Entry Zone when arming with a Keyfob and using an AUX key programmed as Full Set Press and press and hold ...

Page 10: ...d keypad LEDs for 2 seconds The battery is tested during a Bell Test and auto matically every 24 hours to ensure proper bat tery operation under load The Alarm output requires a battery in order to supply the specified output If the battery cannot sustain the load a low battery indication will be displayed A battery test is also performed on power up after a 3 minute delay A battery test occurs ev...

Page 11: ...faulted and for 1 second when zones are restored LUHOHVV 2SHUDWLRQ 6LJQDO 6WUHQJWK While in Fault Find mode the keypad will pro vide an audible Table 6 and visual Figure 5 indication of each transmitter s signal strength The signal strength metering is based on a scale of 4 to 10 with 4 being marginal and 10 being excellent The keypad will beep out a number from 1 4 corresponding to the signal str...

Page 12: ...or Full Set 81 7 02 Exit Entry Follower Zones Entry Delay allows the user time to enter and disarm Allows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay and do not display or cause an alarm if faulted when the system powers up Pressing the key cancels...

Page 13: ...ch permits exit through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a value of 0 defaults to 60 seconds 11 Entry Delay Delay time permits entry through Exit Entry Zone s after the system is armed without setting off an immediate alarm Entry Delay allows the us...

Page 14: ...ing Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quick loader Software From the Status Screen Press T T Select Miscellaneous Control Select Test Timer Offset Enter New Test Timer Offset 12 hours Enter Xto advance the test timer due in time by 12 hours 6 VWHP HDWXUHV 20 Keypad Features 1 1 Enable Keypad Fire Additional Programming ...

Page 15: ...irp the PGM Output 1 one time when the panel is armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a AUX alarm 3 Panic Program to activate the PGM on a Panic alarm 4 Test Timer Program to activate the PGM during a Test Timer report 25 Programmable Output ...

Page 16: ...al station has this capability Instead of sending a second round to verify correct data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Handshake All receiver formats except Pager Format If programmed no Handshake Kissoff is re quired by the panel 34 Zone Report ...

Page 17: ...gram if using an Outside access number 45 Communicator Features 1 1 Communicator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pulse method of dialing Disable this feature to dial using only rotary dialing 3 DTMF only All attempts to communi cate dial usi...

Page 18: ...elco 1 Program to split double report to Telco 3 Refer to sections 30 through 39 5HSRUW RGHV 60 Zone Report Codes Report Code for Zones 1 through 8 4 2 format The Zone Report Code is the 1st digit of the report code sent the sec ond digit is the zone number of the report ing zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Code and does...

Page 19: ...ll users that are not se lected to report an Opening Closing 39 59 will report a Closing only when zones have been bypassed The Zone Trouble Code 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing Telco 3 see 67 1 3 Reserved 4 Reserved LUHOHVV Up to two r...

Page 20: ...tional programming required Keypad Panic 20 3 Panic Report to Telco 1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the or buttons on the Keyfob are pressed Additional programming required Keypad AUX 20 2 AUX Report to Telco 1 36 2 and or Telco 3 56 2 3 Bell ON Program a 3 in the AUX 1 and or AUX 2 option to tur...

Page 21: ...ing Features must also be se lected 92 Downloading Features 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the panel When the operator has determined that the panel has received 1 2 rings pressing the Xkey will cause the downloading com puter to immediatel...

Page 22: ...w ing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test per formed every 4 hours instead of 24 hours and Wireless Smoke Supervisory Timer is set to 4 hours Fire Bell Timing is March Time Wireless Smoke Supervisory Time is fixed at 4 hours 4 Fire Trouble on Fire LED Normally all troubles are dis...

Page 23: ...rting The following system troubles when enabled to report to Telco 1 37 3 or Telco 3 57 3 will send the report code programmed in Trouble Report 63 if reporting using a pulse format System Trouble Pulse Report Code Bell Cut F1 2 Wire Fire Trouble F1 Rcvr Fail to Respond F1 Receiver Tamper F1 Receiver JAM F1 Tx Low Battery F1 Tx Supervisory Failure F1 Smoke Low Battery F1 Smoke Sup Failure F1 If r...

Page 24: ...the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 8 Wireless Transmitter Low Battery The battery in the wireless transmitter is low and should be replaced This transmitter is on the zone corresponding to the number of the zone light flashing The replacement battery for the GEM Tr...

Page 25: ... through the Bell circuit for supervision To eliminate this cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel incorporates advanced circuitry which automatically limits the cur rent when an over current condition exists without the use of traditional fuses The circuit will restore automatically when the over current conditi...

Page 26: ...is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 termi nals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Check Keypad wiring 1 The Panel is in the process of being Uploaded Downloaded 2 The panel is powering up LED s will flicker until panel has reset and is polling the keypad 3 The connection from the control panel to...

Page 27: ...D WATER GROUND CONNECTION USE ONLY COLD WATER PIPE OR BURIED GROUND ROD USE AT LEAST 16 AWG WIRE TELCO RED GRN GRAY BRN FIRE PWR 2 A P 0 REMOTE BUS ZONE 3 E E ZONE 6 ZONE 5 Z ZONE 1 E ZONE 4 Z E 5 51 GEM RP8 Fire Loop In 4 Wire Fire Wiring Power Out Power Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire Normally Open Zone Wiring Wire the no...

Page 28: ...sting and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that t...

Reviews: