8.0 - SETTING OF PARAMETERS

9.0 - TESTING

!
!
!

!
!
!
!

!

Press one of the two push-buttons on the control unit to enter in the programming mode.
Select parameter “15” (see “Setting of parameters”).
Press and keep pressed one of the two push-buttons and select test (1 for testing the sensors or 3
for detection speed).
Press and keep pressed one of the two push-buttons; the display will show “--”.
Proceed with the sensors test; the system will indicate the value detected in real time.
Reprogram setting of parameter to “0”.
Press one of the two push-buttons and keep it pressed until the previously selected parameter is
displayed (15).
The system will automatically exit the programming mode 10 seconds after the push-button has
been pressed.

Nr.

01

03

07

11

12

15

16

PARAMETERS

Volume of buzzer

Detection range of front corner sensors

STOP zone of front corner sensors

Number of speed signal pulses

Delay of front sensors deactivation

Service display (testing)

Continuous detection

RANGE

0, 1, 2 (

)

From 50 to 95 cm

From 25 to 50 cm

From 1 to 99 (

)

0 or from 10 to 60 sec. (

)

0, 1, 3 (

)

0, 1 (

)

Ref.1

Ref.2

Ref.3

Ref.4

Ref.5

SETTING

2

55

25

3

00

0

0

Ref.1
Ref.2

Ref.3

Ref.4

Rif.5:

: 0 = deactivated, 1 = low, 2 = high.
:

3.3.

: by setting “00”, the system is activated every time ignition is turned on; to deactivate, press the

push-button with the LED. Press again, to reengage the sensors.

: 0 = not activated, 1 = distance from the closest front obstacle, 3 = vehicle speed (in km/h, for

programming refer to parameter 11).
0 = deactivated, 1 = activated.

by setting “1”, the system activates also when reverse gear is engaged. For connections and

operation see par. 6.0 and

10.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT

(WEEE) DIRECTIVE

The present device does not fall within the scope of Directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE) as specified in art. 2.1 of L.D. no. 151 of 25/07/2005.

7.0 - PROGRAMMING

The display will indicate:

FS: Factory Setting, standard adjustment , “Factory parameters”.

CS: Custom Setting, user-chosen adjustment, “Custom Parameters”.

Only expert users should modify these settings to avoid malfunctions of the parking

system.

!

To activate the programming procedure proceed as follows:

Press one of the two push-buttons on the control unit and keep it pressed for at least two seconds;

the system will activate and enter in the programming mode.

Press the two push-buttons on the control unit and keep them pressed for more than

two seconds to reset all the factory settings (FS).

!

Press the right push-button to go to the next

parameter.

Press the right push-button to increase the value

of the parameter.

When the parameter you want to modify is displayed, press one of the push-buttons and keep it

pressed until the display starts to blink; at this point you can modify the parameter.

Press one of the two

on the control unit and keep it pressed for at least two seconds

to register the value.

The display will stop blinking and the selected parameter will be displayed.

push-buttons

If no button is pressed within10 seconds, the system will exit the programming mode.

Press the left push-button to go to the previous

parameter.

Press the left push-button to decrease the value

of the parameter.

Reviews: