GEMAŞ Genel Mühendislik Mekanik San.veTic.A.Ş.
İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY
Tel:0232 799 0 333 Fax:0232 799 0 330 www.gemas.com.tr
4
4
EN
GEMAŞ SPIRON-D/M Installation and Instruction Manual
V3.1
2.INSTALLATION
2.1.
Plumbing Installation
• Piping should be done before the electrical installation. The electric heater should be placed in the
pipe to the pool in a horizontal position and after the filter. In this way, it is ensured that it is
constantly filled with water.
• Do not put a slide valve between the heater and the pool. When it is necessary to put a valve,
use a check-valve.
• For the flow switch to operate, the heater must be positioned and installed in the correct
direction. Otherwise, the product may malfunction.
• Chlorination, acidity regulation, etc. to prevent corrosion. should be done after the heater in the
direction of the water flow.