3. INSTALLATION 

Normally the PUMPEX swimming pool pumps 

are installed between the skimmer/balance 

tank and the swimming pool filter. 

The pump should be placed on a flat, solid 

foundation with the shaft in horizontal 

position and the prefilter cover uppermost. It 

must be possible to remove the transparent 

cover so that the prefilter basket can be 

removed for cleaning. 

The suction pipe must have as minimum the 

same diameter as the pump suction line with 

continuous slope in order to avoid long 

priming times. If the suction line exceeds 10 

meters, the extra pressure loss should be 

considered.  

The pipes should be installed to avoid any air 

leaksin its interior. The following drawing 

shows a correctly fitted piping. 

 

The pipes should be fitted in such a way that 

any pressure varioation caused by 

temperature changes do not effect the pump. 

If the piping is very long and/or high support 

the pump in front and behind. It is 

reccomendable to put a retention or check 

valve at the outlet. 

 

In case of using a suction hose, it must be non-

compressible (with a reinforcement spiral). 

The suction pipe/hose should be the shortest 

possible in order to assure optimum working 

conditions. 

It’s recomme

ndable to install shutting valves 

the both sides in order to isolate the pump. 

Note: The pump does not allow to work with 

closed discharge valve as it may cause an 

increase of the temperature and steam 

formation which can damage the pump.  

If there is any possibility of operating the 

pump with discharge valve closed, it’s 

necessary to connect one bypass/mud valve 

on the discharge pipe in order to assure a 

minimum liquid flow through the pump.

 

 

Summary of Contents for PUMPEX-100M

Page 1: ...GEMAS COUNTER CURRENT SYSTEM USER MANUAL ...

Page 2: ...e 50 C 2 2 Water Temparature From 0 C to 50 C 2 3 Maximum working pressure permitted 2 Bar Note The ram crash to be lower that 3kgs 2 4 Maximum inlet pressure When the pump Works with a closed valve the inlet pressure should be lower than the maximum working pressure permitted always 2 5 Minimum suction pressure Type Maximum Suction Maximum Autosuction Pumpex 5m 4 m 2 6 Self Priming The PUMPEX pum...

Page 3: ...g The pipes should be fitted in such a way that any pressure varioation caused by temperature changes do not effect the pump If the piping is very long and or high support the pump in front and behind It is reccomendable to put a retention or check valve at the outlet In case of using a suction hose it must be non compressible with a reinforcement spiral The suction pipe hose should be the shortes...

Page 4: ...TIONS Please make sure that the electrical supply is interrupted nefore removing the connection case cover or before any moving or disassembling of the pump Electrical connections must be done by a Professional and according to the local standarts The pump must be connected to an external switch The voltage and frequency are marked on the characteristics plate Please make sure that the motor is su...

Page 5: ... is isterrupted and it is not possible to be connected accidentally before to start working with the pump The filter basket must be checked daily and cleaned if necessary Before opening the prefilter cover please close the suction and discharge valves After the filter basket cleaning clean also the filter cover gasket and put it in its place Then check if the pump housing is full of water and if s...

Page 6: ...ANCE Please make sure that the electrical supply is interrupted and it is not possible to be accidentaly connected before the pump to start working The pump is designed to operate maintenance under normal working conditions The motor bearings are permanently lubricated ...

Page 7: ......

Page 8: ......

Page 9: ...INSTALLATION MUST BE DONE ACCORDING TO BELOW INSTRUCTION ...

Page 10: ......

Page 11: ... and the inside of the socket using sand paper or emery cloth up to the entry mark 4 Clean both surfaces and remove all dust grease and swarf using a dry clean cloth and cleaner 5 Stir adhesive thoroughly 6 Apply adhesive without delay after cleaning using a flat clean brush Apply an even unbroken layer brushing axially to the pipe end and socket mouth with a heavier layer on the pipe Where loose ...

Page 12: ...on the containers When laying continuous runs of pipe joints may be made quicker than the setting times advised above The joint will not be disturbed with long lengths providing that the pipe is not twisted or the previously made joint lifted out of place Rubber Ring Joints Ensure that the spigot and socket are free from dust grit grease and as dry as possible Insert pipe into the socket without s...

Reviews: