GEMAR Lumitec IRIDIUM Stage Studio Manual Zoom Fresnel User Manual Download Page 7

 

 

5

 

 

 

3. Description 

 

Product features

 

 

Made  by  fire

-

resistant  Nylon  material  and  Aluminum  which  makes 

the lamp more lighter

 

 

 

Good performance of cooling system with the quiet fan

 

 

 

DMX controlled operation, possible work with any commercial 

DMX512 controller

 

 

 

Rail

-

type hanging bracket, bracket position can be adjusted

 

 

 

 

Different dimmer curves and dimmer speed adjustable

 

 

 

Flicker free projection 

 

 

 

Rotatable barn doors, color filter optional

 

 

 

Ready for connection with power cord with safety

-

plug

 

 

 

Overview

 

 

 

Summary of Contents for IRIDIUM Stage Studio Manual Zoom Fresnel

Page 1: ...IRIDIUM Stage Studio Manual Zoom Fresnel USER MANUAL ...

Page 2: ...For safety please read this user manual carefully before initially start up ...

Page 3: ...TENTS 1 Introduction 2 2 Safety instructions 3 3 Description 4 Products features 4 Overview 4 4 Installtion 5 Overhead rigging 5 DMX512 connection 5 Power Input 6 5 Operation 6 8 Control board 7 DMX modes 8 ...

Page 4: ...important information about the installation usage and maintenance of the unit Please strictly follow it The product conforms to the international standard DMX512 agreement The products can be controlled in signal use and also can be controlled in many units Sleek and stylish precise and accurate optical system design bring and clear light effects All above makes our products applicable to be used...

Page 5: ...mpliance with the CE ROHS Standard The product belongs to our company The intellectual property is exclusively reserved We will file a lawsuit on condition that it is illegally copied and imitated 2 Safety instructions WARNING Do not open this device there is no user serviceable parts inside Risk of electric shock ...

Page 6: ...ain when mounting this device overhead Do not operate this device outdoors or in any location where dust excessive heat water or humidity may affect it Do not operate this device if the housing lenses or cables appear damaged Do not connect this device to a dimmer or rheostat ONLY connect this device to a grounded and protected circuit ONLY use the hanging bracket to carry this device In case of a...

Page 7: ...g system with the quiet fan DMX controlled operation possible work with any commercial DMX512 controller Rail type hanging bracket bracket position can be adjusted Different dimmer curves and dimmer speed adjustable Flicker free projection Rotatable barn doors color filter optional Ready for connection with power cord with safety plug Overview ...

Page 8: ...d rigging The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1hour without any harming deformation The installation must always be secured with a secondary safety attachment This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main ...

Page 9: ...ty instructions have to be followed that this manual can only give in part DMX512 connection Please use xlr xlr signal cable connect the DMX output of the controller with the DMX input of the first device and connect the DMX output of the first device with the DMX input of the second device always connect one output with the input of the next device untill all devices are connected For better sign...

Page 10: ...8 This device has an auto switching power supply work with input voltage range of 100 240V AC 50 60Hz Link up to the maximum 8A Do not exceed this 5 Operation Control board ...

Page 11: ...Dimmer CH02 0 255 DimmerFine 5 brightness increased based on 01CH CH03 0 255 Strobe Manual Dim 0 255 Dimmer D_F 0 255 DimmerFine STO 0 255 Strobe Reset YES NO Recover to manufactory default Temperature C 000 0 255 Current temperature T 080 Protecting temperature Use Up and Down button to select your desired operation press Enter to set all function Notes ...

Page 12: ...on will be deducted slowly Power consumption will be coming to normal when the temperature gets to normal DMX Modes DMX512 Channel table 1CH Channel table Channel Value Rate Control function CH1 Dimmer 0 255 Dimmer brightness from 0 2CH Channel table Channel Value Rate Control function CH1 Dimmer 0 255 Dimmer brightness from 0 CH2 DimmerFi ne 0 255 Brightness micro adjustment 3CH Channel table Cha...

Page 13: ...re replacing the fuse unplug mains lead Procedure Step1 Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and fix it 7 Technical specifications Item Number 113776 Product name IRIDIUM Stage Studio Manual Zoom ...

Page 14: ...Dimming Range 16bit smooth dimming 0 100 DMX Channel 1CH 2CH 3CH Optional Control system STM32 control chip DMX512 signal Display Screen 4 Button LCD Screen IP Rating IP20 Min Distance to Illuminated object 1M Ambient Temp 15 35 Product size 360x270x427mm Weight 5 8kgs Packing 1pc per carton Packing size Inner box 420x330x360mm ...

Reviews: