background image

 

M2M.GEMALTO.COM

Cinterion

®

 Java Terminal

Hardware Interface Description

Version:

01

DocId:

PLS62T-W_HID_v01

Summary of Contents for Cinterion PLS62T-W USB

Page 1: ... M2M GEMALTO COM Cinterion Java Terminal Hardware Interface Description Version 01 DocId PLS62T W_HID_v01 ...

Page 2: ...E CONTEXT OF THE DELIV ERY OF THE PRODUCT THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW Copyright Transmittal reproduction dissemination and or editing of this document as well as utilization of its con tents and communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by patent ...

Page 3: ... 3 3 Terminal Circuit 24 3 4 Operating Modes 25 3 5 RS 232 Interface 26 3 5 1 9 Pole D sub Connector 26 3 6 USB Interface PLS62T W USB 27 3 7 Ethernet Interface PLS62T W LAN 28 3 8 GPIO Interface 29 3 8 1 Serial Interface ASC1 30 3 8 2 I2 C Interface 31 3 8 3 SPI Interface 32 3 8 4 PWM Interface 33 3 8 5 Pulse Counter 33 3 8 6 DSR0 signal 33 3 9 Power Supply 34 3 10 Power Up Power Down Scenarios 3...

Page 4: ...hanics Mounting and Packaging 53 5 1 Mechanical Dimensions 53 5 2 Mounting the Java Terminal 56 5 3 Packaging 57 6 Full Type Approval 58 6 1 Gemalto M2M Reference Setup 58 6 2 Restrictions 59 6 3 CE Conformity 59 6 4 EMC 59 6 5 Compliance with FCC and IC Rules and Regulations 60 7 List of Parts and Accessories 62 8 Appendix A Hardware Watchdog 63 8 1 Reset Conditions 64 8 1 1 Reset stages 64 8 1 2...

Page 5: ...p and Usage 84 9 1 Connection Setup 84 9 2 Connection Usage 86 9 2 1 Access LTE Terminal via Telnet or SSH 86 9 2 2 Access LTE Terminal via FTP 87 9 2 3 Security Notes 88 9 2 4 Configure IP Address 88 9 2 5 Edit APN List 88 9 2 6 Enter SIM Pin 89 9 2 7 Transparent Data Exchange 89 9 2 8 Update LTE Module Firmware 90 9 2 9 Update Ethernet Sub System Software 90 ...

Page 6: ...ew of operating modes 25 Table 12 9 pole D sub female RS 232 26 Table 13 Female 8 pole RJ 45 Ethernet connector 28 Table 14 GPIO connector pin availability and alternate pin functionalities 29 Table 15 Female 6 pole Western plug for power supply ignition power down 34 Table 16 Allowed maximum antenna gain including cable loss 40 Table 17 Absolute maximum ratings 41 Table 18 Operating supply voltag...

Page 7: ...upply ignition reset typical connection 34 Figure 10 SIM interface 38 Figure 11 Status LED 39 Figure 12 Antenna connectors 40 Figure 13 Java Terminal 3D overview 53 Figure 14 Java Terminal mechanical dimensions 54 Figure 15 Java Terminal exploded view 55 Figure 16 Mounting the Java Terminal 56 Figure 17 Reference equipment for approval 58 Figure 18 Hardware watchdog configuration 63 Figure 19 Writ...

Page 8: ...ce Description 0 Document History 8 PLS62T W_HID_v01 2018 06 20 Confidential Prelimenary Page 8 of 91 0 Document History New document Cinterion Java Terminal Hardware Interface Description Version 01 Chapter What is new Initial document setup ...

Page 9: ...faces of the Java Terminal The scope of this document includes interface specifications electrical as well as mechanical characteristics of the Java Terminal It specifies standards pertaining to wireless applications and outlines requirements that must be adhered to for successful product design The Java Terminal is a compact GSM UMTS LTE modem for the transfer of data in GSM UMTS LTE net works In...

Page 10: ...BTS Base Transceiver Station CB Cell Broadcast CODEC Coder Decoder DAI Digital Audio Interface DCE Data Circuit terminating Equipment DSR Data Set Ready DTR Data Terminal Ready EFR Enhanced Full Rate EGSM Enhanced GSM EMC Electromagnetic Compatibility ESD Electrostatic Discharge ETS European Telecommunication Standard FDMA Frequency Division Multiple Access G C F GSM Conformity Forum GSM Global St...

Page 11: ...ed NTC Negative Temperature Coefficient PA Power Amplifier PCB Printed Circuit Board PCM Pulse Code Modulation PCS Personal Communication System PD Power Down PDU Protocol Data Unit PoE Power over Ethernet RED Radio Equipment Directive RF Radio frequency RI Ring Indication RX Receive direction SIM Subscriber Identification Module SMS Short Message Service SW Software TDD Time Division Duplex TDMA ...

Page 12: ...cal and electronic equipment WEEE 2003 108 EC Directive of the European Parliament and of the Council of 8 December 2003 amending directive 2002 96 ec on waste electrical and electronic equipment WEEE Table 4 Standards of North American type approval CFR Title 47 Code of Federal Regulations Part 15 B Part 22 and Part 24 Telecom munications PCS US Equipment Authorization FCC OET Bulletin 65 Edition...

Page 13: ...1 908 1 V11 1 1 IMT cellular networks Harmonized Standard covering the essential requirements of article 3 2 of the Directive 2014 53 EU Part 1 Introduction and common requirements ETSI EN 301 908 2 V11 1 2 IMT cellular networks Harmonized Standard covering the essential requirements of article 3 2 of the Directive 2014 53 EU Part 2 CDMA Direct Spread UTRA FDD User Equipment UE ETSI EN 301 908 13 ...

Page 14: ...06 06 SJ T 11364 2006 Marking for Control of Pollution Caused by Electronic Information Products 2006 06 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the product is...

Page 15: ...cemaker while it is on This personal subgroup always should check the distance to the mobile Switch off the cellular terminal or mobile before boarding an aircraft Make sure it cannot be switched on inadvertently The operation of wireless appliances in an air craft is forbidden to prevent interference with communications systems Failure to observe these instructions may lead to the suspension or d...

Page 16: ...e area with adequate cellular signal strength Some networks do not allow for emergency calls if certain network services or phone features are in use e g lock functions fixed dialing etc You may need to deactivate those features before you can make an emergency call Some networks require a valid SIM card to be properly inserted in the cellular ter minal or mobile If a power supply unit is used to ...

Page 17: ... 1 Cinterion logo 2 Product name 3 Product variant 4 Marking Made in Germany 5 Product ordering number 6 Bar code Code128 7 Product IMEI 8 Date code 9 WEEE symbol see Table 3 10 Chinese RoHS symbol see Table 7 11 CE logo May be replaced for samples with Not for sale see also Section 6 3 12 FCC Declaration of Conformity DoC logo 13 FCC ID for Java module contained in Java Terminal 14 IC ID for Java...

Page 18: ...E2 26dBm 3 4dB for GSM 1800 8 PSK Class E2 26dBm 3 4dB for GSM 1900 8 PSK Output power according to Release 8 Class 3 24dBm 1 3dB for UMTS 800 WCDMA FDD BdXIX Class 3 24dBm 1 3dB for UMTS 850 WCDMA FDD BdV Class 3 24dBm 1 3dB for UMTS 900 WCDMA FDD BdVIII Class 3 24dBm 1 3dB for UMTS AWS WCDMA FDD BdIV Class 3 24dBm 1 3dB for UMTS 1800 WCDMA FDD BdIX Class 3 24dBm 1 3dB for UMTS 1900 WCDMA FDD BdI...

Page 19: ...A Cat 8 HSUPA Cat 6 data rates Compressed mode CM supported according to 3GPP TS25 212 UMTS features 3GPP Release 4 PS data rate 384 kbps DL 384 kbps UL CS data rate 64 kbps DL 64 kbps UL GSM GPRS EDGE features Data transfer GPRS Multislot Class 12 Full PBCCH support Mobile Station Class B Coding Scheme 1 4 EGPRS EHSxT only Multislot Class 12 EDGE E2 power class for 8 PSK Downlink coding schemes C...

Page 20: ...USB 2 0 Slave interface Ethernet PLS62T W LAN 8 pole RJ 45 Ethernet connector Support for Power over Ethernet PoE RS232 RS 232 interface for AT commands and data Supports RTS CTS hardware handshake Supports software XON XOFF flow control Multiplex ability according to GSM 07 10 Multiplexer protocol Baud rates from 1200bps to 230400bps Autobauding supported GPIO connector 20 pin 8 pin and 12 pin he...

Page 21: ...Cinterion Java Terminal Hardware Interface Description 2 1 Key Features at a Glance 21 PLS62T W_HID_v01 2018 06 20 Confidential Prelimenary Page 21 of 91 ...

Page 22: ...le 10 Java Terminal interfaces No Description 1 6 pin Western connector female for power supply ignition power down signal 2 8 pin female RJ 45 Ethernet connector PLS62T W LAN only 3 9 pin female D sub connector RS 232 interface 4 SMA connector female for RF antenna 5 SIM card reader 6 SMA connector female for Rx diversity antenna 7 SMA connector female for GPS antennas for future use currently no...

Page 23: ...of a sample configuration that incorporates a Java Terminal and typical accessories Figure 3 Block diagram Java Terminal Java module RS 232 driver USB SIM card interface Power regulation RF antenna interface LEDs RF antenna interface Host controller Power supply External application Power supply SIM card Antenna IGT_IN RST_IN GPIO driver interface Ethernet interface PLS62T W USB PLS62T W LAN ...

Page 24: ...older SIM card interface CCxxx EMC Batt LED green LED orange LED drivers LED V180 SMA female Antenna interface RFout Western Jack 6 pin Power supply EMC on off EMC power DC DC converter Vreg Line regulator ON EMERG_RST Batt Batt Hardware Watchdog Ethernet RJ45 LED link active Filter 10 100 Ethernet sub system USB GPIO connector 12 pin EMC Driver bidirect GPIO USB B connector EMC USB Electronic SIM...

Page 25: ...onfiguration e g multis lot settings Watchdog active GPRS DATA GPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates GPRS configuration e g used multislot settings and reduction of maximum out put power Watchdog active EGPRS DATA EGPRS data transfer in progress Power consumption depends on network settings e g power control ...

Page 26: ...e Java Terminal are designed for use as a DCE Based on the conventions for DCE DTE con nections it communicates with the customer application DTE using the following signals Port TxD application sends data to TXD0 of the Java Terminal Port RxD application receives data from RXD0 of the Java Terminal Hardware handshake using the RTS0 and CTS0 signals and XON XOFF software flow control are supported...

Page 27: ...all or Unsolicited Result Code URC is received There are different modes of operation which can be set with AT commands Note The DTR0 signal will only be polled once per second from the internal firmware of Java Terminal 3 6 USB Interface PLS62T W USB The Java Terminal PLS62T W USB support a USB 2 0 High Speed 480Mbit s device inter face that is Full Speed 12Mbit s compliant The USB interface can ...

Page 28: ... in Section 3 9 The mains adapter and PoE may be connected in parallel but one of the supplies suffices to operate the LTE Terminal the other may be used a power supply backup Note The maximum cable length between LTE Terminal and the nearest network socket should be 10m and it is recommended that the cable should be shielded Using the Ethernet interface it is also possible to maintain a database ...

Page 29: ...ity of the GPIO connector pins for the Java Terminal Table 14 GPIO connector pin availability and alternate pin functionalities PIN Signal Comment PLS62T W 8 pin connector 1 GPIO6 Configurable via AT command also as PWM2 sig nal 2 GPIO7 Configurable via AT command also as PWM1 sig nal 3 GPIO8 Configurable via AT command also as COUNTER signal 4 GPIO11 Configurable via AT command 5 GPIO12 Configura...

Page 30: ...pplication DTE using the following signals Port TXD application sends data to Java Terminal s TXD1 signal line Port RXD application receives data from the Java Terminal s RXD1 signal line 12 pin connector 1 VCCref Input supply for level adjustment E g connect 5Vout for 5V IO operation 2 GND 3 GPIO17 TXD1 or SPI_MISO Configurable via AT command GPIO or TXD1 RS 232 or SPI_MISO signal GPIO17 TXD1 SPI...

Page 31: ...ressable by a unique 7 bit ad dress and simple master slave relationships exist at all times The Java module operates as master transmitter or as master receiver An external application transmits or receives data only on request of the module To configure and activate the I2C bus use the AT SSPI command Detailed information on the AT SSPI command as well explanations on the protocol and syntax req...

Page 32: ...is done by AT com mand see 1 It is non volatile and becomes active after a module restart For electrical char acteristics please refer to Table 21 To configure and activate the SPI interface use the AT SSPI command Detailed information on the AT SSPI command as well explanations on the SPI modes required for data transmis sion can be found in 1 SPI GPIO and DSR0 functionalities are mutually exclus...

Page 33: ...igured as pulse counter line COUNTER by AT SCFG command see 1 The pulse counter interface is an input line and can be used for example as a clock see also Table 14 GPIO and COUNTER functionalities are mutually ex clusive1 3 8 6 DSR0 signal The DSR0 line available at the RS 232 interface is also routed to the GPIO connector and avail able as a separate pin For electrical characteristics see Section...

Page 34: ...or 1ms Java Terminal reset or switch off The watchdog can be configured to restart the Java Terminal When power fails for 15s the RTC will be reset Figure 9 6 pole Western jack for power supply ignition reset typical connection 1 As an alternative to the power supply via Western jack Power over Ethernet PoE can be employed The PoE feature complies with IEEE 802 3 standards and can be made availabl...

Page 35: ...rted up by plugging an appropriate power supply unit between PLUS and GND of the 6 pole Western jack If switched off i e while in Power Down mode Java Terminal can be started up by activating the IGT_IN signal pin 4 Java Terminal can be started up by activating the RS 232 DTR line as long as RST_IN sig nal pin 3 is not active voltage 2V Java Terminal can be started up by configuring the watchdog a...

Page 36: ... off Normal shutdown To turn off the Java Terminal use the AT SMSO command rather than disconnecting the mains adapter This switch off procedure lets the Java Terminal log off from the network and allows the soft ware to enter a secure state and save data before disconnecting the power supply After AT SMSO has been entered the Java Terminal returns the following result codes SMSO MS OFF OK SHUTDOW...

Page 37: ...rdware watchdog that permanently monitors the terminals hardware and can be configured to react to various hardware states The watchdog may for example be configured to periodically restart the terminal independent of its current operating state Figure 4 shows how the watchdog is integrated into the Java Terminal Please refer to Chapter 8 for details on how to control and configure the hardware wa...

Page 38: ...ccidental removal The SIM can be removed from the card holder by using a flat object such as a screwdriver to carefully press the inserted SIM until it snaps out again All signals of the SIM interface are protected from electrostatic discharge Removing and inserting the SIM card during operation requires the software to be reinitialized Therefore after reinserting the SIM card it is necessary to r...

Page 39: ...e semitransparent cas ing A green LED indicates whether the Java Terminal are ready to operate and reports certain watchdog operations A orange LED indicates the network registration state of the Java Terminal Figure 11 Status LED The orange LED can be configured by using the AT SLED command to either light permanent ly or to flash For details on the AT command please refer to 1 Green LED Power on...

Page 40: ...aximum RF power Additional ESD protection to the antenna connector is provided No DC voltage must be applied to the antenna circuit to protect it from damage Please note that the terminal should be installed and operated with a minimum distance of 20cm between the antenna connected to the terminal and any human bodies Also the trans mitter must not be co located or operating in conjunction with an...

Page 41: ... V GPIO connector pins output current 8 pin and 12 pin connectors if pins specified configured as output pins 0 50mA drawn each pin2 2 Please note that if the VCCref pin is connected to the 5Vout pin no more than 100mA should be drawn by all pins In this case it is no longer allowed to draw a maximum of 50mA for each pin USB interface All electrical characteristics according to USB Implementers Fo...

Page 42: ...ut voltage IGT_IN RST_IN active high 8 30 V Vlow 0 2 V RIN Input resistance of IGT_IN RST_IN 1 M Vhigh Input voltage DTR active high 2 4 25 V Vlow 25 0 8 V RIN Input resistance of DTR 3 5 7 k Table 20 RS 232 interface specifications Parameter Description Conditions Min Typ Max Unit VOUT Transmitter output voltage swing for RXD0 CTS0 DSR0 DCD0 RING0 3k load 5 5 4 V ROUT Transmitter output resis tan...

Page 43: ...te that some GPIO lines can be config ured for functions other than GPIO GPIO6 GPIO7 PWM GPIO8 Pulse Counter WD_RETRIG VCCref I Vimax 5 5V Vimin 1 8V Input current has to at least match the positive output current required by all configured and used GPIO lines For level adjustment E g connect 5Vout for 5V IO operation Must be connected to 1 8 5 5V if employing signals from GPIO con nector GND GPIO...

Page 44: ...age for details on how to setup and use the Java Terminal with Ethernet interface 8 pin 12 pin connec tors for GPIO Power I2 C and ASC1 SPI I2CDAT IO Open drain IO VOLmin 0 3V at I 3mA VOHmax VCCref Rpullup 2 2kOhm VILmax 0 35V VIHmin 1 3V VIHmax VCCref According to the I2 C Bus Specification Version 2 1 for the fast mode a rise time of max 300ns is per mitted There is also a maximum VOL 0 4V at 3...

Page 45: ...time 3 min Power Down mode 8V 21 mA 30V 10 57V Average GSM supply current average time 3 min 3 IDLE mode GSM GPRS 850 900MHz 1800 1900MHz 8V 40 mA 30V 16 57V GPRS DATA mode 1 Tx 4 Rx 850 900MHz 8V 175 mA 30V 50 57V GPRS DATA mode 1 Tx 4 Rx 1800 1900MHz 8V 140 mA 30V 38 57V GPRS DATA mode 4 Tx 1 Rx 850 900MHz 8V 245 mA 30V 100 57V GPRS DATA mode 4 Tx 1 Rx 1800 1900MHz 8V 190 mA 30V 56 57V EDGE DATA...

Page 46: ... 200 57V Average UMTS supply current average time 3 min IDLE mode 8V 79 mA 30V 12 57V UMTS DATA Band I 23dBm 8V 410 mA 30V 115 57V UMTS DATA Band II 23dBm 8V 450 mA 30V 125 57V UMTS DATA Band V VI 23dBm 8V 415 mA 30V 115 57V UMTS DATA Band VIII 23dBm 8V 410 mA 30V 115 57V HSPA DATA Band I 23dBm 8V 415 mA 30V 115 57V HSPA DATA Band II 23dBm 8V 450 mA 30V 125 57V HSPA DATA Band V VI 23dBm 8V 415 mA ...

Page 47: ...in IDLE 8V mA 30V 57V LTE DATA Band 1 23dBm 8V mA 30V 57V LTE DATA Band 2 23dBm 8V mA 30V 57V LTE DATA Band 3 23dBm 8V mA 30V 57V LTE DATA Band 4 23dBm 8V mA 30V 57V LTE DATA Band 5 23dBm 8V mA 30V 57V LTE DATA Band 8 23dBm 8V mA 30V 57V LTE DATA Band 12 23dBm 8V mA 30V 57V LTE DATA Band 13 23dBm 8V mA 30V 57V Table 22 Power supply specifications Para meter Description Conditions Unit PLS62T W USB...

Page 48: ... mA 30V 57V LTE DATA Band 20 23dBm 8V mA 30V 57V LTE DATA Band 28 23dBm 8V mA 30V 57V 1 Lowest voltage minimum peak incl all ripple and drops 7 6V including voltage drop ripple and spikes measured at western jack 6 pole pins 2 Typical values measured with antenna impedance 50 Ohm return loss 20dB 3 BGS5T USB does not support EDGE Table 22 Power supply specifications Para meter Description Conditio...

Page 49: ... Java module 30 85 C Extended operation1 2 2 Extended operation allows normal mode speech calls or data transmission for limited time until au tomatic thermal shutdown takes effect Within the extended temperature range outside the normal operating temperature range the specified electrical characteristics may be in or decreased 40 to 30 85 to 90 C Automatic thermal shutdown1 3 3 Due to temperature...

Page 50: ...not every module variant supports all bands Receiver Input Sensitivity ARP UMTS 800 850 Band VI V 104 7 106 7 110 dBm UMTS 900 Band VIII 103 7 110 dBm UMTS 1900 Band II 104 7 109 dBm UMTS 2100 Band I 106 7 110 dBm RF Power ARP with 50Ohm Load Board temperature 85 C UMTS 800 850 Band VI V 21 24 25 dBm UMTS 900 Band VIII 21 24 25 dBm UMTS 1900 Band II 21 24 25 dBm UMTS 2100 Band I 21 24 25 dBm GPRS ...

Page 51: ... EDGE 1 TX GSM 850 E GSM 900 27 dBm GSM 1800 GSM 1900 26 dBm GPRS 2 TX GSM 850 E GSM 900 30 dBm GSM 1800 GSM 1900 27 28 3 dBm EDGE 2 TX GSM 850 E GSM 900 24 dBm GSM 1800 GSM 1900 23 dBm GPRS 3 TX GSM 850 E GSM 900 28 2 27 7 dBm GSM 1800 GSM 1900 25 2 27 4 dBm EDGE 3 TX GSM 850 E GSM 900 22 2 dBm GSM 1800 GSM 1900 21 2 dBm GPRS 4 TX GSM 850 E GSM 900 27 25 4 dBm GSM 1800 GSM 1900 24 25 2 dBm EDGE 4...

Page 52: ... relative Low High Condens 10 90 at 30 C 90 100 at 30 C ETS 300 019 2 1 T1 2 IEC 60068 2 56 Cb ETS 300 019 2 1 T1 2 IEC 60068 2 30 Db Air pressure Low High 70 106 kPa IEC TR 60271 3 1 1K4 IEC TR 60271 3 1 1K4 Movement of surrounding air 1 0 m s IEC TR 60271 3 1 1K4 Water rain dripping icing and frosting Not allowed Radiation Solar Heat 1120 600 W m2 ETS 300 019 2 1 T1 2 IEC 60068 2 2 Bb ETS 300 01...

Page 53: ...the mechanical dimensions of the board For further details see Figure 14 and Figure 15 To allow for an easier mechanical implementation into an external application 3D STP data for the Java Terminals is attached to this PDF Please open the Attachments navigation panel to view and save this in formation Figure 13 Java Terminal 3D overview Length 113 5mm including fixtures for cable straps Width 75m...

Page 54: ...Cinterion Java Terminal Hardware Interface Description 5 1 Mechanical Dimensions 57 PLS62T W_HID_v01 2018 06 20 Confidential Prelimenary Page 54 of 91 Figure 14 Java Terminal mechanical dimensions ...

Page 55: ...Cinterion Java Terminal Hardware Interface Description 5 1 Mechanical Dimensions 57 PLS62T W_HID_v01 2018 06 20 Confidential Prelimenary Page 55 of 91 Figure 15 Java Terminal exploded view ...

Page 56: ...0 format A catch at the terminal s bottom side will have to be removed to slide mul tiple terminals onto a single rail Using a BOPLA TSH 35 2 universal DIN rail holder the Java Terminal can be fitted onto another special type of DIN rail made according to DIN EN 60715 Top hat section 35mm e g Wago 210 113 steel carrier rail The following figure shows the various possibilities provided to mount the...

Page 57: ...a Terminal Hardware Interface Description 5 3 Packaging 57 PLS62T W_HID_v01 2018 06 20 Confidential Prelimenary Page 57 of 91 5 3 Packaging Java Terminal come in terminal boxes Terminal box size 191mm x 143mm x 44mm ...

Page 58: ...M Reference Setup The Gemalto M2M reference setup submitted to type approve Java Terminal consists of the following components Java Terminal with approved Java module PC as MMI Power Supply Figure 17 Reference equipment for approval For ordering information please refer to Chapter 7 PC Power supply SIM RS 232 USB LAN Java Terminal Antenna or 50Ohm cable to the system simulator ARP ...

Page 59: ...tions that comply with the approved Java Terminal configuration Extra approval must be obtained for applications using other accessories than those included in the approved Java Terminal configuration power supply MMI implementation supported by AT commands 6 3 CE Conformity The Java Terminal meet the requirements of the EU directives listed below RED Directive 2014 53 EU The Java Terminal are mar...

Page 60: ...and found to comply with the limits for a Class B dig ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reason able protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio co...

Page 61: ...onnement EN Radio frequency RF Exposure Information The radiated output power of the Wireless Device is below the Industry Canada IC radio fre quency exposure limits The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized This device has also been evaluated and shown compliant with the IC RF Exposure limits un der mobile ex...

Page 62: ...il holder BOPLA TSH 35 2 BOPLA Ordering number 20035000 BOPLA Gehäuse Systeme GmbH Borsigstr 17 25 D 32257 Bünde Phone 49 0 5223 969 0 Fax 49 0 5223 969 100 Email info bopla de Web http www bopla de Antenna SMARTEQ MiniMAG Dualband 0dBd 2 6m RG174 SMA m KÖBEL Mobile Communication Ordering number 1140 26 with crimped SMA connector KÖBEL Mobile Communication Sesamstrasse 12 D 24632 Lentföhrden RS 23...

Page 63: ...R0 ADC1_IN us age trigger delay and firmware infos can be specified by means of a special write read pro tocol handled by the watchdog s I2 C interface For details on how to configure the watchdog via I2 C interface see Section 8 4 The below Figure 18 illustrates the various ways the watchdog may be accessed and config ured Figure 18 Hardware watchdog configuration Note Unless the complete configu...

Page 64: ...l observe the activities on the UART and GPIO interfaces as well as the Java module status depending on timeout parameter settings and perform fre quent resets if it is configured to do so 8 1 1 Reset stages Basically there are up to two escalation stages during a module reset First stage regular fast shutdown The watchdog shuts down the module via an internal fast shutdown signal The fast shutdow...

Page 65: ...an be prevented once for a certain amount of time This timeout TRG_DEL can be configured via the I2 C interface It can be particularly useful when a software update is performed Using the TRG_DEL timeout will prevent the watchdog from resetting the module during the running TRG_DEL timeout so that the update can be per formed safely An upcoming reset event will be shifted and catch up after the TR...

Page 66: ...be sent to the watchdog See Section 8 3 1 for the watchdog s configuration command specification Once completed the terminal program should be changed to higher baud rates again to enable proper communication with the module Note that the Java module has to be up and running for this type of configuration Please note that a qualified set of configuration commands can also be configured via I2 C in...

Page 67: ...tion using any of the following commands disables the watchdog Repetitive module reset UART reset GPIO reset Restart delay and Always on With these commands the new configuration setting becomes effective only after the hardware watchdog is enabled again 8 3 1 1 Watchdog On Off This command is used to enable or disable the watchdog function When disabled all timers are stopped and the watchdog doe...

Page 68: ...chdog is enabled The param eter sets the RST_REP timeout value If the watchdog is enabled an unconditional module re set every RST_REP milliseconds is performed Changing this configuration disables the watchdog The feature becomes active if the watch dog is enabled again and after the MIN_START_TIME has passed For normal operation this value should be set to a value greater than 30 minutes some us...

Page 69: ...odule output within the specified time period Otherwise the watchdog will reset the module If enabled each GPIO8 toggling resets the timer to its configured value Note that for this feature to work GPIO8 has to be available and enabled and its direction must be set to output Please refer to Section 8 3 1 11 Section 8 4 and Section 8 5 for details on how to configure GPIO directions If configured a...

Page 70: ...ll have to send keep alive signals to the I2 C bus ad dress 0x09 within the specified time period If the keep alive signals are not regularly received at this address the watchdog will reset the Ethernet sub system Changing this configuration disables the watchdog The feature becomes active if the watch dog is enabled again and after the MIN_START_TIME has passed For normal operation this value sh...

Page 71: ... MIN_START_TIME has expired Changing this configuration disables the watchdog The feature becomes active if the watch dog is enabled again It is strongly recommended to set this value to a time period of more than 30 minutes for normal operation During development it may be set to values of less than 30 minutes but should al ways be greater than the time the module needs for a complete start up in...

Page 72: ...emperature events In case of over under tempera ture shut down it can be expected that the temperature does not change significantly within a minute During development the timeout may be set to a period of less than 1 minute 8 3 1 9 Load Default Values This command loads the default configuration values This disables the watchdog If the watch dog is enabled the reset timeout values the MIN_START_T...

Page 73: ...ss This may become nec essary to avoid address conflicts on the I2 C bus if used in an environment where the default I2 C address 0x6A is already in use by other slave devices connected to the Java Terminal Changing the I2 C address takes effect immediately and has no impact on the watchdog s en abled disabled state Command I2C_ADDR Parameter address Type Number Range 1 127 Default 106 0x6A Non vo...

Page 74: ... Special care must be taken that no outputs are cross connected during the switching phase Configuring a Java Terminal output the level shifter output should be set first followed by the module output configuration Configuring an input the module input should be set first followed by the level shifter input Please refer to Section 8 5 for more information on how to configure GPIO directions Please...

Page 75: ...ine If configured as digital output the signal is connected to the Java module s DSR0 SPI_CLK line that can be configured to be either DSR0 or SPI_CLK SPI_CLK not available for BGS5T USB Note If configuring the ADC1_IN DSR0 SPI_CLK line please take great care to be in accor dance with the Java module s current configuration of the ADC1_IN and DSR0 SPI_CLK sig nals Command ADC_DSR0 Parameter input ...

Page 76: ...he I2 C interface please allow for a guard time of at least 500ms between two I2 C commands The I2 C interface implements the write and the read protocol as described in Section 8 4 1 The 7 bit device address is 0x6A binary 1101010 The default address can be changed by con figuration command see Section 8 3 1 10 8 4 1 I2 C Interface Command Specification 8 4 1 1 WRITE Command Syntax Example settin...

Page 77: ...c register a write command with RAR as the address byte and the register to be read as the data byte has to be issued first The next read will then return the value at this address Note that there are only a few registers that can be read see register table Table 27 When the RAR is written with a non read ad dress the RAR is set to the SR and the status code ILLEGAL_ARGUMENT is saved Note also tha...

Page 78: ...ger delay time is specified the watchdog is prevented from resetting the module for the given time TDR No 0x00 Set time in min utes 1 255 Minutes 0 Disable 0xFD R Hardware watchdog s firmware version VER 0x00 0x99 MAJ MIN 4 MSB MAJ 4 LSB MIN MAJ Mainrelease number e g 1 x MIN Sub release number e g x 0 as in version v1 0 0xFF W Read address register RAR RAR No 0x00 0x00 0xFF Only valid addresses c...

Page 79: ...knowledgments D4 indicates the slave address write mode 14 specifies the address register GPIO12 and 01 sets the data byte i e line is output Note The data byte value is only written if valid i e if in the specified range After a WRITE command the status code of the operation is saved to the status register SR and a subsequent READ command from the status register will then return the latest statu...

Page 80: ... this command Note The data byte value is only written if valid i e if in the specified range After a WRITE command the status code of the operation in this case i e where the register address is the RAR the content of the register given as data byte is saved to the status register SR and a subsequent READ command from the status reg ister will then return the register value i e the hardware watch...

Page 81: ...GPIO directions by means of the watchdog As described in Section 8 3 Section 8 4 and shown in Figure 18 there are various ways to con figure the watchdog and therefore the level shifter s GPIO directions A qualified configuration including GPIO directions can be done using the watchdog s I2 C interface For details see Section 8 5 1 This is the recommended method to set the level shifter s GPIO dir...

Page 82: ...res see also 1 Note When using a Java MIDlet to set GPIO directions using the I2 C interface please allow for a guard time of at least 500ms between two I2 C commands GPIO connector Java module Level shifter GPIO7 GPIO7 Set level shifter to OUTPUT using AT SSPI and a specific read write protocol over I2 C interface Level shifter GPIO7 GPIO7 Set GPIO7 at Java module to OUTPUT with GPIO command AT S...

Page 83: ...tting GPIO direction to INPUT via TXD0 line at 1200bps For more information on the AT commands mentioned in the above figures see also 1 GPIO connector Java module Level shifter GPIO7 GPIO7 Set level shifter to OUTPUT with watchdog command WD GPIO_DIR 527 14 Level shifter GPIO7 GPIO7 Set GPIO7 at Java module to OUTPUT with GPIO command AT SCPIN 1 6 1 Now IO state can be set with AT SSIO 6 0 Steps ...

Page 84: ...n Chapter 7 A green LED indicates the connected power supply and the LTE Terminal including LTE module is started up As an alternative it is possible to employ PoE see Section 3 7 3 Plug the Ethernet cable between an external application such as a PC and the LTE Termi nal LTE Terminal as DHCP server is able to provide a valid IP address to the PC 4 Insert the SIM card If required to for instance c...

Page 85: ...no root login password is configured In case a root login password exists access to the embedded Linux system is only possible via SSH using e g PuTTY for Windows 6 Having set up the Ethernet connection the link can now be used to exchange data as well as for administration purposes see Section 9 2 for details A Telnet or SSH connection can be terminated by simply closing the PC s command shell ...

Page 86: ...LTE Terminal can be accessed from a PC via Telnet or SSH for administrative purposes and there are two types of connection Calling Telnet or SSH as described above in Section 9 1 connects to the LTE Terminal s embedded Linux system The Linux shell provides access to files containing the network con figuration see Section 9 2 4 as well as the wireless APN configuration see Section 9 2 5 Calling Tel...

Page 87: ...d directory for FTP services The FTP server s root directory in the embedded Linux file system is tmp fw the default user name to access FTP services is fw and default password is also fw If accessing the LTE Terminal s FTP server from a Windows PC the FTP client should support passive FTP PASV The default Windows FTP client does not support passive FTP However the FTP cli ent from WinSCP for inst...

Page 88: ...al directory For more information on FTP access see Section 9 2 2 Edit the file and adapt the line option ipaddr 192 168 1 1 to for instance option ipaddr 192 168 2 1 Commit the new IP address by entering etc init d network restart After the restart the system can be reached via the new IP address 9 2 5 Edit APN List Using the APN list LTE Terminal determines the applicable APN for the inserted SI...

Page 89: ...ave the SIM pin to the flash file system and activate the pin it through a reboot root OpenWrt etc uci commit root OpenWrt etc reboot To read the currently used SIM pin please enter the command root OpenWrt etc uci show network 3gwan pincode 9 2 7 Transparent Data Exchange To transparently exchange data please complete the following steps 1 Set up an Ethernet connection as described in Section 9 1...

Page 90: ...Telnet or SSH as described in Section 9 2 1 Call the firmware update shell script etc gmup sh After a successful update the LTE ter minal restarts automatically 9 2 9 Update Ethernet Sub System Software To update the software of the LTE Terminal s Ethernet sub system please complete the fol lowing steps Connect to the LTE Terminal using FTP as described in Section 9 2 2 Transfer the software downl...

Page 91: ...privacy protection eHealthcare and eGovernment efficiency convenient ticketing and dependable machine to machine M2M applications Gemalto develops secure embedded software and secure products which we design and personalize Our platforms and services manage these secure products the confidential data they contain and the trusted end user services they enable Our innovations enable our clients to o...

Reviews: