2.9 AT+CMEE
ENS22-E_ATC_V01.000
19/02/11
Page 35 of 189
2.9
AT+CMEE Error Message Format
controls the format of error result codes that indicates errors related to
Cinterion
®
ENS22-E
functionality. Format can be selected between plain "ERROR" output, error numbers or verbose "+CME
" and "+CMS ERROR:
Possible error result codes are listed in Table
General "CME ERROR" Codes (3GPP TS 27.007)
, Table
EPS related "CME ERROR" Codes (3GPP TS 27.007)
Syntax
Parameter Description
0
(&F)(D)
Disable result code, i.e. only "ERROR" will be displayed.
1
Enable error result code with numeric values.
2
Enable error result code with verbose (string) values.
Example
To obtain enhanced error messages it is recommended to choose
Test Command
AT+CMEE=?
Response(s)
+CMEE:
(list of supported
OK
Read Command
AT+CMEE?
Response(s)
+CMEE:
OK
Write Command
AT+CMEE=
Response(s)
OK
ERROR
+CME ERROR:
PIN Last
Reference(s)
-
-
3GPP TS 27.007
, 3GPP TS
<errMode>
(num)(&V)(&W)
AT+CMEE=2
OK