Cinterion
®
ENS22-E AT Command Set
8.4 AT+CGDCONT
ENS22-E_ATC_V01.000
19/02/11
Page 133 of 189
8.4
AT+CGDCONT Define PDP Context
The
write command specifies the parameters for a PDP context identified by the context identifier
. The number of contexts that may be in a defined state at the same time is given by the range indicated
in the test command response. A special form of the write command (
) causes the values
for context
to become undefined. The initial PDP context (+CGDCONT: 0,"IPV4V6",,0,0,0) is supported,
and
=0 resets context number 0 to its particular default settings.
The
read command returns the current settings for each defined PDP context.
The
test command returns supported values as a compound value.
Syntax
Parameter Description
PDP Context Identifier
Parameter specifies a particular PDP context definition. The parameter is used in other PDP context-related
commands.
The
value cannot be set to 7 when Bearer Independent Protocol (BIP) is enabled.
Only the context definition with
=0 is stored in non-volatile (NV) memory.
0
(D)
...10
Test Command
AT+CGDCONT=?
Response(s)
+CGDCONT:
(range of supported
s),
s), (list of supported
s), (list of supported
OK
ERROR
+CME ERROR:
<err>
Read Command
AT+CGDCONT?
Response(s)
+CGDCONT:
,
,
[
+CGDCONT:
...]
OK
ERROR
+CME ERROR:
<err>
Write Command
AT+CGDCONT=
[,
[,
]]]]]
Response(s)
OK
ERROR
+CME ERROR:
<err>
PIN Last
Reference(s)
-
-
3GPP TS 27.007
<cid>
(num)(NV)