Rev. 00 03/22
OptiFeed BigBag (FPS16)
Fault clearance
•
47
Software error diagnostics
General information
The correct function of the device is constantly monitored. If the
equipment software determines a fault, an error message is indicated with
a help code. Following is monitored:
– Power supply
– Pneumatic system
– Communication system
Help codes
The error diagnosis codes (help codes) are shown on the display.
The help codes are stored in an error list in the order of their appearance.
Each error in the list must be individually acknowledged with the
key.
The errors are displayed in the order of their appearance.
Here is a list of all possible help codes for this powder pump:
Code
Description
Criteria
Remedy
Power supply:
H20
Voltage supply error
Mainboard
Mainboard defective
Contact Gema Service
H21
Supply undervoltage
Power pack defective or
overloaded
Contact Gema Service
EEPROM (equipment memory):
H24
EEPROM content invalid
EEPROM error
Contact Gema Service
H25
Timeout during EEPROM
writing
EEPROM error
Contact Gema Service
H26
Values not correctly
stored in EEPROM during
switching off
EEPROM error
Contact Gema Service
H27
EEPROM verification
erroneous
EEPROM error
Contact Gema Service
CAN bus:
H40
Permanent CAN bus error
The CAN controller changes into
BUS OFF condition.
No power supply or cable is not
connected.
Connect the cable,
otherwise contact Gema
service
H41
High error rate when
transmitting/receiving
The CAN controller changes into
ERROR_PASSIVE condition
Contact Gema Service
Summary of Contents for FPS16
Page 6: ......
Page 34: ...Rev 00 03 22 34 Start up OptiFeed BigBag FPS16 ...
Page 38: ...Rev 00 03 22 38 Operation OptiFeed BigBag FPS16 ...
Page 52: ...Rev 00 03 22 52 Fault clearance OptiFeed BigBag FPS16 ...
Page 54: ...Rev 00 03 22 54 Disposal OptiFeed BigBag FPS16 ...
Page 60: ......
Page 62: ...Rev 00 ...