Specification
RTS-500
Infrared Sensor Exit
The product is warranted against defects in material and
workmanship while used in normal service for a period of 1
year from the date of sale to the original customer. The GEM
policy is one of continual development and improvement;
therefore GEM reserves the right to change specifications
without notice.
Warranty
Statement
Features
Dimensions
RTS-500
RTS-500N
European Sized Face Plate
Infrared,
suitable
for
any environment
10 cm Proximity Range
Compatible
with
Access Control Units
Emergency Exit Button
The
of connection, and
the diagrams below, illustrate two recommended ways of
connection.
In Fig A,
relay output connects to 'Request-to-exit input
contact' on the control device; therefore it is better to adjust
the RTS relay timer to the shortest time.
In Fig. B, the release of
was controlled by
RTS relay output directly; therefore, the relay time of RTS is
the release time of
.
and access
control package has many different ways
RTS-500 Infrared Sensor Exit Device
RTS
Locking Device
Locking Device
Operating Voltage: 12VDC
Current Draw: Holding 50mA, Pull
in 60mA/12VDC
Case Dimension: 88(L)x88(W)mm
Sensor Range: Up to 10 cm (18% gray reflection)
Relay Rating: 3A/125VAC/30VDC
Operating Temperature: -20~+70ºC
A m b i e n t H u m i d i t y : 5 ~ 9 5 % r e l a t i v e h u m i d i t y ( n o n -
condensing)
Relay Timer: 0.5, 5,10,20 Seconds
Relay Timer:
0.5 seconds
5 seconds
10 seconds
20 seconds
86m
m
86m
m
Application
Fig. A
Control Device
Request-to-exit
input contact
Relay output
control
Locking Device
NC
COM
NO
+
Fig. B
NC
COM
NO
+
12VDC
12VDC
Locking Device
(Fail-Safe)
No. 13, Zhongxing Rd., Tucheng Dist., New Taipei
City 236,Taiwan (R.O.C.)
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876
E-Mail: [email protected]