8 Technical data
8.1 Mechanical data
Protection class:
IP 65
Measured data:
Device type
Number of
switch points
Metering
length
Distance of
reed contacts
GEMÜ 1270000Z2501
55
230 mm
4,25 mm
GEMÜ 1270000Z2503
100
230 mm
2,30 mm
GEMÜ 1271000Z1001
35
118 mm
3,50 mm
GEMÜ 1271000Z2501
43
147 mm
2,30 mm
GEMÜ 1272000Z2501
55
210 mm
4,25 mm
GEMÜ 1272000Z2503
100
210 mm
2,30 mm
GEMÜ 1273000Z1001
35
118 mm
3,50 mm
GEMÜ 1273000Z2501
43
125 mm
3,50 mm
8.2 Electrical data
Supply voltage:
GEMÜ 1270, 1271:
max. 24 V DC
GEMÜ 1272, 1273:
U
min
11 V DC + 0.02 A x load resistor (Ω)
U
max
40 V DC
For values see diagram
max. permissible voltage 40 V
Load resistor max. 1400 Ω
Max. power consumption:
V x 20 mA
Output current:
4 - 20 mA
Detection of measured val-
ues:
Series of reed contacts connected to a chain of resistors 0 – 10 kΩ
Electrical connection
type:
Plug, design B
www.gemu-group.com
10 / 20
GEMÜ 127x
8 Technical data