___________________________________________________________________________________________________________________________
Rev.1
Date 17.06.2013
Page 10 / 14
THE REAR PANEL
a
VOLTAGE SWITCH
Make sure that the voltage switch setting reflects the correct local power line voltage. For line
voltages from 100V to 120V, set the switch to 115V. The 230V position is good for all line
voltages from 200-240Volts.
b
MAINS INPUT / AC FUSES HOLDER
The mains AC connector is a standard IEC-type 3 pin connector with a AC fuses (2 pieces)
holder. The ground of this AC connector is permanently internally connected to the chassis of
the
Sculptor
for safety. It is important to change the fuse before changing the supply voltage:
630mA (slo-blo; 5x20mm) for 230V~50 Hz
1,25A (slo-blo; 5x20mm) for 115V~60 Hz
c
INPUT
Balanced input XLR wired according to the AES standard : Pin 1 = shield, Pin 2 = hot (+), Pin
3= cold (-). In order to avoid hum, it is recommended to use the device only in balanced
connections.
d
OUTPUT
Balanced output XLR wired according to the AES standard : Pin 1 = shield, Pin 2 = hot (+),
Pin 3= cold (-). In order to avoid hum, it is recommended to use the device only in balanced
connections.
e
INSERT SEND
Balanced insert
TRS ¼”
send wired according to the AES standard : Slave = shield, Tip = hot
(+), Ring = cold (-). In order to avoid hum, it is recommended to use the device only in
balanced connections.