the product properly, as it knows the time interval between an impulse and the next one.
This function sets the MAXIMUM time between an impulse and the next one. Once this time is exceeded,
the pump will restart dosing, as if it is the first time it receives an impulse.
“Timeout” default value is 120 seconds.
To change the “Timeout” time between the minimum (1 sec.) and the maximum (999 sec.), operate as
follows:
- Use “
UP
” key to increase by one unit the digit where the cursor “_” is blinking.
- Press “
RIGHT
” key for next digit.
- Press “
P
” key to save the entered data and “
ESC
” to exit to main menu or only press “
ESC
” to exit
without saving.
Impulses Timeout is not operating in “Divide” working mode and in all working modes where the calculation
result is a division.
Impulse supplied to the pump
At the beginning the pump doesn’t know how much time passes
between the first and the next impulse.
Therefore it will dose the product in the shortest time possible. “Timeout” function forces the pump to
work in this mode, if the time set is exceeded.
Then, the pump will have a time reference and will distribute dosing in the next impulses in an optimised
way.
11.7 Initial Setup (unit; delay)
Unit of measure selection.
Selection of the unit of measure. It is possible to choose the unit of measure
(either litres or gallons) shown on display. Choose the unit of measure
according to your requirements.
- Use “
UP
” key to change unit of measure.
- Press “
P
” key to save the entered data and “
ESC
” to exit to main menu or
only press “
ESC
” to exit without saving.
SET ( 05 )
timeout
timeout
020 sec
Tasto
SET ( 06 )
unit
UNIT
litre
unit
usgal
SET ( 07)
delay
power on
01 min
Tasto
Tasto
Tasto
Tasto
Key
Key
Key