OPERATION
Releasing Attachment Using Hydraulic Pressure Signal
Bypass
Only use this removal procedure on attachments or
in situations where it is not possible to fully crowd
the quick coupler.
AVOID SERIOUS INJURY OR DEATH
•
Keep bystanders away when engaging and
releasing attachment.
•
Keep attachment close to ground during
engaging or releasing attachment. Attachment
can fall off without warning if not fully engaged
and locked causing death or serious injury.
Park the machine on flat, level surface.
Figure 28
Lower quick coupler and attachment to the ground
Figure 29
Press the POWER button (1)
. An alarm will
sound and button will illuminate.
Press UNLOCK button (2)
within six seconds
of pressing power button. Alarm will change tone and
unlock button will illuminate.
NOTE: Unlock button (2) [Figure 29] must be pressed
within six seconds of pressing power button
or system will not operate (alarm and lights
will shut-off). If this occurs, restart the
procedure by pressing the power button.
Press and hold the hydraulic pressure signal bypass
button (3)
for six seconds. All four buttons on
the control box will illuminate and the alarm tone will
become constant.
Figure 30
Wait for coupler locking clasp and sliding hook to open.
After coupler locking clasp and sliding hook are open, roll
the quick coupler away from attachment pins
.
IMPORTANT
WARNING
1
2
3
Summary of Contents for QC100 H1
Page 1: ...GEITH QUICK COUPLER MANUAL www geith com PT No 823000088876 2 Released 05 2016 ...
Page 2: ......
Page 4: ......
Page 6: ...www geith com ...
Page 10: ...1 4 www geith com INTRODUCTION ...
Page 20: ...2 10 www geith com SAFETY ...
Page 48: ...4 10 www geith com MAINTENANCE ...
Page 49: ...www geith com 5 1 SPECIFICATION SPECIFICATIONS Four Port Control Box ...
Page 52: ...5 4 www geith com SPECIFICATION ...
Page 57: ......