GM1093 - Watchdog 1000 Series User Manual 

Revision Date: 02/13/2015 

 

EMC Verification 

This Class A device complies with part 15 of the FCC Rules.  Operation is subject to the following 
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation. 
 
This Class A digital apparatus complies with Canadian ICES-003.  
 
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. 
 
Warning: Changes or modifications to this unit not expressly approved by the party responsible for 
compliance could void the user’s authority to operate this equipment.  

 

Summary of Contents for Watchdog 1000 Series

Page 1: ...Geist 1821 Yolande Ave Lincoln NE 68521 800 432 3219 402 474 3400 F 402 474 4369 www geistglobal com Instruction Manual Environmental Monitoring Unit Watchdog 1000 Series Firmware Version 3...

Page 2: ...ration 17 Network Configuration 17 Time and Date 18 E Mail 18 SNMP 19 Accounts and Passwords 20 Telnet 20 Camera Configuration 21 Admin Information 21 Alarms 22 Alarm Notifications 22 Alarm Types 22 T...

Page 3: ...vailable The Watchdog 1000 have a built in temperature sensor The Watchdog 1000 has 16 expansion ports for the connection of external sensors and 3 I O ports for optional remoter sensors Watchdog 1000...

Page 4: ...nterference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 Cet apparei...

Page 5: ...nstall the Watchdog 1000 Environmental Monitoring Unit such that the amount of airflow required for safe operation of equipment is not compromised Mount the Watchdog 1000 Environmental Monitoring Unit...

Page 6: ...he IP address has been reset Note Pressing the reset button will restore the default IP address and will also clear all password settings The Configuration page allows you to assign the network proper...

Page 7: ...ect Network under Internet Network Select Ethernet from the list on the left side of the window and enter these settings on the right side of the window Configure Manually IP Address 192 168 123 1 Sub...

Page 8: ...torical views of the unit s data Real time readings are provided for all sensor data next to historical graphs Optional cameras may be added and their live snapshots are shown on this page On Watchdog...

Page 9: ...ged into the data file at a rate of one point per minute Please note that although data is logged once per minute all sensor data used in the real time display and alarm functions is read at least onc...

Page 10: ...ll as change the default temperature unit of measure for sensors The display page also allows the user to select between the default and classic web page layouts The default interface displays a verti...

Page 11: ...sh alarm conditions for each sensor reading Alarm conditions can be established with either high or low trip thresholds The alarms are displayed in different sections based on the device the alarm is...

Page 12: ...as five sub tabs Network Monitoring Diagnostics Event Log and Admin See Unit Configuration page 17 for details Configuration Network Tab The user can enter and update the network settings on the Netwo...

Page 13: ...Date 02 13 2015 Configuration Monitoring Tab The user can enter and update the email alert SNMP and camera settings on the Monitoring tab of the Configuration page See Unit Configuration section page...

Page 14: ...og 1000 Series User Manual 14 Revision Date 02 13 2015 Configuration Diagnostics Tab The user can update the Syslog settings on the Diagnostics tab of the Configuration page Figure 10 Configuration Di...

Page 15: ...es User Manual 15 Revision Date 02 13 2015 Configuration Event Log Tab The user can view the Event Log and update the Memory Syslog settings on the Event Log tab of the Configuration page Figure 11 Co...

Page 16: ...13 2015 Configuration Admin Tab The user can set the system clock and administrative information on this tab Additionally the user can set administrator and account passwords See Unit Configuration pa...

Page 17: ...k Static IP Address Net Mask Gateway When not using a dynamic address enter static network configuration information here Telnet Service Enable or disable the built in Telnet server See Telnet page 20...

Page 18: ...e server is contacted or the system clock is manually set all log time stamps will present time as the number of seconds since the unit was powered up and graphs will not be shown Figure 14 Time Setti...

Page 19: ...odically send a full status report to all To e mail addresses selected for the report The report includes current unit data from all attached sensors as well as alarm states Reporting frequency option...

Page 20: ...o enable the View Only account Note The account names root and admin are disabled for security reasons and cannot be re enabled Warning Record your passwords To reset lost passwords follow the instruc...

Page 21: ...tion page The unit will present a linked snapshot from each camera on the Sensors page Figure 20 Configuration and Supported Models Note Each camera must be set to allow anonymous access to enable thi...

Page 22: ...ensor already in the Tripped or Unplugged state goes back into its normal range Unplugged Occurs when a sensor with an alarm set loses contact with the main unit due to the sensor being physically unp...

Page 23: ...steady state conditions for several hours before setting alarm thresholds By allowing the sensors to operate for several hours the user can better understand what the normal variations are thereby al...

Page 24: ...t the factory and the values reported by this sensor are accurate However due to low airflow and normal board heating the temperature sensor may read a few degrees higher than any external sensors tha...

Page 25: ...15 Figure 25 Door Sensor Wiring Example Additional Optional I O Sensors RWS Water Sensor RDPS Door Sensor SA 1 Smoke Alarm RCP 2 125 V City Power Monitor WSK 10 10 Water Sensing Cable Kit WSK 40 40 Wa...

Page 26: ...e contact Customer Service for installation options Connecting Remote Sensors Plug and play remote sensors may be attached to the unit at any time via the RJ 12 connectors on the face of the unit A sp...

Page 27: ...its Geist RSC software offers Convenient single window monitoring of multiple units via simple web based interface Streamlined firmware updating Consolidation of alarm settings See http www geistgloba...

Page 28: ...cting technical support Figure 28 Web Page Header Firmware Updates Keep your unit updated with the latest firmware releases or sign up for notifications at the following website http www geistglobal c...

Page 29: ...n Monitoring Tab 13 Figure 10 Configuration Diagnostics Tab 14 Figure 11 Configuration Event Log Tab 15 Figure 12 Configuration Admin Tab 16 Figure 13 Network Configuration 17 Figure 14 Time Settings...

Page 30: ...oved By 1 0 10 14 2009 Initial Version BGP JP AK 1 1 7 1 2010 Minor Text Edits BGP 1 2 10 15 2010 RTAFHD3 Information Added BGP 1 3 4 27 2012 Added GT3HD and GTHD CG 1 4 6 22 2012 Changed logo and web...