GEIGER TCU 150 Operation Manual Download Page 3

I. INTRODUCTION

If you need assistance related to this product, please call Delasco at 
800.831.6273 (712.323.3269).

It is important that the instructions supplied with this equipment be read, 
understood, and followed in order to enhance safety and effectiveness.

II. TABLE OF CONTENTS

PRECAUTIONS ........................................................................................ 1
INDICATIONS FOR USE .......................................................................... 2
INSPECTION ............................................................................................ 2
DEVICE DESCRIPTIONS ........................................................................ 2
OPERATING INSTRUCTIONS ................................................................. 4
UNIT CLEANING ...................................................................................... 5
STORAGE ................................................................................................ 5
STERILIZATION OF ACCESSORIES ...................................................... 5
WARRANTY AND REPAIR ....................................................................... 6
SPECIFICATIONS .................................................................................... 6
SYMBOL EXPLANATION ......................................................................... 7
VOLTAGE/CURRENT VS. DIAL SETTING ............................................... 8

III. PRECAUTIONS

CAUTION:

 Federal (U.S.A.) law requires the sale of this device to or on 

the order of a physician or health care professional.

CAUTION:

 This device is supplied non-sterile.

WARNING: 

The risk of igniting flammable gases or other materials is 

inherent in the practice of thermal cautery and cannot be eliminated by 

device design. Precautions must be taken to avoid contact of flammable 

materials and substances with thermal cautery electrodes, whether they 
are in the form of an anesthetic or skin preparation agent, are produced 
by natural processes within body cavities, or originate in surgical drapes, 
tracheal tubes or other materials.

CAUTION: 

Studies have shown that smoke generated during thermal 

cautery procedures may be harmful to surgical personnel. These studies 
recommend using a surgical mask and adequate ventilation of the smoke 
using a smoke evacuator or other means.

1

Summary of Contents for TCU 150

Page 1: ...THERMAL CAUTERY UNIT MODEL 150 OPERATION MANUAL ...

Page 2: ......

Page 3: ...r on the order of a physician or health care professional CAUTION This device is supplied non sterile WARNING The risk of igniting flammable gases or other materials is inherent in the practice of thermal cautery and cannot be eliminated by device design Precautions must be taken to avoid contact of flammable materials and substances with thermal cautery electrodes whether they are in the form of ...

Page 4: ...d undamaged If damage has occurred during shipment or an item is missing contact Delasco directly within ten days of purchase To purchase additional TCU supplies contact your Delasco Distributor or Delasco at 800 831 6273 712 323 3269 VI DEVICE DESCRIPTION Please refer to Figure 1 for the following device descriptions 1 On Off Switch Turns TCU power On and Off 2 Power On Light Illuminates when the...

Page 5: ...utput Settings are from 1 10 and are for reference only 8 Handpiece Activation Button Activation occurs when the blue Hand piece Activation Button on the Handpiece is pressed 9 Handpiece Holder During non use periods the Handpiece may be stored in this holder 3 ...

Page 6: ...rounded power receptacle 5 Turn the Dial Setting Knob counterclockwise to the lowest setting 6 Turn the unit On Off Switch to the On position 7 Press the Handpiece Activation Button and slowly rotate the Dial Setting Knob clockwise When the electrode exhibits a red glow the Cautery Unit is ready for use 8 When the procedure has been completed return the Dial Setting Knob to the lowest setting and ...

Page 7: ...ctrodes may be auto claved according to the instructions below Separate the electrode from the Handpiece prior to autoclaving and use aseptic procedures when handling and sterilizing both items 1 Wipe and remove all debris present on the Handpiece Electrode 2 Place the Handpiece Electrode in an autoclavable pouch or wrapped cloth 3 Steam sterilize for a period of 20 minutes at 250 F 121 C or consu...

Page 8: ... are non refund able except in the case of shipping error on the part of Delasco Please contact Delasco at 800 831 6273 712 323 3269 to obtain a Re turn Authorization Number XII SPECIFICATIONS Line Voltage Model 150 90 130 volts 50 60Hz Model 150A 210 240 volts 50 60Hz Line Current 1 0 Amps Line Frequency 50 60Hz Output Wave Shape Clipped Sinusoidal Output Power 0 30 Watts 6 Watts 0 2 Ohm Load Fun...

Page 9: ... unit Caution Read Operation Manual and directions for use prior to using equipment On power connection to the mains Off power disconnection from the mains Cautery Handpiece Connection Receptacle Figure 2 XIV VOLTAGE CURRENT VS DIAL SETTING Figure 3 contains the voltage and current output of the TCU over the range of dial settings available 7 ...

Page 10: ...8 ...

Page 11: ......

Page 12: ...Delasco LLC 608 13th Avenue Council Bluffs IA 51501 6401 USA Toll Free Phone 800 831 6273 Local Phone 712 323 3269 Toll Free Fax 800 320 9612 www delasco com 81 0018 REV E 03 19 ...

Reviews: