MK4 SErIES – COrrECT uSE OF THE PCur034 FlOaTING CurSOr 

Under standard conditions (Fig. 1), the PCUR034 cursor must be installed on a support made of non-magnetic material 
(such as brass, aluminium, or AISI316 stainless steel). 
The installation kit, consisting of two screws, two nuts, and two washers (all made of brass), is included in the package. 
The cursor (Fig. 2) must be installed with maximum attention to horizontal alignment with the transducer axis (maximum 
tolerance is ± 2 mm), as well as to the distance from the transducer surface from 2 to 7 mm (0 to 7 mm for MK4-S ver-
sion with digital SSI interface). 
If there is no alternative to a magnetic sup-
port, it’s necessary to prevent the support 
from changing the magnetic field generated 
by the cursor, because this could cause pro-
blems with the correct measurement of the 
cursor position.  
For this reason, a non-magnetic spacer 
must be added between the cursor and the 
magnetic support (Fig. 3 - Sol. 1).
The recommended spacer thickness is 15 mm.  
If the application does not permit the instal-
lation of a non-magnetic spacer, it’s possible 
to install the cursor directly on the magnetic 
support, being careful not to let the support 
make direct contact with the part of the cursor 
containing the magnet (Fig. 3 - Sol. 2).
If the application requires instal-
lation of multiple cursors (two or 
more), the cursors must be mini-
mum 75 mm apart (Fig. 4).
Remember that in order to ensu-
re precise measurement, each 
magnet must be installed at the 
same distance from the transdu-
cer surface.  
In addition, all cursors must be 
kept at the same working tempe-
rature.

Fig. 1

Fig. 2

Total length
Total stroke

Support

Cursor

Screws

96

58

max ± 2 mm

2...7 mm

Fig. 4

min 75mm.

Fig. 3

Non-magnetic

Support

Magnetic  

Support

Support 

magnetic

Non-magnetic

spacer

Cursor

Cursor

Cursor

Screws

Screws

Screws

Sol.1

Sol.2

Max

12 mm

Summary of Contents for MK4 Series

Page 1: ...eries Correct use of the PCUR034 floating cursor Pag 3 IK4 SK4 Series Mounting inside a cylinder Pag 4 Instructions for electrical installation of magnetostrictive transducers Pag 5 Details on models with SSI output MK4 S and IK4 S Pag 5 Data Format Pag 5 Error messages Pag 6 Oversampling option Pag 6 Details on models with CANOPEN output MK4 C and IK4 C Pag 7 Diagnostics of models with leds Pag 7...

Page 2: ...ation on the cursor creating problems for sliding Use a floating cursor instead MK4 SERIES CORRECT USE OF INSTALLATION BRACKETS Use PKIT09x brackets to be ordered separately to correctly install the MK4 magnetostrictive transducer Choose the best model based on the material on the attachment holes interaxis and on the dimension of the screws included in the package Each package has two brackets We...

Page 3: ...the correct measurement of the cursor position For this reason a non magnetic spacer must be added between the cursor and the magnetic support Fig 3 Sol 1 The recommended spacer thickness is 15 mm If the application does not permit the instal lation of a non magnetic spacer it s possible to install the cursor directly on the magnetic support being careful not to let the support make direct contact...

Page 4: ...ed sealing surfaces The sealing surface must be free of spiral or longitudinal scratches Ro 1 6 µm for O rings with NON pulsing pressure Ro 0 8 µm for O rings with pulsing pressure Rod type magnetostrictive transducers are always supplied with an O ring If you need to replace the supplied O ring see the O rings shown in figures 6 and 7 SERIE IK4 SK4 INSTALLAZIONE IN INTERNO CILINDRO B Inactive zon...

Page 5: ... Installation of Magnetostrictives The manual and certificates of conformity can be downloaded from the website www gefran com DETAILS ON MODELS WITH SSI OUTPUT MK4 S and IK4 S The diagram shows the operation of a sensor with SSI Synchronous Serial Interface The position of the magnet on the sensor is defined by the signal provided by the sensor using the magnetostrictive technology The displaceme...

Page 6: ...terpolation and are equal to Out M V T M last internal measurement V magnet speed T time elapsed since last measurement The data is supplied to the shift regi ster considering possible Jitter in the controller interrogation time 40 mSec is currently considered Lower Jitter levels ensure better inter polation results see Figure 10 To maintain synchronism between SSI clock and shift register refresh...

Page 7: ...er code on the datasheet Each device connected in the CANopen network must have a unique node number that identifies it Each magnetostrictive transducer is factory programmed with a standard node number of 127 A few changes to the settings of transducers with CANopen output such as node number baud rate etc can be perfor med by connecting them to a CAN master and programming the parameters in the ...

Page 8: ...8 85190A_MAN_Installazione_MK4 IK4 SK4_11 2012_ENG GEFRAN spa via Sebina 74 25050 PROVAGLIO D ISEO BS ITALIA tel 0309888 1 fax 0309839063 Internet http www gefran com ...

Reviews: