8.3 Operator menu and function
Monitor - menu
The status row displays the current status
“0” means no error
Display of the parameter in the Monitor menu
Monitor menu only displayed value
Parameter can be changed from here!
Parameter menu in the positioning menu
Values of the parameter can be changed
if „E“ appears on the status line
Save data in non-volatile memory:
Change the value
savepara
from
0
to
7
in the menu data saving. The saving in the EEPROM will
automaticly be activated. After the finish of the saving the value savepara should be changed back
to 0.
Monitor
.
Freq-Steuerung
Positionierung
Status: 0
Status: 0
Monitor
Drehzahl
1494
1/min
Status: 0
Status: 0
Positionierung
Geschw. V1
19.9
Hz
Status: 0
Status: 0
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0
Art.-No.: 918 111e
Page 51 von 60