7
80588_eView HD IP67_02-2019_ENG
3. TECHNICAL SPECIFICATIONS
Touchscreen technology
Projected capacitive - Multitouch
Back-up battery
3V 7mAh Vanadium-Lithium, rechargeable, not user-replacea ble, model VL1220.
Flash
4GB (8GB for eView HD 156 IP67 and eView HD 215 IP67)
RAM
1GB (2GB for eView HD 156 IP67 and eView HD 215 IP67)
Hardware clock
Clock/Calendar with back-up battery
Accuracy RTC (at 25°C)
<100ppm
ENVIRONMENTAL CONDITIONS
Operating temperature
(surrounding air temperature)
-20 ÷ +55°C (vertical installation)
EN 60068-2-14
Storage temperature
-30 ÷ +80°C (eView HD 101 IP67)
-20 ÷ +70°C (eView HD 156 IP67, eView HD 215 IP67)
EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing
EN 60068-2-30
Vibrations
5 ÷ 9 Hz, 7 mm
9 ÷ 150 Hz, 1 g
EN 60068-2-6
Shock
± 50 g, 11 ms, 3 pulses per axis
EN 60068-2-27
Protection class
IP67 (requires appropriate connectorisand cables)
EN 60529
ELECTROMAGNETIC COMPATIBILITY (EMC)
Radiated disturbance test
Class A
CISPR 22
CISPR 16-2-3
Electrostatic discharge
immunity test
8 kV (air electrostatic discharge)
4 kV (contact electrostatic discharge)
EN 61000-4-2
Radiated, radio-frequency,
electromagnetic field immunity
test
80 MHz ÷ 1 GHz, 10V/m
1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
EN 61000-4-3
Burst immunity test
± 2 KV dc power port
± 1 KV signal line
EN 61000-4-4
Surge immunity test
± 0,5 KV dc power port (line to earth)
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
EN 61000-4-5
Immunity to conducted
disturbances inducted by
radiofrequency field
0.15 ÷ 80 MHz, 10V
EN 61000-4-6
Power frequency magnetic field
immunity test
Enclosure, 50/60Hz, 30A/m
EN 61000-4-8