+4 to disable In and Ou pages
+8 to disable Cf page
+32 base configuration (the following parameters will not be displayed:
In: FI, L_L, H_L
Ou: On [forced to no. outputs present])
ON = 100Hz filter
• Protection
Protection code
Value
Displayed
Modifiable
parameters
parameters
0
o.1, o.2, o.3
o.1, o.2, o.3
1
o.1, o.2
o.1, o.2
2
o.1
o.1
3
o.1
none
P r
• Output parameters
Main input filter
Input settings
With FP = 0 or 2: Period corresponds to
minimum frequency in input
With FP = 1 or 3: Sampling time,
TC = 0 update after 32 sec.
0.0 ... 10.0sec
Max. frequency
Prescaler
in input
ratio
0
1KHz
1
1
2KHz
2
2
4KHz
4
3
10KHz
2
4 (*)
20KHz
4
5 (*)
40KHz
8
6 (*)
80KHz
16
7 (*)
100KHz
32
ON / OFF
Value
Direct
Absolute
Normal
(max.) Relative
to
Symmetrical
Inverse
previous
(window)
(min.)
0
Direct
Absolute
Normal
1
Inverse
Absolute
Normal
2
Direct
Relative
Normal
3
Inverse
Relative
Normal
4
Direct
Absolute
Symmetrical
5
Inverse
Absolute
Symmetrical
6
Direct
Relative
Symmetrical
7
Inverse
Relative
Symmetrical
Output settings
Number of outputs
0 to 3
1. t - 2. t - 3. t
+8 to disable on power-up until first alarm
+16 to memorize
+32 to filter with F.O. mode (output filter mode)
Divisor
Selection of full scale
frequency
1 ... 255
O u
Alarm type 1
Alarm type 2
Alarm type 3
Multiplier
1 ... 255
In
Decimal point position for
full scale
dP
Format
0
XXXX
1
XXX.X
2
XX.XX
3
X.XXX
0
None
1
Zero
2
Hold
3
Flash
4
Max. peak display
5
Min. peak display
6
Delta peak display
7
Peak memory reset
8
Zero + peak
memory reset
9
Alarms reset
10 Peak + alarms reset
11 Zero + alarms
reset
12 Peak + zero +
alarms reset
13 Output status OUT1
14 Output status OUT2
15 Output status OUT3
Low limit for the alarms
set point
-1999 ... 9999
High limit for the alarms
set point
-1999 ... 9999
Minimum scale analog
repeat output
-1999 ... 9999
Maximum scale analog
repeat output
-1999 ... 9999
• Input parameters
+8 enable MU, dE parameters
(*) value shown indicates frequency /10 see
application example
delay for F.O.
0 to 99 min or sec
Minimum output pulse
0 to 99 sec
Disabled by setting value 0
Displayed if associated with at least one output
Output filter mode
0 not active: calculated status
is sent directly to relay
1 On delay (DON)
2 delay activation from
time of deactivation
of output (DBI)
3 Off delay (DOF)
4 Delay for activation
only at power-up
(DPO)
+ 8 time base max. 99 min (default = 99 sec)
Selection of digital
input 1
Raise key function
(active only in
P.V.selection)
Lower key function
(active only in
P.V.selection)
0 Frequency - input NPN
1 Frequency - input PNP
2 AC input
Input
configuration
0 Normal frequency value
1 Settable sampling time
2 Normal frequency value
with fixed full scale
3 Sampling time settable
with fixed full scale
Frequency meter
operating mode
• User Calibration
U.C. CPU F Function
1
analog retransmission
output
U. C.
Calibration of
minimum (*)
Calibration of
maximum (*)
(*) when U.C. = 1 press keys
∆ ∇
to calibrate
analog output
Determines full scale of retransmitted output and alarms
N.B.: valid only for frequencies with fixed full scale;
automatic shift of Dp for higher frequencies
4