7
Remote Channel 1:
Default
1 2
Remote Channel 2:
1 2
Remote Channel 3:
1 2
Remote Channel 4:
1 2
Remote Channel 1:
Default
1 2
Remote Channel 2:
1 2
Remote Channel 3:
1 2
Remote Channel 4:
1 2
RMT-16-IR REMOTE CONTROL
4x4 DVI DL Matrix
1
2
3
4
5
6
7
8
OFF
ON
The 4x4 DVI DL Matrix has
a bank of 8 configuration
DIP SWITCHES
. These
switches are located underneath the unit. Peeling back the black metallic sticker
on the bottom of the
4x4 DVI DL Matrix will reveal the Dip Switch bank. These
service switches are used for a number of configuration options. By default, all
Dip Switches are in the OFF position. Each setting is outlined below.
Switch 1
IR Remote Channel Configuration
Switch 2
IR Remote Channel Configuration
Switch 3
Automatic Link Selection \ Dual Link Only Mode
Switch 4
Not Used
Switch 5
Pre-Empahsis For Display Output 1
Switch 6
Pre-Empahsis For Display Output 2
Switch 7
Pre-Empahsis For Display Output 3
Switch 8
Pre-Empahsis For Display Output 4
IR REMOTE CHANNEL CONFIGURATION
Dip Switches 1 and 2 relate to the IR remote control channel that is used by the
4x4
DVI DL Matrix and RMT-16-IR remote control. Dip Switch 1 and 2 on the 4x4
DVI DL Matrix must match Dip Switch 1 and 2 on the RMT-16-IR remote control.
Please view the table below to set the channel on 4x4 DVI DL Matrix and IR
remote control. The remote channel for the RMT-16-IR is located underneath it’s
battery cover.
CONFIGURING THE 4X4 DVI DL MATRIX