Step 5
Ignition switch is at "ON" position, does relay 85 terminal have 12V voltage?
No
Replace the starter. Confirm whether the fault
has been fixed.
Yes
Step 6
Check starter relay terminal No.85 voltage
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect the ignition switch wiring harness connector IP23.
(c)
Measure starter relay terminal No.85 voltage, whether there
is 12V voltage?
No
Replace the ignition switch.
Yes
Step 7
Circuit between the ignition switch wiring harness connector IP23 and starter relay terminal No.85 is short
to power supply. Repair the faulty part.
Next
Step 8
Diagnostic completed.
2.11.7.4 Engine Can Not Start
Prior to the implementation of this test procedure, it is necessary to check all the starting system fuses, so that it will help with quick
Diagnostic.
Step 1
Verify the fault.
Next
Step 2
Does the engine run?
No
Yes
Step 3
Does the engine run properly?
No
Yes
Step 4
Check ignition / fuel system. Refer to
Crankshaft rotates, but the engine can not start.
.
Step 5
Check the starter motor power supply.
Check the following:
(a)
Whether the battery capacity is normal, whether the starting
voltage is lower than 10.5V, otherwise recharge the battery.
2-560
Starting / Charging System JL4G18-D
Engine
EC718/EC718RV EC715/EC715RV 10/2009
Summary of Contents for EC715 2009
Page 4: ......
Page 330: ...Next Step 10 End 2 248 Fuel System JL4G18 D Engine EC718 EC718RV EC715 EC715RV 10 2009 ...
Page 1164: ......
Page 2008: ......