background image

To unlock the keypad:

1- Enter the programming mode by 

pressing the 

Program 

key. "Loc" is 

displayed.

2- Press 

Up 

arrow key.

3- Press 

Pump 1 

key.

4- Press 

Light 

key.

The "Lock" icon will disappear and the spa side control will 
return to normal mode.

If the unlock process takes more than 15 seconds, the spa 
side control will return to normal mode but the keypad will 
remain locked.

Loc

1

The system automatically performs two filter cycles per day, 
at 12-hour intervals. During a filter cycle, Pump 2 & blower 
run for one minute, then Pump 1 runs at low speed for the 
programmed number of hours. The ozonator is also acti-
vated and "Filter Cycle" icon is on.

To program a filter cycle, you must enter two parameters: 
the start time of the cycle and its duration. If no filtering is 
required, the duration must be set to "OFF". If continuous 
filtering is required, the duration must then be set to "12:00".

To set the start time of the cycle:

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Filter cycle

 

start 

parameter 

by pressing the 

List

 key until "FIon" 

is displayed.

3- Press 

Enter

 key to display the

current setting.

4- Use 

Up 

or

 Down

 arrow key

 

to 

change setting.

5- Press 

Enter 

key to confirm the 

new setting.

The spa side control will return to normal mode.

To set the duration of the cycle:

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Filter cycle duration 

parameter by pressing the 

List

 key 

until "FIdu" is displayed.

3- Press 

Enter 

key to display the

current setting.

4- Use 

Up 

or

 Down

 arrow key

 

to 

change setting.

5- Press 

Enter 

key to confirm the 

new setting.

The spa side control will return to normal mode.

Water temperature can be displayed in ˚F or ˚C. 

To select the temperature display unit:

 

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Temperature unit

 pa-

rameter by pressing the 

List 

key 

until "Tu" is displayed.

3- Press 

Enter 

key to display the

current setting.

4- Use 

Up 

or 

Down 

arrow key to 

change setting.

5- Press 

Enter 

key to confirm the 

new setting.

The spa side control will return to normal mode.

FIon

10:15

11:30

CL

FIdu

1:00

2:00

CL

Filter cycle start time & duration

Temperature unit

C

F

Tu

1

2

2

1

2

2

CL

1

2

2

Keypad lockout

This function allows you to prevent unauthorized parameter 
setting of the unit. The basic functions of the spa will remain 
accessible (pump, blower and light outputs) but it will be 
impossible to change the temperature Set Point, to override 
the Economy mode or to enter the programming mode. 

When the keypad is locked, the "Lock" icon will be displayed.

To lock the keypad:

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Keypad lockout

 parameter 

by pressing the 

List 

key until "Loc"

 

is displayed.

3- Press 

Enter 

key to display the

current setting.

4- Use 

Up 

or 

Down 

arrow key to 

change setting.

5- Press 

Enter 

key to confirm the 

new setting.

The spa side control will return to normal mode, with keypad 
locked, and the "Lock" icon will be displayed.

On

OFF

Loc

CL

1

2

2

Economy mode start time & duration

Time of day

CL

2:20 

pm

4:30 

pm

The Economy mode allows you to lower the temperature 
Set Point of the spa by 20˚F (11˚C) during a certain period 
of the day. When in Economy mode, the "Economy Mode" 
icon will be displayed.

To program the Economy mode, you must enter two 
parameters: the start time and the duration. If the Economy 
mode is not required, the duration must be set to "OFF".

You can manually override the current Economy status (on 
or off) for the rest of the day by pressing the 

Mode

 key.

To set the start time of the Economy mode:

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Economy mode start

 

parameter by pressing the 

List 

key until "ECon" is displayed.

3- Press 

Enter 

key to display the

current setting.

4- Use 

Up 

or 

Down 

arrow key to 

change setting.

5- Press 

Enter

 key to confirm the 

new setting.

The spa side control will return to normal mode.

To set the duration of the Economy mode:

1- Enter the programming mode by 

pressing the 

Program 

key.

2- Select the 

Economy mode duration

parameter by pressing the 

List 

key 

until "ECdu" is displayed.

3- Press 

Enter 

key to display the

current setting.

4- Use 

Up 

or 

Down 

arrow key to 

change setting.

5- Press 

Enter

 key to confirm the 

new setting.

The spa side control will return to normal mode.

This function allows you to set the internal clock of the 
system.
 
The unit will keep time in memory for about 48 hours in 
case of power failure.

To set the time:

1- Enter the programming mode by 

pressing the 

Program 

key. "CL" is

displayed.

2- Press 

Enter 

key to display the

current setting.

3- Use 

Up 

or 

Down 

arrow key to 

change setting.

4- Press 

Enter

 key to confirm the 

new setting.

The internal clock will be adjusted and the spa side control 
will return to normal mode.

11:00 

pm

10:00 

pm

ECon

CL

8:00

4:00

ECdu

CL

1

2

2

1

2

2

2

2

Filter Cycle

icon

Lock

icon

Economy Mode

icon

Temperature

unit

Program

key

Program Mode

icon

Enter

key

List

key

PROGRAMMING INSTRUCTIONS

Parameter summary

CL

Time of day

Flon

Filter cycle start

FIdu

Filter cycle duration

ECon

Economy mode start

ECdu

Economy mode duration

Tu

Temperature unit (˚F or ˚C)

Loc

Keypad lockout

9919-100058-C

1.800.78.GECKO

• E

Q U

I P P

E D W

I T H G E C K O ' S E X C L

U S I V

E •

Smart

Winter