Troubleshooting

Pumps have started up 

for one minute on several

occasions and "Filter Cycle"

icon is flashing.

Not a bug but a feature!

Our 

Smart Winter Mode

protects your system from

the cold by automatically

turning the pumps on for

one minute several times a

day to prevent water from

freezing in pipes.

Water temperature is

displayed.

Water temperature in the

spa has reached 112˚F

(44˚C).

Do not enter the water!

Allow water to cool down.

The system will reset au-

tomatically when water

reaches 109˚F (43˚C).

Call your dealer or service

supplier if problem persists.

3 flashing dots are 

displayed.

A problem has been 

detected.

Do not enter the water!

Check and open water

valves. Clean filters if nec-

essary. Check water level.

Add water if needed.

Shut power off and power

your spa up again to reset

the system.

Call your dealer or service

supplier if problem persists.

The display is flashing.

A power failure has

occurred. Press any key

to reset the system, then

reprogram all desired

parameters.

Use 

Up

 or 

Down

 arrow key to 

regulate water temperature. 

The temperature setting will be 

displayed for 5 seconds to confirm 

your new selection.
The "Set Point" symbol indicates the 

desired temperature, NOT the 

current water temperature!
Water temperature can be adjusted 

by 1˚ increments from 59˚ to 104˚F 

(15˚ to 40˚C).

Setting water temperature:

When water temperature is 1˚F (0.5˚C) 

lower than the Set Point, the heater will 

automatically turn on until water 

tempera-ture reaches Set Point plus 1˚F 

(0.5˚C).

 

The "Heater" icon lights up when  

 

 the heater is o . It flashes when    

 there is a request for more heat   

            but the heater has not yet started.

Automatic water heater start:

Press and hold 

Light 

key for 5 seconds to 

display water temperature in either 

Fahr-enheit (˚F) or Celsius (˚C).

Temperature display unit:

The display toggles every 5 seconds 

alter-nately showing the hourly time and the 

current water temperature.

Time & temperature display:

Press 

Pump 1

 to turn Pump 1 on at 

low speed. Pressing a second time 

turns Pump 1 to high speed. A third 

time turns Pump 1 off. When at high 

speed, a built-in timer turns pump off 

after 20 minutes and when at low 

speed after 2 hours, unless it has 

been manually deactivated.
The "Pump 1" icon lights up when 

Pump 1 is on at high speed. It flashes 

when Pump 1 is on at low speed.

Starting Pump 1:

Starting Pump 2:

Press 

Pump 2

 once to turn Pump 2 

on at low speed. Pressing a second 

time turns Pump 2 to high speed. 

A third time turns pump off. A built-in 

timer turns pump off after 20 

minu-tes, unless manually deactivated 

first.
The "Pump 2" icon lights up when 

Pump 2 is on at high speed. It flashes

when Pump 2 is on at low speed.

The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above 

Set Point or if a pump has been started manually. The "Filter" icon will blink (on 0.5 second, 

off 0.5 second, on 0.5 second, off 1.5 seconds).

Press 

Pump 3

 to turn Pump 3 on. 

Pressing a second time turns Pump 3 

off. A built-in timer automatically turns 

pump off after 20 minutes, unless 

manually desactivated first.
The "Pump 3" icon lights up when 

Pump 3 is on.

Starting Pump 3:

Inverted display:

Press and hold 

Pump 2 

for 5 seconds to invert 

the display. Note that the ˚F or ˚C icon is not 

displayed in reverse mode. Follow the same 

procedure to return to default mode. 

If a power-up occurs, the display always 

returns to default mode.

MC-MP Spa Pack

 

Pressing 

Light

 key once turns light on. Pressing a second time turns light off.

 

A built-in timer turns light off after 2 hours, unless it has been manually deactivated.

 

  

The "Light" icon is displayed 

 

  

when light is on.

LED Light Option: 

If spa has an optional LED light, Press 

Light

 key to turn LED lights on. 

To advance to the next color/display setting, press 

Light

 key twice. The LEDs will go off with 

the first press, then back on in the next setting with the second press. If the LEDs remain off for 

more than 5 sec., the color/display sequence will reset and start back at the beginning the next 

time the 

Light 

key is pressed. Color/ display sequences are:

1• LEDs light up and slowly cycle through all  

  six colors. The slow cycle restarts at the  

    beginning and repeats.
2• LEDs light up and remain on in Aqua.
3• LEDs light up and remain on in Purple.
4• LEDs light up and remain on in Blue.
5• LEDs light up and remain on in Gold.
6• LEDs light up and remain on in Green.

7• LEDs light up and remain on in Red.
8• LEDs light up for 2 sec., flash off, then 

  flash on in the next color until all six colors 

  have been displayed. The flashing cycle 

  then repeats itself.
9• LEDs flash on/off quickly for a strobe light 

  effect. A built-in timer turns lights off after 

  2 hours unless manually deactivated first.
 

The "Light" icon is displayed 

 

when light is on.

Turning the light on:

Reviews: