Filter cycle frequency
Press
Light
key again. The display will show
Fx
, with "x"
representing the number of filter cycles per day (up to 4).
(Default: twice a day).
Use
Up
or
Down
key to change setting.
When the desired setting is displayed, press
Light
key
to confirm. A filter cycle will start immediately.
The “Filter” indicator lights up
when a filter cycle is on.
Purge cycle frequency
Press and hold
Light
key until the display shows
Fx
, with "x"
representing the number of purge cycles per day (up to 4).
Use
Up
or
Down
key to change setting.
When the desired setting is displayed, press
Light
key to confirm. A purge cycle will start immediately.
The “Filter” indicator lights up
when a purge cycle is on.
Programming purge cycles
To program the purge cycles, you must select the frequency. During a purge cycle, all pumps
and the blower run for one minute. To set purge cycles:
Water temperature regulation
In a regulation cycle, the system first gener-
ates water flow through the heater housing
and the plumbing, in order to ensure accu-
rate water temperature readings as well as
avoiding heater activation in dry conditions.
After verifying pump activation and taking a
water temperature reading if required, the
system automatically turns the heater on to
reach and maintain water temperature at
Set Point.
The “Heater” indicator lights up when
the heater is on. It flashes when there
is a request for more heat but the
heater has not yet started.
Cooldown
While performing this task, the heater is not
allowed to turn on and its icon flashes.
Smart Winter Mode
Our Smart Winter Mode protects your
system from the cold by turning pumps on
several times a day to prevent water from
freezing in pipes.
The “Smart Winter Mode” indicator
lights up when the Smart Winter Mode
is on.