background image

 10

in.terface

Dry contact switch

If you use dry contact switches, 

you need to connect them 

in the white "AC" enclosure 

keyings.

Up to 2 loads per connector is 

possible for a maximum of  

4 different loads.

Wires of cables determine 

switch's functionality.

P1

Light

in.xm

(or any Aeware spa pack)

P1

P3

P2

Light

Auxiliary keypad in.terface (Con't)

connections

Summary of Contents for Aeware in.terface

Page 1: ......

Page 2: ...1 in terface Table of contents overview 3 installation 6 connections audio video in terface 8 aux keypad in terface 9 powering the unit 11 speci cations 12 table of contents...

Page 3: ...Aeware spa systems UL CSA CE approved in terface is available in 2 con gurations Audio video in terface is used to control Aeware s in tune receiver cd player or in pix dvd cd player from in k600 seri...

Page 4: ...4 in terface overview To spa pack Fastening bracket CO enclosure keyings AU enclosure keyings Audio video in terface...

Page 5: ...5 in terface overview To spa pack Fastening bracket C enclosure keyings Aux keypad in terface AC enclosure keyings...

Page 6: ...terface The unit must be installed under the spa skirt in the upright position to ensure watertightness We recommend that you install the unit with 8 PAN head screws See the illustration above install...

Page 7: ...155 to the in terface Optional purple CO enclosure keyings are used to connect DJS 1 SpaWatch or Pocket tek ADIR II cartridge in pocket Connect the in terface to the Aeware spa pack in xm purple CO co...

Page 8: ...se the in k100 in k400 or streamlined interface version of the in k600 you need to connect the keypads in the orange C enclosure keyings of the in terface Note that only one type of single con guratio...

Page 9: ...yings of the in terface Connector position determines switch s functionality Customized functionality is possible Contact us for more details You can connect up to 5 single switches to the in terface...

Page 10: ...to connect them in the white AC enclosure keyings Up to 2 loads per connector is possible for a maximum of 4 different loads Wires of cables determine switch s functionality P1 Light in xm or any Aew...

Page 11: ...n terface to the Aeware spa pack in xm But if you use the auxiliary keypad in terface you will need to reset the Aeware spa pack in xm after completion of the installation Note Before powering the Aew...

Page 12: ...to 85 non condensing operating temp 25 C to 60 C Storage temp 30 C to 85 C Speci cations and design are subject to change without prior notice speci cations Standards UL 1563 Fifth Ed CSA No 22 2 218...

Page 13: ...Advanced electronics Water resistance GeckoAlliance 450desCanetons QuebecCity QC G2E5W6Canada 1 800 78 GECKO 9225StellarCourt Corona CA92883USA 951 667 2000 www geckoalliance com 9919 100722 Rev 05 07...