System connection
The communication cable provided with the heat pump must be connected to the RS485 communication port of the
spa control
The power cable connects to the spa control using 6,35mm (0,250'') quick connect female terminals Ensure that all
female terminals are correctly and completely seated on the printed circuit terminals for proper current ratings
The connection must be done according to the following tables:
External breaker
The intemp is intended to be powered by the spa control using the included power cable but it can also be powered by
an external circuit breaker
If an external circuit breaker is used to power the intemp, make sure the cord used comply with all local regulation
To avoid unnecessary shedding of accessories when the intemp or a different heat pump is not powered by the spa
control, set the heat pump current to zero (0) through your spa user interface
Terminal box
The terminal box is located behind the terminal cover and allows access to the communication and power connections
Connections
Turn off power before connecting the intemp to the spa control system
CE Model
Brown
Main line P28, P30 or P32 tab (F2)
Blue
Any Neutral (N) tab
Green/Yellow
Any Ground (G) tab
NA* Model
Black
Main line P31, P33 or P36 tab (F3)
White
Any Line 2 (L2) tab
Green
Any Ground (G) tab
P28-P30-P32
P31-P33-P36
in.ye control system
Neutral (N), L2 and Ground (G) tabs
Communication cable
Communication cable
RS485 port (P83)
Power cable (CE)
Power cable (NA*)
Terminal ID
Brown
Red Black Green White
Blue Green/
Yellow
Wire color
Signal
220 V~240 V, 50 Hz
12V
RS-485
L
+
-
B
A
N
Terminal ID
Black
Red Black Green
Green
White
White
Wire color
Signal
240 V ± 5%, 60 Hz
12V
RS-485
L
+
-
B
A
N
*North American
Summary of Contents for 0615-807000
Page 5: ......